Environment - simulationEnvironment: startTime=0 stopTime=100 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.04 Regular simulation: ./BuildingSystems_BuildingSystems.Fluid.FixedResistances.Examples.FlowJunction -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00552041s reading init.xml | | | | | | 0.00042101s reading info.xml | | | | | | 8.6513e-05s [ 1.0%] pre-initialization | | | | | | 0.000105568s [ 1.2%] initialization | | | | | | 1.082e-06s [ 0.0%] steps | | | | | | 0.00103634s [ 11.4%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.000265228s [ 2.9%] event-handling | | | | | | 0.00180878s [ 19.9%] overhead | | | | | | 0.00577218s [ 63.6%] simulation | | | | | | 0.00907569s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 292 steps taken | | | | | | 448 calls of functionODE | | | | | | 111 evaluations of jacobian | | | | | | 19 error test failures | | | | | | 1 convergence test failures | | | | | | 0.000143808s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.