Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Modelica_3.1_Modelica.Electrical.Analog.Examples.ControlledSwitchWithArc.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.02758/0.02758, allocations: 104.1 kB / 17.47 MB, free: 4.84 MB / 14.72 MB [Timeout remaining time 90] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001222/0.001222, allocations: 193.9 kB / 20.63 MB, free: 1.695 MB / 14.72 MB [Timeout remaining time 90] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 90] Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.76/1.76, allocations: 207.6 MB / 231.2 MB, free: 3.289 MB / 174.1 MB [Timeout remaining time 88] Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Modelica.Electrical.Analog.Examples.ControlledSwitchWithArc,tolerance=1e-06,outputFormat="empty",numberOfIntervals=24000,variableFilter="",fileNamePrefix="Modelica_3.1_Modelica.Electrical.Analog.Examples.ControlledSwitchWithArc") translateModel(Modelica.Electrical.Analog.Examples.ControlledSwitchWithArc,tolerance=1e-06,outputFormat="empty",numberOfIntervals=24000,variableFilter="",fileNamePrefix="Modelica_3.1_Modelica.Electrical.Analog.Examples.ControlledSwitchWithArc") [Timeout 660] Thread is still alive. OMC died, but the thread is still running? This will end badly. The log-file of omc: Created ZeroMQ Server. Dumped server port in file: /tmp/openmodelica.hudson.port.caa7c8d0e9e84f3990eff9f6c78695fcKilled Aborted the command. [Calling os._exit(0)]