Environment - simulationEnvironment: startTime=0 stopTime=86400 tolerance=1e-06 numberOfIntervals=2500 stepSize=34.56 Regular simulation: ./Buildings_latest_Buildings.Fluid.HydronicConfigurations.ActiveNetworks.Examples.InjectionTwoWayVariable -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.etaHyd, has value: -1.55709e-138" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= pum.pumSpe.eff.yMot, has value: -6.16468e-136" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((con.pum.pumSpe.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.etaHyd, has value: -3.71286e-151" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa.loa.coi.SHR >= 0.0 and loa.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa.loa.coi.SHR <= 1.0, has value: -6.61528e-181" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:71:3-76:35:writable] | | | | The following assertion has been violated at time 79246.080000 | | | | ((loa1.loa.coi.SHR >= 0.0 and loa1.loa.coi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= loa1.loa.coi.SHR <= 1.0, has value: -1.05319e-175" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.0.0-master/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:313:3-317:28:writable] | | | | The following assertion has been violated at time 79315.200000 | | | | ((con.pum.pumSpe.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= con.pum.pumSpe.eff.yMot, has value: -1.08588e-131" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0894283s reading init.xml | | | | | | 0.00863718s reading info.xml | | | | | | 0.00278902s [ 0.6%] pre-initialization | | | | | | 0.00155597s [ 0.4%] initialization | | | | | | 0.000128321s [ 0.0%] steps | | | | | | 0.018269s [ 4.2%] solver (excl. callbacks) | | | | | | 0.00966136s [ 2.2%] creating output-file | | | | | | 0.00290158s [ 0.7%] event-handling | | | | | | 0.0296532s [ 6.8%] overhead | | | | | | 0.370405s [ 85.1%] simulation | | | | | | 0.435363s [100.0%] total | | | | | events | | | | | | 10 state events | | | | | | 4 time events | | | | | solver: dassl | | | | | | 2947 steps taken | | | | | | 4695 calls of functionODE | | | | | | 676 evaluations of jacobian | | | | | | 244 error test failures | | | | | | 29 convergence test failures | | | | | | 0.129067s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.