Environment - simulationEnvironment: startTime=0 stopTime=3600 tolerance=1e-06 numberOfIntervals=2500 stepSize=1.44 Regular simulation: ./Annex60_1.0.0_Annex60.Fluid.Chillers.Validation.Carnot_TEva_reverseFlow -abortSlowSimulation -alarm=480 -lv LOG_STATS LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00480354s reading init.xml | | | | | | 0.000403587s reading info.xml | | | | | | 5.0154e-05s [ 0.4%] pre-initialization | | | | | | 0.000163557s [ 1.2%] initialization | | | | | | 1.753e-06s [ 0.0%] steps | | | | | | 5.462e-06s [ 0.0%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 1.3973e-05s [ 0.1%] event-handling | | | | | | 0.00275604s [ 20.1%] overhead | | | | | | 0.0107113s [ 78.2%] simulation | | | | | | 0.0137022s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: euler | | | | | | 10088 steps taken | | | | | | 10088 calls of functionODE | | | | | | 0 evaluations of jacobian | | | | | | 0 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.