Environment - simulationEnvironment: startTime=0 stopTime=1000 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.4 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankOverfilling -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -inputPath=.. -r=../ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankOverfilling_ida_res.mat -s ida) LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/TankCuboid.mo:47:3-47:136:writable] | | | | The following assertion has been violated at time 17.190857 | | | | ((tank1.V_liquid <= tank1.V_ref)) --> "In "TankOverfilling.tank1": Trying to fit more liquid into tank than it holds" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00348316s reading init.xml | | | | | | 0.000348035s reading info.xml | | | | | | 0.00296388s [ 1.9%] pre-initialization | | | | | | 0.000394642s [ 0.3%] initialization | | | | | | 1.1752e-05s [ 0.0%] steps | | | | | | 0.00615653s [ 3.9%] solver (excl. callbacks) | | | | | | 0.000584323s [ 0.4%] creating output-file | | | | | | 2.661e-05s [ 0.0%] event-handling | | | | | | 0.00225251s [ 1.4%] overhead | | | | | | 0.144399s [ 92.1%] simulation | | | | | | 0.156789s [100.0%] total | | | | | events | | | | | | 4 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 5676 steps taken | | | | | | 8560 calls of functionODE | | | | | | 386 evaluations of jacobian | | | | | | 265 error test failures | | | | | | 66 convergence test failures | | | | | | 0.0158018s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.