/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat --tempDir=temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu --startTime=1.5552e+07 --stopTime=1.56384e+07 --timeout=50 --tolerance=1e-07 Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC.fmu LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((hvaCon2.fan.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.3-maint.9.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:348:3-357:39:writable] | | | | The following assertion has been violated during initialization at time 15552000.000000 | | | | ((hvaCon2.fan2.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 172.800000 info: Result file: Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC_res.mat (bufferSize=1) LOG_ASSERT | debug | The boundary mass fractions in medium "Air" in model "Boundary_pT" | | | | do not sum up to 1. Instead, sum(X_boundary) = 0.999997: | | | | X_boundary[1] = 0.010177 "water" | | | | X_boundary[2] = 0.98982 "air" error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_9_Buildings.Fluid.FMI.ExportContainers.Validation.RoomHVAC/temp_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC_fmu/model-pzwu2jyx/temp/0001_Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_9_Buildings_Fluid_FMI_ExportContainers_Validation_RoomHVAC" info: Final Statistics for 'model.root': NumSteps = 215 NumRhsEvals = 308 NumLinSolvSetups = 35 NumNonlinSolvIters = 307 NumNonlinSolvConvFails = 0 NumErrTestFails = 6 info: 0 warnings info: 2 errors