Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-08 numberOfIntervals=2500 stepSize=69.12 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../BuildSysPro_BuildSysPro.IBPSA.Fluid.HeatPumps.Examples.ScrollWaterToWater_OneRoomRadiator -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPum: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPum: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPumSou: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in ScrollWaterToWater_OneRoomRadiator.pumHeaPumSou: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/HeatPumps/BaseClasses/PartialWaterToWater.mo:84:3-89:58:writable] | | | | The following assertion has been violated at time 26905.567009 | | | | ((heaPum.P >= 0.0)) --> "Variable violating min constraint: 0.0 <= heaPum.P, has value: -3.00927e-36" LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0225872s reading init.xml | | | | | | 0.00184606s reading info.xml | | | | | | 0.000168246s [ 0.0%] pre-initialization | | | | | | 0.0205415s [ 0.9%] initialization | | | | | | 0.000181521s [ 0.0%] steps | | | | | | 0.0350597s [ 1.6%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0134955s [ 0.6%] event-handling | | | | | | 0.00739326s [ 0.3%] overhead | | | | | | 2.10438s [ 96.5%] simulation | | | | | | 2.18122s [100.0%] total | | | | | events | | | | | | 150 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 27430 steps taken | | | | | | 31276 calls of functionODE | | | | | | 3521 evaluations of jacobian | | | | | | 294 error test failures | | | | | | 0 convergence test failures | | | | | | 0.286764s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.