OpenModelica master from 2018-11-09 23:28:58 to 2018-11-10 23:11:16

Summary

OMC Commits1
Libraries Changed0
Number of Improvements0
Number of Regressions0
Number of Performance Improvements51
Number of Performance Regressions28

OpenModelica Changes

CommitAuthorSummary
7905e37cf5Per Östlund[NF] Fix NFFunction.mapExpParameter.

Library Changes

LibraryChange

Models Affected

Buildings_5.0.1Buildings.Controls.OBC.CDL.Psychrometrics.Validation.TDewPoi_TDryBulPhi (sim)FrontEnd performance 6.49 → 11.13
Buildings_5.0.1Buildings.Controls.OBC.CDL.Psychrometrics.Validation.TWetBul_TDryBulPhi (sim)FrontEnd performance 6.41 → 11.65
Buildings_latestBuildings.Fluid.HeatExchangers.BaseClasses.Examples.HexElementLatentLoop (sim)FrontEnd performance 24.43 → 13.73
Buildings_latestBuildings.Fluid.HeatExchangers.BaseClasses.Examples.HexElementSensible (sim)FrontEnd performance 18.96 → 10.70
Buildings_latestBuildings.Fluid.HeatExchangers.Examples.WetCoilDiscretizedPControl (sim)FrontEnd performance 0:01:39 → 58.36
Buildings_latestBuildings.Fluid.HeatExchangers.Validation.WetCoilDiscretizedInitialization (sim)BackEnd performance 10.48 → 3.79
Buildings_latestBuildings.Fluid.Humidifiers.Validation.SprayAirWasher_X (sim)FrontEnd performance 14.50 → 8.42
Buildings_latestBuildings.Fluid.Humidifiers.Validation.SprayAirWasher_X_dynamic (sim)FrontEnd performance 17.84 → 9.89
Buildings_latestBuildings.Fluid.Humidifiers.Validation.SteamHumidifier_X_dynamic (sim)FrontEnd performance 14.96 → 8.55
Buildings_latestBuildings.Fluid.MixingVolumes.BaseClasses.Validation.MixingVolumeHeatPortAir (sim)FrontEnd performance 14.66 → 8.39
Buildings_latestBuildings.Fluid.MixingVolumes.Examples.MixingVolumePrescribedHeatFlowRate (sim)FrontEnd performance 13.14 → 7.53
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.CoupledVolumesSpecializedAirPerfectGas (sim)FrontEnd performance 25.02 → 14.55
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolume (sim)FrontEnd performance 20.67 → 11.72
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolumeHeatReverseFlowPrescribedHeatFlowRate (sim)FrontEnd performance 14.75 → 8.51
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolumeInitialization (sim)FrontEnd performance 14.75 → 8.30
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolumeMassFlow (sim)FrontEnd performance 12.55 → 7.18
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolumeSteadyStateMass (sim)FrontEnd performance 13.43 → 7.41
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstance (sim)FrontEnd performance 15.44 → 8.97
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.MoistureMixingConservationDynamicBalance (sim)FrontEnd performance 19.56 → 11.31
Buildings_latestBuildings.Fluid.MixingVolumes.Validation.TraceSubstanceConservationSteadyState (sim)FrontEnd performance 14.97 → 8.65
Buildings_latestBuildings.Fluid.Movers.Examples.ClosedLoop_y (sim)FrontEnd performance 17.75 → 10.23
Buildings_latestBuildings.Fluid.Movers.Examples.SpeedControlled_y_pumpCurves (sim)FrontEnd performance 15.43 → 8.74 Compile performance 12.42 → 6.63
Buildings_latestBuildings.Fluid.Movers.Validation.ControlledFlowMachine (sim)FrontEnd performance 46.69 → 27.02 Compile performance 20.22 → 10.78
Buildings_latestBuildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic (sim)FrontEnd performance 48.19 → 26.94
Buildings_latestBuildings.Fluid.Movers.Validation.FlowControlled_dp (sim)FrontEnd performance 23.64 → 13.08 Compile performance 11.91 → 5.42
Buildings_latestBuildings.Fluid.Movers.Validation.FlowControlled_dpSystem (sim)FrontEnd performance 35.43 → 20.09
Buildings_latestBuildings.Fluid.Movers.Validation.FlowControlled_m_flow (sim)FrontEnd performance 23.55 → 13.12 Compile performance 10.94 → 5.57
Buildings_latestBuildings.Fluid.Movers.Validation.PowerExact (sim)FrontEnd performance 11.15 → 6.32 Compile performance 11.20 → 6.22
Buildings_latestBuildings.Fluid.Movers.Validation.PowerSimplified (sim)FrontEnd performance 10.04 → 5.67 Compile performance 10.85 → 5.57
Buildings_latestBuildings.Fluid.Movers.Validation.PumpCurveConstruction (sim)FrontEnd performance 14.87 → 8.08 Compile performance 11.92 → 6.22
IBPSA_latestIBPSA.Fluid.HeatExchangers.Examples.WaterHeater_u (sim)FrontEnd performance 6.33 → 11.04
IBPSA_latestIBPSA.Fluid.HeatExchangers.Validation.PrescribedOutlet_dynamic (sim)FrontEnd performance 7.52 → 12.92
IBPSA_latestIBPSA.Fluid.Humidifiers.Validation.SprayAirWasher_X (sim)FrontEnd performance 8.06 → 13.80
IBPSA_latestIBPSA.Fluid.MassExchangers.Validation.ConstantEffectivenessZeroFlow (sim)FrontEnd performance 10.02 → 17.18
IBPSA_latestIBPSA.Fluid.MixingVolumes.BaseClasses.Validation.MixingVolumeHeatMoisturePort (sim)FrontEnd performance 8.88 → 15.39
IBPSA_latestIBPSA.Fluid.MixingVolumes.BaseClasses.Validation.MixingVolumeHeatPortAir (sim)FrontEnd performance 8.15 → 14.01
IBPSA_latestIBPSA.Fluid.MixingVolumes.Examples.MixingVolumeHeatConduction (sim)FrontEnd performance 6.40 → 11.94
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.CoupledVolumesAir (sim)FrontEnd performance 7.85 → 13.39
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.CoupledVolumesSpecializedAirPerfectGas (sim)FrontEnd performance 14.11 → 24.02
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeHeatReverseFlow (sim)FrontEnd performance 7.42 → 13.10
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeHeatReverseFlowPrescribedHeatFlowRate (sim)FrontEnd performance 7.78 → 13.83
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeInitialization (sim)FrontEnd performance 7.72 → 13.79
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeMassFlow (sim)FrontEnd performance 6.72 → 11.55
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeMoistureReverseFlow (sim)FrontEnd performance 7.73 → 13.30
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeMoistureReverseFlowPrescribedHeatFlowRate (sim)FrontEnd performance 7.95 → 13.52
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeSteadyStateMass (sim)FrontEnd performance 7.09 → 12.07
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MixingVolumeTraceSubstance (sim)FrontEnd performance 7.93 → 13.93
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MoistureMixingConservationDynamicBalance (sim)FrontEnd performance 10.88 → 18.53
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.MoistureMixingConservationSteadyState (sim)FrontEnd performance 10.69 → 18.20
IBPSA_latestIBPSA.Fluid.MixingVolumes.Validation.TraceSubstanceConservationDynamicBalance (sim)FrontEnd performance 8.41 → 14.35
IBPSA_latestIBPSA.Fluid.Movers.Examples.ClosedLoop_y (sim)FrontEnd performance 9.44 → 16.12
IBPSA_latestIBPSA.Fluid.Movers.Examples.MoverParameter (sim)FrontEnd performance 7.64 → 13.25
IBPSA_latestIBPSA.Fluid.Movers.Examples.MoverStages (sim)FrontEnd performance 11.54 → 20.03
IBPSA_latestIBPSA.Fluid.Movers.Examples.SpeedControlled_y_pumpCurves (sim)FrontEnd performance 7.71 → 13.41
IBPSA_latestIBPSA.Fluid.Movers.Validation.FlowControlled_dp (sim)FrontEnd performance 12.96 → 22.40
IBPSA_latestIBPSA.Fluid.Movers.Validation.FlowControlled_m_flow (sim)FrontEnd performance 12.78 → 22.24
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestConstantHeatTransferTwoGrid_Fcoarse (sim)FrontEnd performance 12.34 → 6.93
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB (sim)FrontEnd performance 14.29 → 8.32
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestFlow1D2phDB_hf (sim)FrontEnd performance 14.62 → 8.59
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_A (sim)FrontEnd performance 15.17 → 8.65 Compile performance 14.45 → 8.38 Simulate performance 0:01:18 → 43.78
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_B (sim)FrontEnd performance 14.80 → 8.57 Compile performance 15.08 → 8.28 Simulate performance 42.86 → 23.45
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_C (sim)FrontEnd performance 14.70 → 8.47 Compile performance 14.86 → 8.03 Simulate performance 34.89 → 19.29
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_D (sim)FrontEnd performance 14.82 → 8.26 Compile performance 14.35 → 8.13
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_E (sim)FrontEnd performance 16.86 → 9.59
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFEM_F (sim)BackEnd performance 10.30 → 5.55
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_A (sim)FrontEnd performance 14.51 → 8.41
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_B (sim)FrontEnd performance 14.28 → 8.27
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_C (sim)FrontEnd performance 14.77 → 8.38
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV2ph_D (sim)FrontEnd performance 14.46 → 8.34
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A (sim)FrontEnd performance 14.97 → 8.68
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_A_Fast (sim)FrontEnd performance 21.79 → 12.41
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_B (sim)FrontEnd performance 14.59 → 8.37
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_D (sim)FrontEnd performance 14.35 → 8.21
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_DB (sim)FrontEnd performance 14.83 → 8.45 Compile performance 11.34 → 6.32
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_E (sim)FrontEnd performance 17.64 → 10.06 Compile performance 22.05 → 12.68
ThermoPowerThermoPower.Test.DistributedParameterComponents.TestWaterFlow1DFV_F (sim)Compile performance 25.76 → 14.89
ThermoPowerThermoPower.Test.GasComponents.TestTurboJetInertia (sim)FrontEnd performance 12.86 → 7.20
ThermoPowerThermoPower.Test.WaterComponents.TestCoolingTower (sim)FrontEnd performance 14.77 → 8.30
ThermoPowerThermoPower.Test.WaterComponents.TestMixerSlowFastSteam (sim)FrontEnd performance 14.69 → 8.60