Environment - simulationEnvironment: startTime=0 stopTime=3.1536e+07 tolerance=1e-06 numberOfIntervals=2500 stepSize=12614.4 Regular simulation (ida: SUNDIALS IDA): (cd run_ida && ../BuildSysPro_BuildSysPro.IBPSA.Fluid.Examples.SimpleHouse -abortSlowSimulation -alarm=240 -lv LOG_STATS -inputPath=.. -s ida) LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in SimpleHouse.pump: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in SimpleHouse.pump: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:420:3-427:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in SimpleHouse.fan: per.etaHydMet is set to .Power_VolumeFlowRate or .EulerNumber. | | | | This requires that per.pressure be provided. | | | | Because it is not, | | | | the model will override this setting and use .NotProvided instead." LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.7.0/IBPSA/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:429:3-438:34:writable] | | | | The following assertion has been violated during initialization at time 0.000000 | | | | ((false)) --> "*** Warning in SimpleHouse.fan: per.etaMotMet is set to .Efficiency_MotorPartLoadRatio | | | | or .GenericCurve. This requires that per.WMot_nominal be provided | | | | or at least per.pressure be provided so that per.WMot_nominal can | | | | be estimated. Because neither is provided, | | | | the model will override this setting and use .NotProvided instead." LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.0234409s reading init.xml | | | | | | 0.00177456s reading info.xml | | | | | | 0.000163007s [ 0.0%] pre-initialization | | | | | | 0.0193746s [ 1.3%] initialization | | | | | | 0.000427213s [ 0.0%] steps | | | | | | 0.184154s [ 12.3%] solver (excl. callbacks) | | | | | | 0s [ 0.0%] creating output-file | | | | | | 0.0075092s [ 0.5%] event-handling | | | | | | 0.00373913s [ 0.2%] overhead | | | | | | 1.28341s [ 85.6%] simulation | | | | | | 1.49877s [100.0%] total | | | | | events | | | | | | 1012 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 159364 steps taken | | | | | | 200934 calls of functionODE | | | | | | 19911 evaluations of jacobian | | | | | | 4781 error test failures | | | | | | 120 convergence test failures | | | | | | 0.426402s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.