/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator -r=Buildings_12_Buildings.Fluid.Chillers.Examples.Carnot_TEva_res.mat --tempDir=temp_Buildings_12_Buildings_Fluid_Chillers_Examples_Carnot_TEva_fmu --startTime=0 --stopTime=3600 --stepSize=1.44 --timeout=400 --tolerance=1e-06 Buildings_12_Buildings_Fluid_Chillers_Examples_Carnot_TEva.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Chillers.Examples.Carnot_TEva" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Chillers.Examples.Carnot_TEva" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Chillers.Examples.Carnot_TEva/model-e3w7w30s" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Fluid.Chillers.Examples.Carnot_TEva" info: *** FMU Simulation Info *** - model: model (model exchange) - path: Buildings_12_Buildings_Fluid_Chillers_Examples_Carnot_TEva.fmu - startTime: 0.000000 - stopTime: 3600.000000 - tolerance: 0.000001 - stepSize: 1.440000 info: model doesn't contain any continuous state LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Interfaces/StaticTwoPortConservationEquation.mo:146:5-154:68:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((noEvent(abs(chi.con.Q_flow) < 836800.0 * max(0.001 * chi.con.vol.steBal.m_flow_small, abs(chi.m1_flow))))) --> "In Carnot_TEva.chi.con.vol.steBal: | | | | The heat flow rate equals 227860 W and the mass flow rate equals 0 kg/s, | | | | which results in a temperature difference 1.68778e+08 K > dTMax=200 K. | | | | This may indicate that energy is not conserved for small mass flow rates. | | | | The implementation may require prescribedHeatFlowRate = false." error: [fmi2logger] [fmi2Error] Buildings_12_Buildings_Fluid_Chillers_Examples_Carnot_TEva/logFmi2Call: fmi2ExitInitializationMode: terminated by an assertion. error: [initialize] fmi2_import_exit_initialization_mode failed for FMU "model.root.Buildings_12_Buildings_Fluid_Chillers_Examples_Carnot_TEva" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors