Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001969/0.001969, allocations: 109 kB / 17.54 MB, free: 4.746 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.002057/0.002057, allocations: 185.9 kB / 20.71 MB, free: 1.586 MB / 14.72 MB " [Timeout remaining time 180] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.735/1.735, allocations: 207.6 MB / 231.3 MB, free: 3.215 MB / 174.1 MB " [Timeout remaining time 178] loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo", uses=false) [Timeout 180] "Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo): time 0.478/0.478, allocations: 55.7 MB / 339.1 MB, free: 11.95 MB / 270.1 MB " [Timeout remaining time 179] Using package Annex60 with version 1.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust") translateModel(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust,tolerance=1e-06,outputFormat="empty",numberOfIntervals=2500,variableFilter="",fileNamePrefix="Annex60_1.0.0_Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust") [Timeout 660] "Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Annex60 requested package Modelica of version 3.2.2. Modelica 3.2.3 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.002347/0.002347, allocations: 65.38 kB / 479.9 MB, free: 36.61 MB / 382.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1668/0.1691, allocations: 62.85 MB / 0.53 GB, free: 11.68 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Blocks/Math.mo:543:5-544:48:writable] Warning: Parameter mov.gaiSpe.k has no value, and is fixed during initialization (fixed=true), using available start value (start=1) as default value. Notification: Performance of NFInst.instantiate(Annex60.Fluid.FMI.Adaptors.Examples.ThermalZoneHVACNoExhaust): time 0.8635/1.033, allocations: 345.5 MB / 0.8674 GB, free: 1.598 MB / 0.6388 GB Notification: Performance of NFInst.instExpressions: time 0.6124/1.645, allocations: 39.14 MB / 0.9056 GB, free: 16.29 MB / 0.6544 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.009918/1.655, allocations: 138.3 kB / 0.9058 GB, free: 16.29 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Conversion/AirToOutlet.mo:92:3-94:60:writable] Warning: Connector bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Conversion/InletToAir.mo:76:3-78:60:writable] Warning: Connector bacPro_internal is not balanced: The number of potential variables (2) is not equal to the number of flow variables (0). Notification: Performance of NFTyping.typeComponents: time 0.00928/1.664, allocations: 2.544 MB / 0.9083 GB, free: 16.29 MB / 0.6544 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Adaptors/HVAC.mo:48:16-48:66:writable] Notification: From here: [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Annex60 1.0.0/Fluid/FMI/Adaptors/HVAC.mo:47:3-56:28:writable] Error: Type mismatch in binding 'quantity = fill(hvacAda.Medium.extraPropertiesNames, 2)', expected array dimensions [], got [2, 0]. Notification: Performance of FrontEnd: time 0.0002032/1.665, allocations: 44.89 kB / 0.9083 GB, free: 16.29 MB / 0.6544 GB " [Timeout remaining time 658] [Calling sys.exit(0), Time elapsed: 4.995324989780784]