Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode") translateModel(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.009559/0.009559, allocations: 101.2 kB / 15.73 MB, free: 6.043 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001669/0.001669, allocations: 186.2 kB / 16.67 MB, free: 5.973 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.715/1.715, allocations: 205.1 MB / 222.6 MB, free: 4.508 MB / 174.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.05919/0.05919, allocations: 10.73 MB / 280.6 MB, free: 10.43 MB / 238.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001952/0.001952, allocations: 71.89 kB / 390.8 MB, free: 5.039 MB / 286.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.3452/0.3472, allocations: 49.01 MB / 439.9 MB, free: 5.355 MB / 318.1 MB Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode): time 0.00605/0.3533, allocations: 3.205 MB / 443.1 MB, free: 3.062 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may not be used in an algorithm section (use translation flag --allowNonStandardModelica=reinitInAlgorithms to ignore). Notification: Performance of FrontEnd: time 0.0004566/0.3538, allocations: 183.5 kB / 443.2 MB, free: 2.938 MB / 318.1 MB