Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_8_Buildings.ThermalZones.EnergyPlus.Examples.SmallOffice.Unconditioned -abortSlowSimulation -alarm=480 -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.5.0-e579c2aa82 (No OpenGL), YMD=2024.03.13 00:12 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-ATTIC-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-CORE_ZN-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_1-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_2-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_3-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: GetInternalHeatGains: People="SPAWN-ZONE-PERIMETER_ZN_4-RADIANTGAINS", Activity Level Schedule Name values LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: fall outside typical range [70,1000] W/person for Thermal Comfort Reporting. LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Odd comfort values may result; Schedule="SPAWN-PEOPLEACTIVITY-SCHEDULE". LOG_STDOUT | info | 0.000 Unconditioned.flo.building: Warning from EnergyPlus: Entered min/max range=[1.0,] W/person.1.0 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14:3-14:71:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flo.leaSou.amb.CpAct >= 0.0)) --> "Variable violating min constraint: 0.0 <= flo.leaSou.amb.CpAct, has value: -0.307955" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14:3-14:71:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flo.leaEas.amb.CpAct >= 0.0)) --> "Variable violating min constraint: 0.0 <= flo.leaEas.amb.CpAct, has value: -0.376744" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14:3-14:71:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((flo.leaNor.amb.CpAct >= 0.0)) --> "Variable violating min constraint: 0.0 <= flo.leaNor.amb.CpAct, has value: -0.307955" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Sources/Outside_CpLowRise.mo:14:3-14:71:writable] | | | | The following assertion has been violated at time 22222.080000 | | | | ((flo.leaWes.amb.CpAct >= 0.0)) --> "Variable violating min constraint: 0.0 <= flo.leaWes.amb.CpAct, has value: -0.00288618" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0357825s reading init.xml | | | | | | 0.00248698s reading info.xml | | | | | | 0.000124023s [ 0.0%] pre-initialization | | | | | | 1.09387s [ 50.7%] initialization | | | | | | 2.4486e-05s [ 0.0%] steps | | | | | | 0.0261547s [ 1.2%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.268096s [ 12.4%] event-handling | | | | | | 0.0176044s [ 0.8%] overhead | | | | | | 0.751944s [ 34.8%] simulation | | | | | | 2.15782s [100.0%] total | | | | | events | | | | | | 287 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 7089 steps taken | | | | | | 10678 calls of functionODE | | | | | | 4641 evaluations of jacobian | | | | | | 58 error test failures | | | | | | 362 convergence test failures | | | | | | 0.516327s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 00min 1.56sec EnergyPlus Completed Successfully.