Environment - simulationEnvironment: startTime=0 stopTime=200 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.08 Regular simulation: ./Buildings_10_Buildings.Fluid.Movers.Validation.PowerEuler -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_dp.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_dp: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in PowerEuler.pump_dp: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in PowerEuler.pump_m_flow: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in PowerEuler.pump_m_flow: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0222299s reading init.xml | | | | | | 0.00229413s reading info.xml | | | | | | 0.000942819s [ 4.8%] pre-initialization | | | | | | 0.000736982s [ 3.8%] initialization | | | | | | 3.347e-06s [ 0.0%] steps | | | | | | 0.000462925s [ 2.4%] solver (excl. callbacks) | | | | | | 0.0014826s [ 7.5%] creating output-file | | | | | | 0.000183348s [ 0.9%] event-handling | | | | | | 0.00569922s [ 29.0%] overhead | | | | | | 0.0101295s [ 51.6%] simulation | | | | | | 0.0196408s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 69 steps taken | | | | | | 86 calls of functionODE | | | | | | 54 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0.000114596s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.