OMSimulator --tempDir=temp_Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource_fmu --startTime=0 --stopTime=600 --timeout=50 --tolerance=1e-06 Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.fmu info: maximum step size for 'model.root': 0.001000 info: Result file: model_res.mat (bufferSize=10) info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.C.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.C1.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.C2.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.C3.substanceName will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.assEqu.message will not be stored in the result file, because the signal type is not supported info: Parameter model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.assEqu1.message will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.sou.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.sou1.substanceName will not be stored in the result file, because the signal type is not supported info: Variable model.root.Buildings_maint_7_0_x_Buildings_Fluid_Sources_Examples_TraceSubstancesFlowSource.sou2.substanceName will not be stored in the result file, because the signal type is not supported error: [operator()] Timeout occurred during simulation info: 0 warnings info: 1 errors info: Final Statistics for 'model.root': NumSteps = 545734 NumRhsEvals = 546028 NumLinSolvSetups = 27303 NumNonlinSolvIters = 546027 NumNonlinSolvConvFails = 2 NumErrTestFails = 0 [CVODE ERROR] CVode cvode_mem = NULL illegal. error: [doStep] SUNDIALS_ERROR: CVode() failed with flag = -21