/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor_ZeroInput_res.mat --tempDir=temp_Buildings_12_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor_ZeroInput_fmu --startTime=0 --stopTime=100 --stepSize=0.04 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor_ZeroInput.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor_ZeroInput" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor_ZeroInput" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor_ZeroInput/model-332gsjhm" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.HeatPumps.Compressors.Validation.ReciprocatingCompressor_ZeroInput" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_12_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor_ZeroInput.fmu - startTime: 0.000000 - stopTime: 100.000000 - tolerance: 0.000001 - stepSize: 0.040000 info: model doesn't contain any continuous state LOG_ASSERT | debug | Division by zero 114.55 * T / p in function context LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | Division by zero 114.55 * T / p in function context LOG_ASSERT | debug | Division by zero 114.55 * T / p in function context LOG_ASSERT | debug | Division by zero 114.55 * T / p in function context LOG_ASSERT | debug | Solving non-linear system 30 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor_ZeroInput/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.Buildings_12_Buildings_Fluid_HeatPumps_Compressors_Validation_ReciprocatingCompressor_ZeroInput" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors