OpenModelica master from 2023-03-13 11:25:44 to 2023-03-13 23:18:32

Summary

OMC Commits2
Libraries Changed1
Number of Improvements14
Number of Regressions6
Number of Performance Improvements3
Number of Performance Regressions2

OpenModelica Changes

CommitAuthorSummary
74ee116f62bernhardbachmannKINSOL needs to have higher accuracy for some MSL models (#10399)
7a930eb42fPer ÖstlundIgnore missing modified elements in getModelInstance (#10393)

Library Changes

LibraryChange
PowerGridsConfiguration hash (OMC settings or the testing script changed)

Models Affected

Buildings_8Buildings.Obsolete.Utilities.IO.Python27.Functions.Examples.Exchange (sim)Simulate → Compile
Buildings_8Buildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection (sim)Simulate performance 0.16 → 0:08:00
Buildings_9Buildings.Occupants.BaseClasses.Validation.Weibull1DON (sim)Verify → Simulate
Buildings_9Buildings.Occupants.Office.Windows.Validation.Rijal2007WindowsTInTOutTComf (sim)Simulate → Verify
Buildings_9Buildings.Occupants.Residential.AirConditioning.Validation.Ren2014ACLivingroom (sim)Verify → Simulate
Buildings_latestBuildings.Experimental.DHC.EnergyTransferStations.Combined.Validation.ChillerBorefield (sim)Compile → Verify
Buildings_latestBuildings.Fluid.Geothermal.Borefields.BaseClasses.HeatTransfer.ThermalResponseFactors.Validation.GFunction_100boreholes (sim)Simulate → Verify
Buildings_latestBuildings.Occupants.BaseClasses.Validation.Weibull1DON (sim)Verify → Simulate
Buildings_latestBuildings.Occupants.Office.Windows.Validation.Rijal2007WindowsTInTOutTComf (sim)Simulate → Verify
Buildings_latestBuildings.Occupants.Residential.AirConditioning.Validation.Ren2014ACLivingroom (sim)Verify → Simulate
Buildings_latestBuildings.ThermalZones.Detailed.Examples.FFD.Tutorial.MixedConvection (sim)Simulate performance 0:08:00 → 0.16
IDEASIDEAS.Examples.Tutorial.Example8 (sim)BackEnd performance 11.29 → 5.44
IDEASIDEAS.Examples.Tutorial.Example9 (sim)BackEnd performance 11.75 → 5.53
IDEASIDEAS.Examples.TwinHouses.BuildingO5_Exp1_1Port (sim)FrontEnd → Simulate
IDEAS_devIDEAS.Buildings.Components.Examples.RectangularZoneRedeclarationWindows (sim)BackEnd performance 5.10 → 12.40
IDEAS_devIDEAS.Examples.TwinHouses.BuildingN2_Exp1 (sim)FrontEnd → Simulate
IDEAS_devIDEAS.Examples.TwinHouses.BuildingN2_Exp2 (sim)FrontEnd → Simulate
IDEAS_devIDEAS.Examples.TwinHouses.BuildingO5_Exp1_1Port (sim)FrontEnd → Simulate
PowerGridsPowerGrids.Electrical.Test.TestTerminalVoltageTransducerIEEE (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busGen2Disconnection (sim)FrontEnd → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busLine1to5Opening (sim)FrontEnd → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busLoad2Variation (sim)FrontEnd → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busPowerFlow (sim)Templates → Simulate
PowerGridsPowerGrids.Examples.IEEE14bus.IEEE14busStaticNetwork (sim)FrontEnd → Simulate
ScalableTestSuiteScalableTestSuite.Thermal.Advection.ScaledExperiments.SteamPipe_N_1280 (sim)Verify → Compile