OMSimulator --tempDir=temp_Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop_fmu --startTime=0 --stopTime=604800 --timeout=50 --tolerance=1e-06 Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.fmu stdout | info | ... loading "tab1" from "/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.0.1-maint.8.0.x/Resources/Data/Experimental/DHC/Loads/Examples/SwissResidential_20190916.mos" info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiCoo.filNam will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiCoo.loa.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiCoo.loa.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiCoo.terUniCoo.con.assMesYMinMax.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiHea.filNam will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiHea.loa.fileName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiHea.loa.tableName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop.buiHea.terUniHea.con.assMesYMinMax.message will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors error: [fmi2logger] Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop (logStatusError): fmi2SetContinuousStates: Illegal call sequence. fmi2SetContinuousStates is not allowed in Terminated state. error: [setContinuousStates] fmi2_import_set_continuous_states failed for FMU "model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop" error: [fmi2logger] Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop (logStatusError): fmi2SetContinuousStates: Illegal call sequence. fmi2SetContinuousStates is not allowed in Error state. error: [setContinuousStates] fmi2_import_set_continuous_states failed for FMU "model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop" error: [fmi2logger] Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop (logStatusError): fmi2SetContinuousStates: Illegal call sequence. fmi2SetContinuousStates is not allowed in Error state. error: [setContinuousStates] fmi2_import_set_continuous_states failed for FMU "model.root.Buildings_maint_8_0_x_Buildings_Experimental_DHC_Loads_Examples_CouplingTimeSeriesSingleLoop"