OpenModelica master-fmi from 2025-12-07 06:29:14 to 2025-12-08 23:05:23

Summary

OMC Commits0
Libraries Changed2
Number of Improvements7
Number of Regressions7
Number of Performance Improvements3
Number of Performance Regressions0

OpenModelica Changes

CommitDateAuthorSummary

OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
a8b7fb32025-12-04 12:35:20 +0100Adrian Popupdate HelmholtzMedia (#261)
9ff46942025-12-01 19:08:02 +0100Francesco CasellaAdd flag to scalarize systems (#259)

Library Changes

LibraryChange
Buildings_11Configuration hash (OMC settings or the testing script changed)
Buildings_12Configuration hash (OMC settings or the testing script changed)

Models Affected

Buildings_11Buildings.DHC.ETS.Combined.Validation.ChillerWSE (sim)Failed → Verify
Buildings_11Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case600FF (sim)Verify → Failed
Buildings_11Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case650FF (sim)Verify → Failed
Buildings_11Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case660 (sim)Failed → Compile
Buildings_11Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case900 (sim)Failed → Compile
Buildings_11Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade (sim)Failed → Verify
Buildings_12Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimaryLoadSideEconomizer (sim)Compile performance 0:02:41 → 0:01:30
Buildings_12Buildings.Applications.DataCenters.ChillerCooled.Examples.IntegratedPrimarySecondaryEconomizer (sim)Compile performance 0:04:12 → 0:02:26
Buildings_12Buildings.Applications.DataCenters.ChillerCooled.Examples.NonIntegratedPrimarySecondaryEconomizer (sim)Compile performance 0:03:39 → 0:01:57
Buildings_12Buildings.DHC.ETS.Combined.Examples.ChillerOnly (sim)Verify → Failed
Buildings_12Buildings.DHC.ETS.Combined.Validation.ChillerOnly (sim)Failed → Simulate
Buildings_12Buildings.Fluid.HeatExchangers.Validation.WetCoilEffectivenessNTUCounterFlow (sim)Verify → Failed
Buildings_12Buildings.Fluid.HeatExchangers.Validation.WetCoilEffectivenessNTUHeating (sim)Verify → Failed
Buildings_12Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case680FF (sim)Verify → Failed
Buildings_12Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases6xx.Case685 (sim)Simulate → Failed
Buildings_12Buildings.ThermalZones.Detailed.Validation.BESTEST.Cases9xx.Case910 (sim)Failed → Compile
Buildings_12Buildings.ThermalZones.Detailed.Validation.TestConditionalConstructions.OnlyExteriorWallWithWindowExteriorShade (sim)Failed → Verify