PowerGrids test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
71 51 51 51 51 51 45 36

Test started: 2026-04-25 08:41:59
Total time taken: 0:11:28
System info: AMD Ryzen 9 9950X3D 16-Core Processor, 124 GB RAM, Ubuntu 24.04.4 LTS

OpenModelica Version: OMCompiler v1.27.0-dev.370+g91a32377fa

FMI tool: b'FMPy version 0.3.29'

FMI version: 2.0

OpenModelicaLibraryTesting Changes
CommitDateAuthorSummary
1dd4db72026-04-19 14:25:16 +0200Adrian Popforce fetch of tags to handle the floating tag 'nightly' (#285)

Tested Library: PowerGrids 1.0.3 FMPy version 0.3.29

{
 "path": "PowerGrids",
 "provides": [
  "1.0.0",
  "1.0.1",
  "1.0.2"
 ],
 "support": "fullSupport",
 "uses": {
  "Modelica": "3.2.3"
 },
 "version": "1.0.3",
 "zipfile": "https://github.com/PowerGrids/PowerGrids/archive/1858e8b1d5234a3d9506e89da89c3c1df793b866.zip"
}

BuildModel time limit: 660s
Simulation time limit: 50s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Reference Files: https://github.com/PowerGrids/PowerGrids-ref (8ae6d1da560c6162e2a3818e0ddc3e0622a6eb1c)

CommitDateAuthorSummary
8ae6d1d2024-01-29 11:21:23 +0100Francesco CasellaAdded reference files for 1.0.3

Verified using: OpenModelica 1.26.3~1-g7583224 (diffSimulationResults)

Flags:
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config:
{
 "library": "PowerGrids",
 "referenceFileExtension": "mat",
 "referenceFileNameDelimiter": ".",
 "referenceFiles": {
  "destination": "ReferenceFiles/PowerGrids",
  "giturl": "https://github.com/PowerGrids/PowerGrids-ref"
 },
 "referenceFinalDot": "_res."
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
PowerGrids.Controls.Test.TestDeadBand (sim)0.01 (8 verified)0.096.931.250.100.010.180.026.628.80
PowerGrids.Controls.Test.TestDerivativeLag (sim)0.01 (1/35 failed)0.126.781.210.090.010.000.026.678.67
PowerGrids.Controls.Test.TestDiscontinuousDeadBand (sim)0.00 (8 verified)0.126.971.300.090.010.170.016.698.94
PowerGrids.Controls.Test.TestFirstOrderWithNonWindupLimiter (sim)0.01 (78 verified)0.118.061.200.090.190.010.037.749.91
PowerGrids.Controls.Test.TestIntegratorWithNonWindupLimiter (sim)0.01 (62 verified)0.097.281.240.100.010.160.026.999.14
PowerGrids.Controls.Test.TestLeadLag (sim)0.01 (1/38 failed)0.107.101.180.080.010.000.016.998.93
PowerGrids.Controls.Test.TestLeadLagWithNonWindupLimiter (sim)0.01 (2/82 failed)0.118.391.260.090.190.010.038.0810.31
PowerGrids.Controls.Test.TestLeadMOrderLag (sim)0.07 (1/1346 failed)0.1510.361.230.270.220.060.109.7212.39
PowerGrids.Controls.Test.TestLimiterWithLag (sim)0.01 (1/33 failed)0.097.201.310.090.010.160.026.929.14
PowerGrids.Controls.Test.TestPIWithNonWindupLimiter (sim)0.01 (2/99 failed)0.107.101.280.100.190.010.036.789.03
PowerGrids.Controls.Test.TestRampTrackingFilter (sim)0.05 (2020 verified)0.1412.931.240.280.420.130.3511.7514.92
PowerGrids.Electrical.Test.LoadImpedancePQ (sim)0.02 (228 verified)0.098.171.140.260.040.010.047.819.91
PowerGrids.Electrical.Test.OneBusImpedanceOneLoad (sim)0.01 (82 verified)0.107.771.080.080.160.010.027.509.44
PowerGrids.Electrical.Test.OneBusImpedanceOneVariableLoad (sim)0.01 (160 verified)0.128.061.140.240.030.010.037.749.82
PowerGrids.Electrical.Test.OneBusImpedanceVariableVoltageOneLoad (sim)0.01 (89 verified)0.107.831.150.080.160.010.027.559.59
PowerGrids.Electrical.Test.OneBusOneLoad (sim)0.01 (82 verified)0.117.741.160.090.160.010.027.469.53
PowerGrids.Electrical.Test.OneBusTransmissionLineOneLoad (sim)0.01 (138 verified)0.108.001.160.250.030.010.037.679.78
PowerGrids.Electrical.Test.OneBusTransmissionLineShuntOneLoad (sim)0.01 (138 verified)0.118.001.090.250.040.010.037.679.71
PowerGrids.Electrical.Test.SynchronousMachine4Windings (sim)0.02 (148 verified)0.128.741.220.110.220.010.048.3510.66
PowerGrids.Electrical.Test.SynchronousMachine4WindingsAccurate (sim)0.01 (148 verified)0.118.881.240.100.210.020.058.5110.75
PowerGrids.Electrical.Test.SynchronousMachine4WindingsExact (sim)0.01 (148 verified)0.128.921.200.110.230.020.058.5010.80
PowerGrids.Electrical.Test.SynchronousMachine4WindingsNoLoad (sim)0.06 (148 verified)0.258.781.250.100.200.020.048.4310.85
PowerGrids.Electrical.Test.SynchronousMachine4WindingsNoLoadAccurate (sim)0.06 (148 verified)0.268.911.140.100.220.020.058.5210.88
PowerGrids.Electrical.Test.SynchronousMachine4WindingsNoLoadExact (sim)0.06 (148 verified)0.258.971.210.090.220.020.058.5811.02
PowerGrids.Electrical.Test.SynchronousMachine4WindingsPowerSwing 0.00-1.001.19-1.000.000.000.000.001.70
PowerGrids.Electrical.Test.TestExciterRectifierRegulationCharacteristicIEEE (sim)0.01 (1/3 failed)0.096.911.180.100.010.000.146.668.73
PowerGrids.Electrical.Test.TestExciterVoltageTransducerIEEE (sim)0.01 (57 verified)0.097.121.260.100.010.170.026.829.01
PowerGrids.Electrical.Test.TestOneBusTransmissionLineWithBreakersOneLoad (sim)0.01 (148 verified)0.118.391.270.270.040.010.038.0310.27
PowerGrids.Electrical.Test.TestTapChangerLogicInterval (sim)0.01 (16 verified)0.107.151.230.080.010.150.026.888.99
PowerGrids.Electrical.Test.TestTapChangerLogicMax (sim)0.01 (1/14 failed)0.137.031.180.080.010.000.166.778.86
PowerGrids.Electrical.Test.TestTerminalVoltageTransducerIEEE (sim)0.01 (47 verified)0.126.891.210.110.010.000.186.608.81
PowerGrids.Electrical.Test.TestTransformerFixedRatio (sim)0.01 (141 verified)0.108.401.260.270.040.010.038.0510.29
PowerGrids.Electrical.Test.TestTransformerFixedRatioWithBreaker (sim)0.01 (239 verified)0.139.071.280.290.060.020.048.6511.01
PowerGrids.Electrical.Test.TestTransformerWithTapChangerInterval (sim)0.01 (164 verified)0.138.371.270.260.040.010.038.0310.34
PowerGrids.Electrical.Test.TestTransformerWithTapChangerMax (sim)0.01 (163 verified)0.117.831.260.280.050.020.037.459.78
PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortA (sim)0.01 (250 verified)0.108.951.300.300.070.020.068.5010.89
PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB (sim)0.01 (250 verified)0.118.881.250.300.080.030.058.4210.76
PowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortsAB (sim)0.01 (250 verified)0.129.171.290.310.080.020.058.7111.11
PowerGrids.Electrical.Test.TestTwoBusesTwoTransmLinesWithBreakersOneLoad (sim)0.01 (250 verified)0.128.801.290.300.060.020.048.3710.75
PowerGrids.Electrical.Test.TwoBusesInductiveTransmissionLine (sim)0.01 (138 verified)0.097.391.190.250.030.010.037.079.17
PowerGrids.Electrical.Test.TwoBusesPowerTransferTransmissionLine (sim)0.01 (138 verified)0.097.641.240.240.030.010.037.329.53
PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLine (sim)0.01 (138 verified)0.107.481.200.250.030.010.037.169.26
PowerGrids.Electrical.Test.TwoBusesResistiveTransmissionLineFault (sim)0.01 (284 verified)0.108.361.170.270.060.020.057.9610.17
PowerGrids.Electrical.Test.TwoBusesShuntTransmissionLine (sim)0.01 (138 verified)0.097.491.150.240.030.010.037.199.23
PowerGrids.Examples.ENTSOE.SteadyState 0.00-1.001.15-1.000.000.000.000.001.68
PowerGrids.Examples.ENTSOE.TestCase1 0.00-1.001.14-1.000.000.000.000.001.67
PowerGrids.Examples.ENTSOE.TestCase2 0.00-1.001.26-1.000.000.000.000.001.81
PowerGrids.Examples.ENTSOE.TestCase3 0.00-1.001.26-1.000.000.000.000.001.82
PowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection (sim) 0.3040.061.211.071.470.260.8336.4342.12
PowerGrids.Examples.IEEE14bus.IEEE14busLine1to5Opening (sim) 0.2942.061.271.051.510.240.8638.4144.22
PowerGrids.Examples.IEEE14bus.IEEE14busLoad2Variation (sim) 0.2638.061.241.081.690.340.8534.1040.14
PowerGrids.Examples.IEEE14bus.IEEE14busPowerFlow 0.00-1.001.29-1.000.000.000.000.001.89
PowerGrids.Examples.IEEE14bus.IEEE14busStaticNetwork (sim) 0.2842.461.261.091.750.310.8538.4544.59
PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridParametersChange 0.00-1.001.24-1.000.000.000.000.001.81
PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithControlledGen 0.00-1.001.19-1.000.000.000.000.001.74
PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithPSS 0.00-1.001.20-1.000.000.000.000.001.76
PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithReferenceCalculation 0.00-1.001.23-1.000.000.000.000.001.78
PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithReferenceCalculationSat 0.00-1.001.23-1.000.000.000.000.001.76
PowerGrids.Examples.Tutorial.GridOperation.Controlled.ControlledGridWithoutPSS 0.00-1.001.24-1.000.000.000.000.001.79
PowerGrids.Examples.Tutorial.GridOperation.LoadChange.LoadChangeByInputSignals 0.00-1.001.15-1.000.000.000.000.001.72
PowerGrids.Examples.Tutorial.GridOperation.LoadChange.LoadChangeByModifier 0.00-1.001.24-1.000.000.000.000.001.82
PowerGrids.Examples.Tutorial.GridOperation.LoadChange.LoadChangeByModifierUsingExtends 0.00-1.001.21-1.000.000.000.000.001.79
PowerGrids.Examples.Tutorial.GridOperation.Static.PowerFlow 0.00-1.001.24-1.000.000.000.000.001.81
PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGrid 0.00-1.001.25-1.000.000.000.000.001.81
PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGridComputedParameters 0.00-1.001.14-1.000.000.000.000.001.69
PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGridDifferentGeneratorParam 0.00-1.001.23-1.000.000.000.000.001.80
PowerGrids.Examples.Tutorial.GridOperation.Static.StaticGridDifferentNominals 0.00-1.001.20-1.000.000.000.000.001.80
PowerGrids.Examples.Tutorial.IslandOperation.PowerFlow (sim) 0.109.801.150.340.100.030.079.2611.54
PowerGrids.Examples.Tutorial.IslandOperation.TwoGeneratorsFixedFrequencyReference (sim) 0.1313.651.210.350.430.070.3412.4515.51
PowerGrids.Examples.Tutorial.IslandOperation.TwoGeneratorsOneReferenceGenerator (sim) 0.1313.981.270.390.480.080.3412.6815.91
PowerGrids.Functions.Test.TestTimeConstants (sim)0.00 (3 verified)0.106.921.240.090.010.000.146.688.77