Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo", uses=false) Using package BuildSysPro with version 3.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.008354/0.008354, allocations: 104.1 kB / 15.74 MB, free: 6.047 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001438/0.001438, allocations: 193.5 kB / 16.67 MB, free: 5.969 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.379/1.379, allocations: 222.9 MB / 240.4 MB, free: 15.14 MB / 206.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo): time 0.8685/0.8685, allocations: 143 MB / 433.6 MB, free: 11.99 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.00123/0.00123, allocations: 59.95 kB / 0.5954 GB, free: 12.35 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.2064/0.2076, allocations: 82.03 MB / 0.6755 GB, free: 10.42 MB / 0.5137 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.004406/0.2121, allocations: 2.315 MB / 0.6778 GB, free: 8.094 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.001158/0.2133, allocations: 0.4944 MB / 0.6783 GB, free: 7.598 MB / 0.5137 GB