OpenModelica newInst-daemode from 2023-03-12 19:24:52 to 2023-03-15 00:50:34

Summary

OMC Commits9
Libraries Changed2
Number of Improvements19
Number of Regressions3
Number of Performance Improvements2
Number of Performance Regressions2

OpenModelica Changes

CommitAuthorSummary
3b8425a505Per ÖstlundFix variability check during lookup (#10401)
9d76c7b765bernhardbachmannImprove event handling by using dense output instead of hermite (#10404)
80e3f4b034arun3688fix matlab code for linearization (#10403)
a9f1ae085cAdeel AsgharAdd version information to getClassInformation (#10398)
1c6ddad21dAndreasCopy external libraries into Docker volume for FMU compilation (#10396)
74ee116f62bernhardbachmannKINSOL needs to have higher accuracy for some MSL models (#10399)
7a930eb42fPer ÖstlundIgnore missing modified elements in getModelInstance (#10393)
4a28b1968bPer ÖstlundCheck variability of components found in enclosing scopes (#10383)
c9a7342d60bernhardbachmannUtilize simulation flag -noRootFinding in GBODE (#10391)

Library Changes

LibraryChange
AESFrom version main (e642d030f8560e7699f3da7ac256b38cfeb9334c) to main (b56a56bd4598221f7e0fc3750e8445a0b3674ec0)
PowerGridsConfiguration hash (OMC settings or the testing script changed)

Models Affected

AESAES.Coursework.Tuning_brushup.MSL_electrical_thermal_OpenLoop (sim)Failed → Simulate
AixLibAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.NetworkCommunication2 (sim)Simulate performance 0:08:00 → 0.12
AixLib_latestAixLib.Controls.HVACAgentBasedControl.Examples.BookTrading.NetworkCommunication2 (sim)Simulate performance 0.12 → 0:08:00
Buildings_8Buildings.Obsolete.Utilities.IO.Python27.Functions.Examples.Exchange (sim)Compile → Simulate
Buildings_8Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection (sim)Simulate performance 0:08:00 → 0.14
Buildings_latestBuildings.Occupants.Office.Windows.Validation.Haldi2009WindowsTInTout (sim)Simulate → Verify
Buildings_latestBuildings.Occupants.Residential.AirConditioning.Validation.Ren2014ACLivingroom (sim)Simulate → Verify
IDEASIDEAS.Buildings.Components.Examples.LightingControl (sim)FrontEnd → Compile
IDEAS_devIDEAS.Examples.TwinHouses.BuildingN2_Exp1 (sim)FrontEnd → Compile
IDEAS_devIDEAS.Examples.TwinHouses.BuildingO5_Exp1_1Port (sim)FrontEnd → Compile
Modelica_DeviceDriversModelica_DeviceDrivers.Blocks.Examples.TestSerialPackager_UDPExternalTrigger (sim)Simulate → Compile
PowerGridsPowerGrids.Controls.Test.TestFirstOrderWithNonWindupLimiter (sim)Simulate → Compile
PowerGridsPowerGrids.Controls.Test.TestIntegratorWithNonWindupLimiter (sim)Simulate → Compile
PowerGridsPowerGrids.Electrical.Test.TestOneBusTransmissionLineWithBreakersOneLoad (sim)Templates → Simulate
PowerGridsPowerGrids.Electrical.Test.TestTransformerFixedRatioWithBreaker (sim)Templates → Simulate
PowerGridsPowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortA (sim)Templates → Simulate
PowerGridsPowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortB (sim)Templates → Simulate
PowerGridsPowerGrids.Electrical.Test.TestTwoBusesTwoLinesOneLoadOneBreakerOpenClosePortsAB (sim)Templates → Simulate
PowerGridsPowerGrids.Electrical.Test.TestTwoBusesTwoTransmLinesWithBreakersOneLoad (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busLine1to5Opening (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busLoad2Variation (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busPowerFlow (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busStaticNetwork (sim)Templates → Simulate
PowerGridsPowerGrids.Functions.Test.TestTimeConstants (sim)Templates → Simulate
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaIndividual_N_80_M_80 (sim)BackEnd performance 56.14 → 0:01:36