Environment - simulationEnvironment:
startTime=0
stopTime=3600
tolerance=1e-06
numberOfIntervals=2500
stepSize=1.44
Regular simulation: ./Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3 -abortSlowSimulation -alarm=400 -lv LOG_STATS
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Using pre-compiled FMU /home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 11.1.0-maint.11.x/Resources/src/ThermalZones/EnergyPlus_9_6_0/FMUs/Zones3.fmu
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable North_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable South_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning: Variable Core_ZN_mSenFac does not specify units in /var/lib/jenkins/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_11_Buildings.ThermalZones.EnergyPlus_9_6_0.BaseClasses.Validation.FMUZoneAdapterZones3/spawn-FMUZoneAdapterZones3/EnergyPlus.fmu. It will not be converted to SI units.
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.core.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.north.#10;"
LOG_STDOUT | info | 0.000 FMUZoneAdapterZones3.building: Warning from EnergyPlus: "*** Test warning written by Zones3.south.#10;"
LOG_SUCCESS | info | The initialization finished successfully without homotopy method.
LOG_STATS | info | ### STATISTICS ###
| | | | | timer
| | | | | | 0.00884472s reading init.xml
| | | | | | 0.00096011s reading info.xml
| | | | | | 0.000123392s [ 0.1%] pre-initialization
| | | | | | 0.0950504s [ 83.1%] initialization
| | | | | | 3.026e-06s [ 0.0%] steps
| | | | | | 0.00209324s [ 1.8%] solver (excl. callbacks)
| | | | | | 0s [ 0.0%] creating output-file
| | | | | | 0.00570415s [ 5.0%] event-handling
| | | | | | 0.00335104s [ 2.9%] overhead
| | | | | | 0.00801616s [ 7.0%] simulation
| | | | | | 0.114341s [100.0%] total
| | | | | events
| | | | | | 59 state events
| | | | | | 0 time events
| | | | | solver: dassl
| | | | | | 980 steps taken
| | | | | | 980 calls of functionODE
| | | | | | 920 evaluations of jacobian
| | | | | | 0 error test failures
| | | | | | 0 convergence test failures
| | | | | | 0.000693596s time of jacobian evaluation
LOG_SUCCESS | info | The simulation finished successfully.