Environment - simulationEnvironment: startTime=0 stopTime=50000 tolerance=1e-06 numberOfIntervals=10000 stepSize=5 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../ClaRa_ClaRa.Basics.ControlVolumes.FluidVolumes.Check.Validation_VolumeVLE_L2_HeatTransfer_2ph_shell -abortSlowSimulation -alarm=240 -emit_protected -lv LOG_STATS -inputPath=.. -r=../ClaRa_ClaRa.Basics.ControlVolumes.FluidVolumes.Check.Validation_VolumeVLE_L2_HeatTransfer_2ph_shell_ida_res.mat -s ida) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/Fundamentals/HeatTransport/VLE_HT/HeatTransfer_L2.mo:19:3-19:97:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Volume.heattransfer.Delta_T_wi >= 0.0)) --> "Variable violating min constraint: 0.0 <= Volume.heattransfer.Delta_T_wi, has value: -3.807" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/Fundamentals/HeatTransport/VLE_HT/HeatTransfer_L2.mo:20:3-20:98:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Volume.heattransfer.Delta_T_wo >= 0.0)) --> "Variable violating min constraint: 0.0 <= Volume.heattransfer.Delta_T_wo, has value: -1.00991" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/Fundamentals/HeatTransport/VLE_HT/HeatTransfer_L2.mo:21:3-21:98:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Volume.heattransfer.Delta_T_mean >= 0.0)) --> "Variable violating min constraint: 0.0 <= Volume.heattransfer.Delta_T_mean, has value: -2.10786" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/Fundamentals/HeatTransport/VLE_HT/HeatTransfer_L2.mo:23:3-23:61:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Volume.heattransfer.Delta_T_U >= 0.0)) --> "Variable violating min constraint: 0.0 <= Volume.heattransfer.Delta_T_U, has value: -3.807" LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.9.0/Basics/ControlVolumes/Fundamentals/HeatTransport/VLE_HT/HeatTransfer_L2.mo:24:3-24:61:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((Volume.heattransfer.Delta_T_L >= 0.0)) --> "Variable violating min constraint: 0.0 <= Volume.heattransfer.Delta_T_L, has value: -1.00991" LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 2.0569e-05s [ 0.0%] pre-initialization | | | | | | 0.0219247s [ 18.7%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 0.00165999s [ 1.4%] solver (excl. callbacks) | | | | | | 0.00232131s [ 2.0%] creating output-file | | | | | | 0s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 0.0912869s [ 77.9%] simulation | | | | | | 0.117214s [100.0%] total | | | | | events | | | | | | 0 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 542 steps taken | | | | | | 1131 calls of functionODE | | | | | | 290 evaluations of jacobian | | | | | | 80 error test failures | | | | | | 84 convergence test failures | | | | | | 0.0021925s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.