Environment - simulationEnvironment: startTime=0 stopTime=604800 tolerance=1e-06 numberOfIntervals=2500 stepSize=241.92 Regular simulation: ./Buildings_latest_Buildings.Examples.HydronicHeating.TwoRoomsWithStorage -abortSlowSimulation -alarm=480 -emit_protected -lv LOG_STATS LOG_STDOUT | warning | The default linear solver fails, the fallback solver with total pivoting is started at time 0.000000. That might raise performance issues, for more information use -lv LOG_LS. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (fanSup.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fanSup.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in TwoRoomsWithStorage.fanSup: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fanSup.per.haveWMot_nominal or not (fanSup.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fanSup.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in TwoRoomsWithStorage.fanSup: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (fanRet.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or fanRet.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in TwoRoomsWithStorage.fanRet: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((fanRet.per.haveWMot_nominal or not (fanRet.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or fanRet.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in TwoRoomsWithStorage.fanRet: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/ThermalZones/Detailed/BaseClasses/InfraredRadiationGainDistribution.mo:19:3-21:73:writable] | | | | The following assertion has been violated at time 2782.080000 | | | | ((roo1.irRadGai.JOutConExtWin[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= roo1.irRadGai.JOutConExtWin[1], has value: -0.000629367" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/ThermalZones/Detailed/BaseClasses/InfraredRadiationGainDistribution.mo:19:3-21:73:writable] | | | | The following assertion has been violated at time 2782.080000 | | | | ((roo1.irRadGai.JOutConExtWin[2] >= 0.0)) --> "Variable violating min constraint: 0.0 <= roo1.irRadGai.JOutConExtWin[2], has value: -0.000419578" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:99:3-99:89:writable] | | | | The following assertion has been violated at time 19653.373261 | | | | ((pumBoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumBoi.etaHyd, has value: -1.15197e-26" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 19653.373261 | | | | ((pumBoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= pumBoi.heaDis.etaHyd, has value: -1.01826e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/ThermalZones/Detailed/BaseClasses/InfraredRadiationGainDistribution.mo:19:3-21:73:writable] | | | | The following assertion has been violated at time 25200.000003 | | | | ((roo2.irRadGai.JOutConExtWin[1] >= 0.0)) --> "Variable violating min constraint: 0.0 <= roo2.irRadGai.JOutConExtWin[1], has value: -0.0669202" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.0.1-master/ThermalZones/Detailed/BaseClasses/InfraredRadiationGainDistribution.mo:19:3-21:73:writable] | | | | The following assertion has been violated at time 25200.000003 | | | | ((roo2.irRadGai.JOutConExtWin[2] >= 0.0)) --> "Variable violating min constraint: 0.0 <= roo2.irRadGai.JOutConExtWin[2], has value: -0.0669202" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.275334s reading init.xml | | | | | | 0.0225333s reading info.xml | | | | | | 0.00960891s [ 0.1%] pre-initialization | | | | | | 0.0464184s [ 0.6%] initialization | | | | | | 0.000390111s [ 0.0%] steps | | | | | | 0.192836s [ 2.6%] solver (excl. callbacks) | | | | | | 0.0566577s [ 0.8%] creating output-file | | | | | | 1.6253s [ 21.8%] event-handling | | | | | | 0.0756308s [ 1.0%] overhead | | | | | | 5.44983s [ 73.1%] simulation | | | | | | 7.45667s [100.0%] total | | | | | events | | | | | | 120 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 12590 steps taken | | | | | | 17657 calls of functionODE | | | | | | 2190 evaluations of jacobian | | | | | | 456 error test failures | | | | | | 7 convergence test failures | | | | | | 3.8544s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.