Environment - simulationEnvironment: startTime=0 stopTime=432000 tolerance=1e-06 numberOfIntervals=2500 stepSize=172.8 Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.Validation.ThermalZone.ZoneCapacitanceMultiplier -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.11.13 03:53 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD EnergyPlus Starting EnergyPlus, Version 9.6.0-316f894e91, YMD=2024.11.13 03:53 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2017 for SPAWN-RUNPERIOD LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((mulCap.duc.m_flow >= 0.0 and mulCap.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= mulCap.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((defCap.duc.m_flow >= 0.0 and defCap.duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= defCap.duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0193863s reading init.xml | | | | | | 0.00181895s reading info.xml | | | | | | 0.000442701s [ 0.0%] pre-initialization | | | | | | 15.7365s [ 95.0%] initialization | | | | | | 1.9948e-05s [ 0.0%] steps | | | | | | 0.0269717s [ 0.2%] solver (excl. callbacks) | | | | | | 0.00338143s [ 0.0%] creating output-file | | | | | | 0.609106s [ 3.7%] event-handling | | | | | | 0.00957475s [ 0.1%] overhead | | | | | | 0.182475s [ 1.1%] simulation | | | | | | 16.5685s [100.0%] total | | | | | events | | | | | | 719 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 11204 steps taken | | | | | | 13361 calls of functionODE | | | | | | 9368 evaluations of jacobian | | | | | | 32 error test failures | | | | | | 0 convergence test failures | | | | | | 0.107749s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 8.96sec EnergyPlus Completed Successfully. Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 1.19sec EnergyPlus Completed Successfully.