/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning_res.mat --tempDir=temp_Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIDControlAutoTuning_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=800 --tolerance=1e-06 Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIDControlAutoTuning.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning/model-ec2uocfh" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_latest_Buildings_Fluid_HeatExchangers_Examples_WetCoilCounterFlowPIDControlAutoTuning.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOnRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOnRec.yRec.y, has value: 0" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings master/Controls/OBC/CDL/Discrete/TriggeredSampler.mo:12:3-14:72:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((con.resPro.onOffPer.timOffRec.yRec.y >= 1e-13)) --> "Variable violating min constraint: 1e-13 <= con.resPro.onOffPer.timOffRec.yRec.y, has value: 0" info: maximum step size for 'model.root': 1.440000 info: Result file: Buildings_latest_Buildings.Fluid.HeatExchangers.Examples.WetCoilCounterFlowPIDControlAutoTuning_res.mat (bufferSize=1) info: Final Statistics for 'model.root': NumSteps = 690 NumRhsEvals = 844 NumLinSolvSetups = 98 NumNonlinSolvIters = 843 NumNonlinSolvConvFails = 1 NumErrTestFails = 28 info: 2 warnings info: 0 errors