OpenModelica master from 2017-01-18 23:14:09 to 2017-01-20 03:33:20

Summary

OMC Commits7
Libraries Changed3
Number of Improvements5
Number of Regressions35
Number of Performance Improvements4
Number of Performance Regressions1

OpenModelica Changes

CommitAuthorSummary
4fe59c4ab0Martin SjölundFollow FMI 2.0 schema (no empty output section)
6ed4cfdbdbLennart OchelDon't use default matching arguments within postOptimizeDAE
b894ea2c8fLennart OchelNew index reduction method "none"
0c828c123dLennart OchelFix new runtime flags (#1383)
b0da1de61bWilli Braunfix row jac norm sum
8788348c00Willireset BackendDAE after replace simplifid expressions for lambda=0
0ed97dad84Williadded -nlssMaxDensity and -nlssMinSize simulation flags

Library Changes

LibraryChange
Annex60From version 1.0.0 (revision 1.0.0-20170117-154852~git~master) to 1.0.0 (revision 1.0.0-15-g4e716ab)
Buildings_latestFrom version 4.0.0 (revision 20170117-115353~git~master) to 4.0.0 (revision 20170118-145617~git~master)
PowerSystems_cppFrom version 0.5.0 (revision 0.5.0) to 0.6.0 (revision 0.6.0)

Models Affected

Annex60Annex60.Fluid.Movers.Examples.ClosedLoop_y (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Examples.PumpsParallel (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Examples.PumpsSeries (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Examples.SpeedControlled_y_pumpCurves (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.ControlledFlowMachine (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.ControlledFlowMachineDynamic (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.PowerExact (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.PowerSimplified (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.PumpCurveConstruction (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.Pump_stratos (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.SpeedControlled_Nrpm (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.SpeedControlled_y (sim)Simulate → BackEnd
Annex60Annex60.Fluid.Movers.Validation.SpeedControlled_y_linear (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.HeatExchangers.Ground.Boreholes.Examples.UTube (sim)Simulate performance 19.44 → 9.12
Buildings_latestBuildings.Fluid.Movers.Examples.ClosedLoop_y (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Examples.PumpsParallel (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Examples.PumpsSeries (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Examples.SpeedControlled_y_pumpCurves (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.ControlledFlowMachine (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.ControlledFlowMachineDynamic (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.PowerExact (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.PowerSimplified (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.PumpCurveConstruction (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.Pump_stratos (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.SpeedControlled_Nrpm (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.SpeedControlled_y (sim)Simulate → BackEnd
Buildings_latestBuildings.Fluid.Movers.Validation.SpeedControlled_y_linear (sim)Simulate → BackEnd
Modelica_3.1Modelica.Electrical.Analog.Examples.CauerLowPassSC (sim)Simulate performance 0:01:20 → 42.85
Modelica_3.2.1Modelica.Fluid.Examples.PumpingSystem (sim)Simulate → FrontEnd
Modelica_3.2.1_cppModelica.Electrical.Spice3.Examples.Spice3BenchmarkFourBitBinaryAdder (sim)Simulate performance 36.35 → 0:01:17
Modelica_3.2.1_cppModelica.Fluid.Examples.PumpingSystem (sim)Simulate → FrontEnd
Modelica_3.2.2Modelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_YD (sim)Simulate performance 54.95 → 25.61
Modelica_3.2.2Modelica.Fluid.Examples.IncompressibleFluidNetwork (sim)Verify → Compile
Modelica_3.2.2Modelica.Fluid.Examples.PumpingSystem (sim)Simulate → FrontEnd
Modelica_3.2.2_cppModelica.Fluid.Examples.PumpingSystem (sim)Simulate → FrontEnd
Modelica_trunkModelica.Electrical.Machines.Examples.AsynchronousInductionMachines.AIMC_YD (sim)Simulate performance 50.16 → 25.71
Modelica_trunkModelica.Fluid.Examples.IncompressibleFluidNetwork (sim)Compile → Verify
Modelica_trunkModelica.Fluid.Examples.PumpingSystem (sim)Simulate → FrontEnd
Modelica_trunkModelica.StateGraph.Examples.FirstExample_Variant2 (sim)Templates → Verify
Modelica_trunk_cppModelica.Fluid.Examples.PumpingSystem (sim)Simulate → FrontEnd
PowerSystems_cppPowerSystems.Examples.PowerWorld.PowerWorld (sim)Compile → Simulate
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemAC.ScaledExperiments.DistributionSystemLinearIndividual_N_40_M_40 (sim)Compile → Failed
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelicaActiveLoads_N_80_M_80 (sim)Templates → Compile
ScalableTestSuiteScalableTestSuite.Electrical.DistributionSystemDC.ScaledExperiments.DistributionSystemModelica_N_80_M_80 (sim)Compile → Simulate
ThermoPowerThermoPower.PowerPlants.ElectricGeneratorGroup.Tests.Test_Generator_SE_com (sim)Simulate → Templates