startTime=0 stopTime=20 tolerance=1e-06 numberOfIntervals=2500 stepSize=0.008 wasm-jit simulation: simulate(LargeTestSuite.Thermal.HeatExchanger.CounterCurrentHeatExchangerEquations_N_10240,startTime=0,stopTime=20,tolerance=1e-06,numberOfIntervals=2500,outputFormat="empty",variableFilter="",fileNamePrefix="LargeTestSuite_NB_simvec_LargeTestSuite.Thermal.HeatExchanger.CounterCurrentHeatExchangerEquations_N_10240",simflags="-s=ida -abortSlowSimulation -alarm=400 -lv LOG_STATS") LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0s reading init.xml | | | | | | 0s reading info.xml | | | | | | 8.2754e-05s [ 0.0%] pre-initialization | | | | | | 0.00121546s [ 0.0%] initialization | | | | | | 0s [ 0.0%] steps | | | | | | 3.56011s [ 41.0%] solver (excl. callbacks) | | | | | | 0.112672s [ 1.3%] creating output-file | | | | | | 0.00142545s [ 0.0%] event-handling | | | | | | 0s [ 0.0%] overhead | | | | | | 5.00775s [ 57.7%] simulation | | | | | | 8.68325s [100.0%] total | | | | | events | | | | | | 2 state events | | | | | | 0 time events | | | | | solver: ida | | | | | | 5685 steps taken | | | | | | 7674 calls of functionODE | | | | | | 188 evaluations of jacobian | | | | | | 2 error test failures | | | | | | 0 convergence test failures | | | | | | 0.268807s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully.