Environment - simulationEnvironment: startTime=0 stopTime=500 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.2 Regular simulation: ./ClaRa_dev_ClaRa.Components.TurboMachines.Pumps.Check.TestPump_L1_OffDesign -abortSlowSimulation -alarm=50 -emit_protected -lv LOG_STATS LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.2-main/Components/TurboMachines/Pumps/Fundamentals/Pump_Base.mo:30:3-30:93:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pump.Delta_p >= 0.0)) --> "Variable violating min constraint: 0.0 <= pump.Delta_p, has value: -500000" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00830635s reading init.xml | | | | | | 0.000705253s reading info.xml | | | | | | 0.0061507s [ 6.3%] pre-initialization | | | | | | 0.0362128s [ 36.8%] initialization | | | | | | 8.907e-06s [ 0.0%] steps | | | | | | 0.00257719s [ 2.6%] solver (excl. callbacks) | | | | | | 0.00526841s [ 5.4%] creating output-file | | | | | | 0.0112765s [ 11.5%] event-handling | | | | | | 0.00397565s [ 4.0%] overhead | | | | | | 0.0328519s [ 33.4%] simulation | | | | | | 0.0983221s [100.0%] total | | | | | events | | | | | | 29 state events | | | | | | 0 time events | | | | | solver: dassl | | | | | | 2219 steps taken | | | | | | 4240 calls of functionODE | | | | | | 1666 evaluations of jacobian | | | | | | 69 error test failures | | | | | | 344 convergence test failures | | | | | | 0.00391417s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.