Environment - simulationEnvironment: startTime=0 stopTime=4e-06 tolerance=1e-08 numberOfIntervals=1999 stepSize=2.001e-09 Regular simulation: ./ScalableTestSuite_ScalableTestSuite.Electrical.TransmissionLine.ScaledExperiments.TransmissionLineEquations_N_320 -s=ida -abortSlowSimulation -alarm=300 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0195798s reading init.xml | | | | | | 0.00114662s reading info.xml | | | | | | 0.000743604s [ 0.2%] pre-initialization | | | | | | 0.000297448s [ 0.1%] initialization | | | | | | 9.6321e-05s [ 0.0%] steps | | | | | | 0.233147s [ 57.8%] solver (excl. callbacks) | | | | | | 0.0104266s [ 2.6%] creating output-file | | | | | | 0.000404472s [ 0.1%] event-handling | | | | | | 0.00118343s [ 0.3%] overhead | | | | | | 0.15697s [ 38.9%] simulation | | | | | | 0.403269s [100.0%] total | | | | | events | | | | | | 1 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 7911 steps taken | | | | | | 8007 calls of functionODE | | | | | | 42 evaluations of jacobian | | | | | | 1 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00378829s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.