Environment - simulationEnvironment: startTime=1.0368e+07 stopTime=1.07136e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=138.24 Regular simulation: ./BuildingSystems_BuildingSystems.Technologies.SolarThermal.Examples.BigCollectorInstallationWithStorage -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_STDOUT | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/weather/Germany_Berlin.txt" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump1.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump1: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:389:3-396:39:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((pump2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning in BigCollectorInstallationWithStorage.pump2: Mover is flow or pressure controlled and uses default pressure curve. | | | | This leads to an approximate power consumption. | | | | Set nominalValuesDefineDefaultPressureCurve=true to suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Sensors/BaseClasses/PartialAbsoluteSensor.mo:28:3-33:32:writable] | | | | The following assertion has been violated during initialization at time 10368000.000000 | | | | ((not senTem1.warnAboutOnePortConnection)) --> "Sensor BigCollectorInstallationWithStorage.senTem1 can lead to numerical problems if connected to a scalar fluid port. | | | | Only connect it to a vectorized fluid port, such as used in 'BuildingSystems.Fluid.MixingVolumes`. | | | | See BuildingSystems.Fluid.Sensors.UsersGuide for more information. | | | | To disable this warning, set 'warnAboutOnePortConnection = false' in BigCollectorInstallationWithStorage.senTem1." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 10368276.480000 | | | | ((HX.m1_flow >= 0.0 and HX.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= HX.m1_flow <= 1e5, has value: -6.77439e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Climate/WeatherData/WeatherDataReader.mo:57:3-63:84:writable] | | | | The following assertion has been violated at time 10492277.760000 | | | | ((weatherData.cloudCover >= 0.0 and weatherData.cloudCover <= 8.0)) --> "Variable violating min/max constraint: 0.0 <= weatherData.cloudCover <= 8.0, has value: 8.01774" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildingSystems 2.0.0-master/Media/Antifreeze/PropyleneGlycolWater.mo:75:3-78:56:writable] | | | | The following assertion has been violated at time 10498083.840000 | | | | ((collectorInParallel.thermalCollectorInSerie[1].thermalCollector[3].vol[10].dynBal.medium.T <= 373.15)) --> " | | | | In BigCollectorInstallationWithStorage.collectorInParallel.thermalCollectorInSerie[1].thermalCollector[3].vol[10].dynBal.medium: Temperature T exceeded its maximum allowed value of 100 degC (373.15 Kelvin) | | | | as required from medium model "PropyleneGlycolWater(X_a = 0.4, property_T = 293.15)"." LOG_ASSERT | error | No event found, but assert was triggered. Throwing now!