OpenModelica master from 2018-11-14 22:16:30 to 2018-11-19 11:47:44

Summary

OMC Commits5
Libraries Changed1
Number of Improvements0
Number of Regressions3
Number of Performance Improvements9
Number of Performance Regressions11

OpenModelica Changes

CommitAuthorSummary
74a1cd4dacAdrian Popfix GC stats
d5e13f9293Lennart OchelSmall changes to Modelica export of linearized models
a616890f6dLennart OchelMake dummy states derivatives bidirectional
8fe98ae958hkielremove superfluous matchcontinue
565b72f5dehkielimprove doc generation speed

Library Changes

LibraryChange
ModelicaTest_trunk_cppFrom version trunk (revision 20181110-102401~git~master-om146) to trunk (revision 20181114-205806~git~master-om147)

Models Affected

ModelicaTest_3.2.1_cppModelicaTest.Media.TestsWithFluid.MediaTestModels.Air.MoistAir (sim)FrontEnd performance 11.18 → 19.51
ModelicaTest_3.2.1_cppModelicaTest.Media.TestsWithFluid.MediaTestModels.LinearFluid.LinearWater_pT (sim)FrontEnd performance 11.18 → 19.03
ModelicaTest_3.2.1_cppModelicaTest.Media.TestsWithFluid.MediaTestModels.Water.WaterIF97_pT (sim)FrontEnd performance 8.20 → 14.05
ModelicaTest_3.2.1_cppModelicaTest.Media.TestsWithFluid.MediaTestModels.Water.WaterIF97_ph (sim)FrontEnd performance 8.19 → 14.92
ModelicaTest_trunk_cppModelicaTest.Fluid.TestExamplesVariants.BranchingDynamicPipes_MomentumSteadyState (sim)FrontEnd performance 13.73 → 23.39
ModelicaTest_trunk_cppModelicaTest.Fluid.TestPipesAndValves.BranchingPipes1 (sim)Simulate performance 9.13 → 15.63
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_80_M_80 (sim)Verify → Failed
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_160_M_10 (sim)Simulate performance 8.48 → 16.62
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_320_M_5 (sim)Simulate performance 13.54 → 24.46
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_40_M_40 (sim)Simulate performance 7.13 → 15.64
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_80_M_20 (sim)Simulate performance 11.63 → 21.56
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_80_M_80 (sim)Verify → Failed
ScalableTestSuite_nooptScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_80_M_80 (sim)Verify → Failed
ScalableTestSuite_nooptScalableTestSuite.Elementary.WhenEvents.ScaledExperiments.ManyEvents_N_8000_M_10 (sim)Simulate performance 12.23 → 21.54
ThermoSysProThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim)FrontEnd performance 16.37 → 9.29 Templates performance 11.38 → 6.62
ThermoSysProThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim)FrontEnd performance 15.96 → 9.09 Templates performance 11.61 → 6.51
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim)Compile performance 23.47 → 12.75
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim)Compile performance 23.93 → 12.93
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim)BackEnd performance 11.04 → 6.11 Simulate performance 36.81 → 19.44
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim)Simulate performance 54.03 → 30.11
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim)Simulate performance 22.54 → 12.89
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim)Simulate performance 0:01:19 → 45.74
ThermoSysProThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim)Simulate performance 25.58 → 14.29