Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.57248e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_10_Buildings.Experimental.DHC.Plants.Cooling.Subsystems.Examples.CoolingTowersParallel -abortSlowSimulation -alarm=400 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:417:3-427:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((not (pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pum.per.etaHydMet == Buildings.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in CoolingTowersParallel.pum: Mover has per.etaHydMet=.Power_VolumeFlowRate or per.etaHydMet=.EulerNumber. | | | | This requires per.pressure to be provided. | | | | Because it is not, the model overrides this setting by using per.etaHydMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-439:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((pum.per.haveWMot_nominal or not (pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pum.per.etaMotMet == Buildings.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in CoolingTowersParallel.pum: Mover has per.etaMotMet=.Efficiency_MotorPartLoadRatio or per.etaMotMet=.GenericCurve. | | | | This requires per.WMot_nominal or per.pressure to be provided. Because neither is provided, | | | | the model overrides this setting and by using per.etaMotMet=.NotProvided. | | | | Also consider using models under Movers.Preconfigured which autopopulate a pressure curve." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 15554863.698310 | | | | ((tow.cooTow[2].per.FRWat >= 0.0 and tow.cooTow[2].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.cooTow[2].per.FRWat <= 1.0, has value: -1.11181e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 10.1.1-maint.10.0.x/Fluid/HeatExchangers/CoolingTowers/BaseClasses/Merkel.mo:93:3-94:53:writable] | | | | The following assertion has been violated at time 15555110.400000 | | | | ((tow.cooTow[1].per.FRWat >= 0.0 and tow.cooTow[1].per.FRWat <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= tow.cooTow[1].per.FRWat <= 1.0, has value: -3.40307e-26" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0209033s reading init.xml | | | | | | 0.00212807s reading info.xml | | | | | | 0.000676299s [ 0.1%] pre-initialization | | | | | | 0.0294465s [ 4.0%] initialization | | | | | | 1.9577e-05s [ 0.0%] steps | | | | | | 0.0157241s [ 2.2%] solver (excl. callbacks) | | | | | | 0.00280481s [ 0.4%] creating output-file | | | | | | 0.222826s [ 30.6%] event-handling | | | | | | 0.0137515s [ 1.9%] overhead | | | | | | 0.443052s [ 60.8%] simulation | | | | | | 0.728301s [100.0%] total | | | | | events | | | | | | 134 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 15500 steps taken | | | | | | 21614 calls of functionODE | | | | | | 3357 evaluations of jacobian | | | | | | 809 error test failures | | | | | | 0 convergence test failures | | | | | | 0.148769s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.