/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=ModelicaTest_3.2.3_ModelicaTest.MultiBody.InitializationConversion.Joints_res.mat --tempDir=temp_ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints_fmu --startTime=0 --stopTime=0.2 --timeout=50 --tolerance=1e-06 ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.fmu LOG_STDOUT | info | Using sparse solver for linear system 0, | | | | because density of 0.016 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | Using sparse solver for linear system 8, | | | | because density of 0.017 remains under threshold of 0.200. LOG_STDOUT | info | The simulation runtime does not have access to sparse solvers. Defaulting to a dense linear system solver instead. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. info: maximum step size for 'model.root': 0.000400 info: Result file: ModelicaTest_3.2.3_ModelicaTest.MultiBody.InitializationConversion.Joints_res.mat (bufferSize=1) info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox1.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox2.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox3.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox4.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox5.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox6.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox7.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.bodyBox8.frameTranslation.shapeType will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.world.label1 will not be stored in the result file, because the signal type is not supported info: Parameter model.root.ModelicaTest_3_2_3_ModelicaTest_MultiBody_InitializationConversion_Joints.world.label2 will not be stored in the result file, because the signal type is not supported info: Final Statistics for 'model.root': NumSteps = 502 NumRhsEvals = 505 NumLinSolvSetups = 27 NumNonlinSolvIters = 504 NumNonlinSolvConvFails = 0 NumErrTestFails = 0