/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu --startTime=0 --stopTime=3.1536e+07 --timeout=50 --tolerance=1e-06 Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall.fmu LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu/model-khov0zsb/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu/model-khov0zsb/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgStand-aloneRetailNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu/model-khov0zsb/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/Plants/AlamedaOceanT.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((larOff.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((larOff.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((larOff.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ret.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ret.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((ret.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/Fluid/Interfaces.mo:13:5-14:68:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.sinHea.ports[1].m_flow >= 0.0 and pla.sinHea.ports[1].m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pla.sinHea.ports[1].m_flow <= 1e5, has value: -2.70604e-16" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.hea.m2_flow >= 0.0 and pla.hea.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= pla.hea.m2_flow <= 1e5, has value: -2.70604e-16" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Chillers/BaseClasses/Carnot.mo:121:3-123:56:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((pla.hea.yPL >= 0.0)) --> "Variable violating min constraint: 0.0 <= pla.hea.yPL, has value: -1.53281e-18" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:25:3-26:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((larOff.chi.m1_flow >= 0.0 and larOff.chi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= larOff.chi.m1_flow <= 1e5, has value: -1.81084e-53" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ret.heaPum.m2_flow >= 0.0 and ret.heaPum.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ret.heaPum.m2_flow <= 1e5, has value: -1.02976e-45" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:30:3-31:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ret.heaPumHotWat.m2_flow >= 0.0 and ret.heaPumHotWat.m2_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ret.heaPumHotWat.m2_flow <= 1e5, has value: -4.21948e-32" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/PartialFourPortInterface.mo:25:3-26:84:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((ret.chi.m1_flow >= 0.0 and ret.chi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= ret.chi.m1_flow <= 1e5, has value: -8.15138e-32" info: maximum step size for 'model.root': 63072.000000 info: Result file: model_res.mat (bufferSize=10) info: Parameter model.root.Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall.watTem.tableName will not be stored in the result file, because the signal type is not supported LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 17092512.000000 | | | | ((noEvent(abs(ret.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret.heaPum.eva.vol.steBal.m_flow_small, abs(ret.heaPum.m2_flow))))) --> "In HeatingCoolingHotWaterSmall.ret.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.14041 W and the mass flow rate equals -1.75008e-07 kg/s, | | | | which results in a temperature difference 404.953 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu/model-khov0zsb/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable weaDat.computeWetBulbTemperature LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 17092512.000000 | | | | ((noEvent(abs(ret.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret.heaPum.eva.vol.steBal.m_flow_small, abs(ret.heaPum.m2_flow))))) --> "In HeatingCoolingHotWaterSmall.ret.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.14041 W and the mass flow rate equals -1.7501e-07 kg/s, | | | | which results in a temperature difference 404.953 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu/model-khov0zsb/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 17092512.000000 | | | | ((noEvent(abs(ret.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * ret.heaPum.eva.vol.steBal.m_flow_small, abs(ret.heaPum.m2_flow))))) --> "In HeatingCoolingHotWaterSmall.ret.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 1.14041 W and the mass flow rate equals -1.7501e-07 kg/s, | | | | which results in a temperature difference 404.953 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.Validation.HeatingCoolingHotWaterSmall/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall_fmu/model-khov0zsb/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_Validation_HeatingCoolingHotWaterSmall (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable weaDat.computeWetBulbTemperature info: Final Statistics for 'model.root': NumSteps = 27555 NumRhsEvals = 39061 NumLinSolvSetups = 7446 NumNonlinSolvIters = 38987 NumNonlinSolvConvFails = 48 NumErrTestFails = 2339 info: 0 warnings info: 6 errors