Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo", uses=false) Using package Buildings with version 3.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo) Running command: translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") translateModel(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM,tolerance=1e-08,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="Buildings_3.0.0_Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM") [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:257:38-257:110:writable] Warning: The file was not encoded in UTF-8: "

An important practical aspect of state machines is the abilit...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:761:36-761:108:writable] Warning: The file was not encoded in UTF-8: "

The Modelica_StateGraph2 library is described in detail in (O...". Defaulting to 7-bit ASCII with unknown characters replaced by '?'. To change encoding when loading a file: loadFile(encoding="ISO-XXXX-YY"). To change it in a package: add a file package.encoding at the top-level. Note: The Modelica Language Specification only allows files encoded in UTF-8. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.0.2/package.mo:1435:36-1435:108:writable] Warning: The file was not encoded in UTF-8: "

Main Authors:
SCode: time 0.2148/0.2175, allocations: 80.84 MB / 0.6706 GB, free: 4.625 MB / 0.5137 GB Notification: Performance of NFInst.instantiate(Buildings.HeatTransfer.Examples.ConductorSingleLayerPCM): time 0.00673/0.2243, allocations: 4.426 MB / 0.6749 GB, free: 172 kB / 0.5137 GB Notification: Performance of NFInst.instExpressions: time 0.00573/0.2301, allocations: 2.739 MB / 0.6776 GB, free: 13.42 MB / 0.5294 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.0008579/0.231, allocations: 15.94 kB / 0.6776 GB, free: 13.4 MB / 0.5294 GB Notification: Performance of NFTyping.typeComponents: time 0.00146/0.2325, allocations: 341.8 kB / 0.6779 GB, free: 13.07 MB / 0.5294 GB Notification: Performance of NFTyping.typeBindings: time 0.001863/0.2344, allocations: 437.2 kB / 0.6784 GB, free: 12.64 MB / 0.5294 GB Notification: Performance of NFTyping.typeClassSections: time 0.001735/0.2362, allocations: 481.9 kB / 0.6788 GB, free: 12.17 MB / 0.5294 GB Notification: Performance of NFFlatten.flatten: time 0.002427/0.2386, allocations: 1.601 MB / 0.6804 GB, free: 10.56 MB / 0.5294 GB Notification: Performance of NFFlatten.resolveConnections: time 0.0004567/0.2391, allocations: 199.2 kB / 0.6806 GB, free: 10.35 MB / 0.5294 GB Notification: Performance of NFEvalConstants.evaluate: time 0.001286/0.2404, allocations: 0.5957 MB / 0.6811 GB, free: 9.754 MB / 0.5294 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:41-9:55:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 3.0.0/HeatTransfer/Conduction/BaseClasses/temperature_u.mo:9:3-10:46:writable] Error: Non-array modification '"kg.K2/J"' for array component 'unit', possibly due to missing 'each'. Notification: Performance of FrontEnd: time 0.0009114/0.2413, allocations: 445.9 kB / 0.6816 GB, free: 9.316 MB / 0.5294 GB