Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr SiemensPower_SiemensPower.Components.SolidComponents.Tests.wall_test.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo", uses=false) Using package SiemensPower with version 2.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(SiemensPower.Components.SolidComponents.Tests.wall_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.SolidComponents.Tests.wall_test") translateModel(SiemensPower.Components.SolidComponents.Tests.wall_test,tolerance=1e-06,outputFormat="empty",numberOfIntervals=1000,variableFilter="",fileNamePrefix="SiemensPower_SiemensPower.Components.SolidComponents.Tests.wall_test") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.01179/0.01179, allocations: 100.6 kB / 15.73 MB, free: 6.043 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001843/0.001843, allocations: 190 kB / 16.67 MB, free: 5.977 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 2.058/2.058, allocations: 205.1 MB / 222.5 MB, free: 4.484 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/package.mo): time 0.03054/0.03054, allocations: 5.573 MB / 275.5 MB, free: 15.59 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: SiemensPower requested package Modelica of version 3.2.1. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001518/0.001518, allocations: 74.25 kB / 383.3 MB, free: 11.87 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.4007/0.4022, allocations: 47.87 MB / 431.2 MB, free: 9.285 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/SiemensPower 2.2.0/Components/SolidComponents/Tests/wall_test.mo:6:5-7:32:writable] Error: Modified element considerAxialHeatTransfer not found in class Wall. Notification: Performance of FrontEnd: time 0.001914/0.4042, allocations: 401.3 kB / 431.5 MB, free: 9.059 MB / 318.1 MB