/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT_fmu --startTime=0 --stopTime=864000 --timeout=50 --tolerance=1e-08 Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT.fmu LOG_STDOUT | info | ... loading "tab1" from "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT_fmu/model-wkq7rscd/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT/resources/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Resources/Data/Obsolete/DistrictHeatingCooling/SubStations/VaporCompression/RefBldgLargeOfficeNew2004_7.1_5.0_3C_USA_CA_SAN_FRANCISCO.mos" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumHea.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumHotWat.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:352:3-361:39:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((subSta.pumChi.nominalValuesDefineDefaultPressureCurve)) --> "*** Warning: You are using a flow or pressure controlled mover with the | | | | default pressure curve. | | | | This leads to approximate calculations of the electrical power | | | | consumption. Add the correct pressure curve in the record per | | | | to obtain an accurate computation. | | | | Setting nominalValuesDefineDefaultPressureCurve=true will suppress this warning." info: maximum step size for 'model.root': 1728.000000 info: Result file: model_res.mat (bufferSize=10) LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 684288.000000 | | | | ((noEvent(abs(subSta.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * subSta.heaPum.eva.vol.steBal.m_flow_small, abs(subSta.heaPum.m2_flow))))) --> "In HeatingCoolingHotwaterTimeSeries_dT.subSta.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.68649 W and the mass flow rate equals -1.10616e-06 kg/s, | | | | which results in a temperature difference 306.934 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT_fmu/model-wkq7rscd/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable weaDat.computeWetBulbTemperature LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 684288.000000 | | | | ((noEvent(abs(subSta.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * subSta.heaPum.eva.vol.steBal.m_flow_small, abs(subSta.heaPum.m2_flow))))) --> "In HeatingCoolingHotwaterTimeSeries_dT.subSta.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.68649 W and the mass flow rate equals -1.10617e-06 kg/s, | | | | which results in a temperature difference 306.934 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT_fmu/model-wkq7rscd/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT (logFmi2Call): fmi2CompletedIntegratorStep: terminated by an assertion. error: [doStep] fmi2_completedIntegratorStep failed for FMU "model.root.Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 8.1.4-maint.8.1.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:144:5-152:68:writable] | | | | The following assertion has been violated at time 684288.000000 | | | | ((noEvent(abs(subSta.heaPum.eva.Q_flow) < 836800.0 * max(0.001 * subSta.heaPum.eva.vol.steBal.m_flow_small, abs(subSta.heaPum.m2_flow))))) --> "In HeatingCoolingHotwaterTimeSeries_dT.subSta.heaPum.eva.vol.steBal: | | | | The heat flow rate equals 4.68649 W and the mass flow rate equals -1.10617e-06 kg/s, | | | | which results in a temperature difference 306.934 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_8_Buildings.Obsolete.DistrictHeatingCooling.SubStations.VaporCompression.Validation.HeatingCoolingHotwaterTimeSeries_dT/temp_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT_fmu/model-wkq7rscd/temp/0001_Buildings_8_Buildings_Obsolete_DistrictHeatingCooling_SubStations_VaporCompression_Validation_HeatingCoolingHotwaterTimeSeries_dT (logFmi2Call): fmi2GetBoolean: terminated by an assertion. error: [updateSignals] failed to fetch variable weaDat.computeWetBulbTemperature info: Final Statistics for 'model.root': NumSteps = 3484 NumRhsEvals = 5789 NumLinSolvSetups = 1822 NumNonlinSolvIters = 5762 NumNonlinSolvConvFails = 0 NumErrTestFails = 662 info: 0 warnings info: 6 errors