/home/hudson/saved_omc/OMSimulator/install/bin/OMSimulator --tempDir=temp_AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler_fmu --startTime=0 --stopTime=14400 --stepSize=5 --timeout=50 --tolerance=0.0001 AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler.fmu warning: Failed to load settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input warning: Failed to save settings: [json.exception.parse_error.101] parse error at line 4, column 1: syntax error while parsing value - unexpected '}'; expected end of input info: Set temp directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler" info: New model "model" with corresponding temp directory "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler/model-pueqyfzz" info: Set working directory to "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler" info: *** FMU Simulation Info *** - model: model (model exchange) - path: AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler.fmu - startTime: 0.000000 - stopTime: 14400.000000 - tolerance: 0.000100 - stepSize: 5.000000 LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler/764.fmutmp/sources/AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler_functions.c:222: Invalid root: (0)^(-1.5) LOG_STDOUT | warning | Non-Linear Solver try to handle a problem with a called assert. LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler/764.fmutmp/sources/AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler_functions.c:222: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler/764.fmutmp/sources/AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler_functions.c:222: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/AixLib_AixLib.Airflow.AirHandlingUnit.ModularAirHandlingUnit.Components.Validation.Cooler/764.fmutmp/sources/AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler_functions.c:222: Invalid root: (0)^(-1.5) LOG_ASSERT | debug | Solving non-linear system 174 failed at time=0. | | | | For more information please use -lv LOG_NLS. error: [fmi2logger] [fmi2Error] AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler/logFmi2Call: internalEventUpdate: terminated by an assertion. error: [doEventIteration] fmi2_import_new_discrete_states failed for FMU "model.root.AixLib_AixLib_Airflow_AirHandlingUnit_ModularAirHandlingUnit_Components_Validation_Cooler" error: [initialize] Initialization of system "model.root" failed error: [SimulateSingleFMU] oms_initialize failed info: 2 warnings info: 4 errors