Environment - simulationEnvironment: startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.008 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -inputPath=.. -r=../ThermofluidStream_dev_ThermofluidStream.Boundaries.Tests.TankFillingClosedTank_ida_res.mat -s ida) LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((flowResistance.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Negative massflow at tank inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((staticHead1.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Negative massflow at tank inlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:154:5-154:138:writable] | | | | The following assertion has been violated at time 0.008000 | | | | ((staticHead1.inlet.m_flow > tank1.m_flow_assert)) --> "In "TankFillingClosedTank.tank1": Positive massflow at tank outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:154:5-154:138:writable] | | | | The following assertion has been violated at time 2.392000 | | | | ((staticHead.inlet.m_flow > tank.m_flow_assert)) --> "In "TankFillingClosedTank.tank": Positive massflow at tank outlet" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ThermofluidStream main/Boundaries/Internal/PartialTank.mo:151:5-151:135:writable] | | | | The following assertion has been violated at time 2.392000 | | | | ((staticHead.inlet.m_flow > tank1.m_flow_assert)) --> "In "TankFillingClosedTank.tank1": Negative massflow at tank inlet" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.00444901s reading init.xml | | | | | | 0.000465445s reading info.xml | | | | | | 0.0047324s [ 5.2%] pre-initialization | | | | | | 0.000466397s [ 0.5%] initialization | | | | | | 2.5308e-05s [ 0.0%] steps | | | | | | 0.00209642s [ 2.3%] solver (excl. callbacks) | | | | | | 0.00077049s [ 0.8%] creating output-file | | | | | | 1.4542e-05s [ 0.0%] event-handling | | | | | | 0.0023808s [ 2.6%] overhead | | | | | | 0.0806228s [ 88.5%] simulation | | | | | | 0.0911091s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 1044 steps taken | | | | | | 1473 calls of functionODE | | | | | | 96 evaluations of jacobian | | | | | | 61 error test failures | | | | | | 0 convergence test failures | | | | | | 0.00820915s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.