Environment - simulationEnvironment: startTime=0 stopTime=1 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.0004 Regular simulation: ./BuildSysPro_BuildSysPro.IBPSA.Fluid.Movers.Examples.MoverParameter -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0-master/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:387:3-396:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0-master/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((not (pump_m_flow.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.Power_VolumeFlowRate or pump_m_flow.per.etaHydMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.HydraulicEfficiencyMethod.EulerNumber))) --> "*** Warning in MoverParameter.pump_m_flow: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0-master/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((pump_m_flow.per.haveWMot_nominal or not (pump_m_flow.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.Efficiency_MotorPartLoadRatio or pump_m_flow.per.etaMotMet == BuildSysPro.IBPSA.Fluid.Movers.BaseClasses.Types.MotorEfficiencyMethod.GenericCurve))) --> "*** Warning in MoverParameter.pump_m_flow: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0280007s reading init.xml | | | | | | 0.00288353s reading info.xml | | | | | | 9.1672e-05s [ 0.4%] pre-initialization | | | | | | 0.000814908s [ 3.5%] initialization | | | | | | 5.52e-06s [ 0.0%] steps | | | | | | 4.684e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | -1.38966e-21s [ -0.0%] event-handling | | | | | | 0.00547844s [ 23.8%] overhead | | | | | | 0.0165803s [ 72.1%] simulation | | | | | | 0.022994s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 2500 steps taken | | | | | | 2500 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.