ThermoSysPro test using OpenModelica

Total Frontend Backend SimCode Templates Compilation Simulation Verification
245 245 237 237 237 234 187 0

Test started: 2026-08-29 15:42:34
Total time taken: 4:34:33
System info: ryzen-5950x-1: AMD Ryzen 9 5950X 16-Core Processor, 63 GB RAM, Ubuntu 26.04.1 LTS

OpenModelica Version: OMCompiler v1.28.0-dev.498+g0a491ef158
OpenModelicaLibraryTesting Changes

CommitDateAuthorSummary
b5363912026-08-28 21:36:43 +0200Martin SjölundRun master, cvode, gbode and ida as one job (#342)

Tested Library: ThermoSysPro 4.2

{
 "path": "ThermoSysPro",
 "sha": "a896ab75ce22162369e7fa4ce79927eeca44ad4a",
 "support": "noSupport",
 "version": "4.2.0-master",
 "zipfile": "https://gitlab.pam-retd.fr/thermosysproandco/ThermoSysPro/-/archive/a896ab75ce22162369e7fa4ce79927eeca44ad4a/ThermoSysPro-a896ab75ce22162369e7fa4ce79927eeca44ad4a.zip"
}

BuildModel time limit: 660s
Simulation time limit: 480s
Default tolerance: 1e-06
Default number of intervals: 2500
Optimization level: Tool default

Flags:
setCommandLineOptions("-d=nogen");
setCommandLineOptions("-d=initialization");
setCommandLineOptions("-d=backenddaeinfo");
setCommandLineOptions("-d=discreteinfo");
setCommandLineOptions("-d=stateselection");
setCommandLineOptions("-d=execstat");
setMatchingAlgorithm("PFPlusExt");
setIndexReductionMethod("dynamicStateSelection");
Config:
{
 "library": "ThermoSysPro",
 "libraryVersion": "master",
 "libraryVersionNameForTests": ""
}

Links are provided if getErrorString() or the simulation generates output. The links are coded with red if there were errors, yellow if there were warnings, and normal links if there are only notifications.

ModelVerifiedSimulateTotal buildModelParsingFrontendBackendSimCodeTemplatesCompileTotal Execution
ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 31.2394.090.943.7715.311.483.9169.61650.92
ThermoSysPro.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 134.9094.600.963.8615.491.693.2070.35705.04
ThermoSysPro.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 0.3486.610.932.8717.731.273.0461.7189.22
ThermoSysPro.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.0022.660.943.079.150.652.087.7224.15
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.156.871.111.850.250.010.214.549.09
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 0.086.830.941.840.240.010.214.538.62
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 0.348.170.922.220.560.010.185.2010.95
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.527.120.931.900.250.010.214.7510.14
ThermoSysPro.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.307.271.021.840.280.010.424.7310.52
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding 0.003.170.952.920.250.000.000.004.78
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow 0.003.200.942.960.240.000.000.004.82
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow 0.003.130.962.890.230.000.000.004.75
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 1.8811.190.932.090.930.050.257.8618.85
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 0.3511.130.942.040.550.090.448.0113.73
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 34.2216.940.942.061.550.160.6812.49119.26
ThermoSysPro.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.048.350.932.050.280.030.425.5710.01
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.077.170.952.050.230.020.264.628.97
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.107.160.942.060.210.010.254.649.02
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.077.100.952.050.210.020.254.578.83
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.117.101.032.070.210.010.254.558.98
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 2.427.180.922.030.220.020.254.6621.02
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 9.828.400.962.250.590.020.195.36159.98
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.568.330.962.300.340.020.335.3411.79
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.077.080.942.060.210.010.254.558.83
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.208.260.932.260.550.010.185.2610.43
ThermoSysPro.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 0.267.650.952.050.260.020.454.8710.39
ThermoSysPro.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 22.8742.220.962.195.680.681.3132.36115.44
ThermoSysPro.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 0.149.110.942.070.270.020.426.3211.09
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 33.7118.200.942.311.760.170.5313.43625.43
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.187.720.932.050.220.020.464.979.79
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.038.620.942.240.620.020.185.5610.27
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.137.460.942.060.210.020.254.919.39
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.1516.141.002.291.510.160.4911.7018.24
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.227.400.972.050.200.020.254.889.64
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestTank (sim) 0.958.600.962.280.610.020.185.5113.21
ThermoSysPro.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 0.848.280.932.240.520.010.175.3312.56
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 3.1693.330.953.8515.521.463.4769.02104.50
ThermoSysPro.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 0.5191.510.943.7915.361.722.8867.7594.66
ThermoSysPro.Examples.SimpleExamples.TestAirHumidity (sim) 0.045.070.932.110.040.010.202.726.71
ThermoSysPro.Examples.SimpleExamples.TestBend (sim) 0.077.160.962.060.230.020.254.618.93
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump (sim) 1.177.400.962.020.170.020.254.9450.88
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.117.190.962.030.150.020.254.739.10
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump2 (sim) 0.338.180.952.240.570.010.175.1911.05
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump3 (sim) 1.418.350.942.230.520.020.185.4014.53
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump4 (sim) 1.378.340.932.200.510.020.185.4313.81
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump5 (sim) 0.476.950.931.830.290.020.244.589.81
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump6 (sim) 0.448.180.932.250.570.020.185.1711.28
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump7 (sim) 369.558.290.932.040.350.030.405.46805.59
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump8 (sim) 0.086.990.951.840.250.010.204.688.79
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump9 (sim) 0.066.830.921.820.250.010.204.548.54
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump10 (sim) 0.167.680.962.020.290.020.434.929.73
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump11 (sim) 0.238.190.932.230.550.020.185.2110.45
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump12 (sim) 0.116.890.931.850.240.010.204.588.84
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPump13 (sim) 0.166.740.931.840.240.010.204.458.64
ThermoSysPro.Examples.SimpleExamples.TestCentrifugalPumpWaterSolution (sim) 0.034.720.951.780.030.030.272.606.38
ThermoSysPro.Examples.SimpleExamples.TestCheckValve (sim) 0.798.950.972.240.630.020.195.8614.08
ThermoSysPro.Examples.SimpleExamples.TestCompressor (sim) 0.059.750.932.250.300.160.196.8411.42
ThermoSysPro.Examples.SimpleExamples.TestControlValve (sim) 0.076.940.952.030.210.010.244.458.65
ThermoSysPro.Examples.SimpleExamples.TestDiaphragm (sim) 0.076.970.942.050.210.010.244.478.69
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump (sim) 62.727.230.932.000.140.020.254.81123.89
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump1 (sim) 1.617.270.982.030.150.020.254.8214.08
ThermoSysPro.Examples.SimpleExamples.TestDynamicCentrifugalPump2 (sim) 0.748.320.942.080.340.030.395.4814.57
ThermoSysPro.Examples.SimpleExamples.TestDynamicCheckValve (sim) 2.267.180.932.010.220.020.244.6920.78
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum (sim) 2.1218.040.962.271.690.160.5113.4131.35
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum1 (sim) 2.1618.130.942.291.730.160.5113.4531.96
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum2 (sim) 13.0218.340.942.311.730.160.5113.63567.72
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum3 (sim) 2.1118.230.942.301.850.160.5113.4131.43
ThermoSysPro.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 32.8318.410.952.291.750.170.5113.69627.60
ThermoSysPro.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 0.9011.000.952.020.480.080.398.0416.35
ThermoSysPro.Examples.SimpleExamples.TestDynamicReliefValve (sim) 1.848.490.952.230.570.020.185.4917.82
ThermoSysPro.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 32.9526.350.952.122.970.300.8220.14127.77
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 8.0334.780.962.834.900.311.2025.5472.06
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterHeating_Islanding 0.003.060.942.840.220.000.000.004.62
ThermoSysPro.Examples.SimpleExamples.TestDynamicWaterWaterExchanger (sim) 0.268.680.941.830.420.040.366.0211.85
ThermoSysPro.Examples.SimpleExamples.TestFan 0.002.740.952.150.590.000.000.004.30
ThermoSysPro.Examples.SimpleExamples.TestFan_Pin 0.002.820.952.120.700.000.000.004.39
ThermoSysPro.Examples.SimpleExamples.TestFan_Qin 0.002.700.942.110.590.000.000.004.27
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesJunctions (sim) 0.055.010.942.100.050.010.192.666.70
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes (sim) 0.185.970.932.110.120.020.383.348.08
ThermoSysPro.Examples.SimpleExamples.TestFlueGasesVolumes1 0.003.121.072.090.160.020.390.464.74
ThermoSysPro.Examples.SimpleExamples.TestFresnelField (sim) 39.3942.510.942.205.840.501.6432.33141.18
ThermoSysPro.Examples.SimpleExamples.TestIdealCheckValve (sim) 0.689.100.952.250.720.020.225.8913.76
ThermoSysPro.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.178.080.952.210.550.010.185.1410.12
ThermoSysPro.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.066.940.942.010.180.010.244.498.65
ThermoSysPro.Examples.SimpleExamples.TestJunctions1 (sim) 0.328.100.942.040.270.020.415.3710.55
ThermoSysPro.Examples.SimpleExamples.TestJunctions2 (sim) 0.428.470.942.030.310.030.405.7011.18
ThermoSysPro.Examples.SimpleExamples.TestJunctions3 (sim) 2.388.600.942.240.580.020.185.5917.30
ThermoSysPro.Examples.SimpleExamples.TestJunctions4 (sim) 0.207.710.942.060.320.020.424.909.85
ThermoSysPro.Examples.SimpleExamples.TestJunctions5 (sim) 2.339.030.942.290.630.020.195.9017.42
ThermoSysPro.Examples.SimpleExamples.TestLoopBreaker (sim) 0.126.920.941.840.240.010.204.638.82
ThermoSysPro.Examples.SimpleExamples.TestLumpedStraightPipe (sim) 1.638.360.932.220.340.020.315.4716.07
ThermoSysPro.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.136.940.961.860.230.010.204.648.86
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating0 (sim) 12.048.320.962.060.340.020.395.5145.67
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating1 (sim) 13.258.330.972.060.260.020.455.5448.64
ThermoSysPro.Examples.SimpleExamples.TestNTUWaterHeating2 (sim) 21.699.180.932.040.350.040.386.3775.91
ThermoSysPro.Examples.SimpleExamples.TestPipePressureLoss (sim) 0.077.100.952.050.210.010.234.618.82
ThermoSysPro.Examples.SimpleExamples.TestPressurizer_CC (sim) 0.038.640.952.250.620.020.185.5710.30
ThermoSysPro.Examples.SimpleExamples.TestRefP (sim) 0.118.100.942.250.320.010.315.219.96
ThermoSysPro.Examples.SimpleExamples.TestSensors (sim) 0.168.030.982.280.550.010.185.0110.08
ThermoSysPro.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.166.920.952.160.120.010.374.278.93
ThermoSysPro.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.247.100.941.820.310.010.404.569.34
ThermoSysPro.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.067.090.962.030.210.010.244.608.87
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump (sim) 0.287.250.941.850.310.020.244.8410.35
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 0.057.330.932.250.220.010.244.619.00
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPump2 (sim) 0.407.400.931.830.280.010.414.8710.39
ThermoSysPro.Examples.SimpleExamples.TestStaticCentrifugalPumpWaterSolution (sim) 0.034.780.941.810.030.030.292.636.42
ThermoSysPro.Examples.SimpleExamples.TestStaticCondenser (sim) 0.448.381.022.060.280.020.415.6111.41
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.037.350.982.090.210.020.264.778.99
ThermoSysPro.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.257.600.942.040.200.020.265.079.86
ThermoSysPro.Examples.SimpleExamples.TestStaticExchangerWaterSteamFlueGases (sim) 0.147.230.932.150.110.010.374.599.15
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchanger (sim) 0.117.430.931.820.340.010.394.869.32
ThermoSysPro.Examples.SimpleExamples.TestStaticWaterWaterExchangerDTorWorEff (sim) 0.227.080.941.830.290.010.444.509.24
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.197.590.932.040.220.020.454.879.71
ThermoSysPro.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.227.250.952.030.190.010.254.779.49
ThermoSysPro.Examples.SimpleExamples.TestSteamEngine (sim) 0.108.090.942.040.150.020.265.629.95
ThermoSysPro.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.227.610.942.050.230.210.254.869.84
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine (sim) 0.809.840.952.080.340.030.436.9614.38
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 0.219.430.962.100.320.020.416.5811.99
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 0.169.030.932.070.270.020.426.2611.06
ThermoSysPro.Examples.SimpleExamples.TestStodolaTurbine3 (sim) 0.269.410.942.080.310.020.426.5811.73
ThermoSysPro.Examples.SimpleExamples.TestSwitchValve (sim) 0.208.260.962.240.560.010.175.2810.40
ThermoSysPro.Examples.SimpleExamples.TestTank (sim) 0.888.520.942.240.600.020.195.4713.08
ThermoSysPro.Examples.SimpleExamples.TestThreeWayValve (sim) 0.277.710.972.050.260.020.444.9410.58
ThermoSysPro.Examples.SimpleExamples.TestVolumeATh (sim) 0.868.200.942.300.530.010.175.1912.44
ThermoSysPro.Examples.SimpleExamples.TestVolumes (sim) 2.839.060.942.290.640.020.205.9218.86
ThermoSysPro.Examples.SimpleExamples.TestVolumes1 (sim) 2.819.020.942.250.640.020.205.9118.78
ThermoSysPro.Examples.SimpleExamples.TestVolumes2 (sim) 6.759.090.952.270.630.020.195.9831.86
ThermoSysPro.Examples.SimpleExamples.TestWirelessSensor (sim) 0.858.660.952.230.630.030.195.5813.50
ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.GasTurbineTrip (sim) 30.3893.510.953.7615.231.514.1068.91648.82
ThermoSysPro.Fluid.Examples.Book.PowerPlants.CombinedCyclePowerPlant.LoadVariation (sim) 131.5293.970.933.7815.401.733.4769.59678.32
ThermoSysPro.Fluid.Examples.Book.PowerPlants.ConcentratedSolarPowerPlant_PTSC (sim) 0.32110.210.933.6231.071.623.0970.81112.77
ThermoSysPro.Fluid.Examples.Book.PowerPlants.SupercriticalPulverizedCoalPowerPlant 0.0022.390.923.049.010.652.027.6723.83
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_1 (sim) 0.207.450.942.220.380.150.174.549.62
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_2 (sim) 0.137.510.942.180.380.150.164.659.47
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_3 (sim) 0.398.530.952.280.660.010.185.3911.66
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestCentrifugalPump.Scenario_4 (sim) 0.717.490.942.190.370.150.174.6211.02
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.CentrifugalPump.TestStaticCentrifugalPump (sim) 0.417.880.932.220.620.010.174.8510.95
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.Islanding (sim) 480.0931.900.952.766.890.281.0420.931464.23
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.NegativeFlow (sim) 480.0931.690.922.686.830.271.0120.911473.53
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.DynamicWaterHeater.ZeroFlow (sim) 480.0931.780.912.927.030.260.9620.611457.60
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicCondenser (sim) 0.7812.250.942.331.800.040.457.6316.23
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicOnePhaseFlowShell (sim) 0.1311.390.922.231.180.190.237.5613.30
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestDynamicTwoPhaseFlowPipe (sim) 0.0918.020.922.281.660.160.5413.3719.81
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.HeatExchanger.TestStaticCondenser (sim) 0.049.090.942.290.880.020.365.5410.74
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestBend (sim) 0.218.130.952.440.510.010.185.0010.16
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestCheckValve (sim) 0.107.650.932.200.280.010.324.849.49
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestControlValve (sim) 0.097.660.962.260.290.010.334.779.51
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDiaphragm (sim) 0.118.030.952.230.500.010.175.129.97
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDynamicCheckValve (sim) 2.297.490.932.210.290.010.314.6721.31
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestDynamicReliefValve (sim) 5.258.720.922.220.780.010.185.52101.90
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestLumpedStraightPipe (sim) 0.678.610.932.250.800.020.185.3612.34
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestPipePressureLoss (sim) 0.127.380.932.180.280.010.314.609.21
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestSwitchValve (sim) 0.378.310.942.250.640.010.185.2411.00
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.PressureLoss.TestThreeWayValve (sim) 0.708.030.942.250.610.010.184.9811.59
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.SolarCollector.TestFresnelField (sim) 25.3844.950.942.865.610.681.2534.55132.15
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.SteamTurbine.TestStodolaTurbine (sim) 0.189.490.942.260.270.020.346.6111.62
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestDynamicDrum (sim) 37.3919.580.952.332.280.290.5414.15705.56
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestMixer3 (sim) 0.358.200.952.260.660.010.175.0910.93
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestPressurizer (sim) 0.039.130.952.250.890.020.385.5910.75
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSplitter3 (sim) 0.298.410.942.240.810.010.175.1810.79
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestStaticDrum3 (sim) 0.1117.700.932.382.370.150.5012.3119.54
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestSteamDryer (sim) 0.428.200.932.230.870.010.174.9310.96
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestTank (sim) 1.048.940.932.320.820.020.195.6014.11
ThermoSysPro.Fluid.Examples.Book.SimpleExamples.Volume.TestVolumeATh (sim) 0.788.660.942.230.960.010.365.0912.82
ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_Load_100_50 (sim) 4.0998.690.904.2519.111.723.1670.45112.64
ThermoSysPro.Fluid.Examples.CombinedCyclePowerPlant.CombinedCycle_TripTAC (sim) 0.3495.370.923.9217.591.433.2769.1798.00
ThermoSysPro.Fluid.Examples.SimpleExamples.TestAirHumidity (sim) 0.027.650.912.150.500.010.174.819.21
ThermoSysPro.Fluid.Examples.SimpleExamples.TestBend (sim) 0.127.670.902.200.490.010.164.809.53
ThermoSysPro.Fluid.Examples.SimpleExamples.TestCHPEngineBarkantineSystem (sim) 0.749.290.902.211.140.020.325.6013.01
ThermoSysPro.Fluid.Examples.SimpleExamples.TestCentrifugalPump1 (sim) 0.197.460.892.140.590.010.164.559.49
ThermoSysPro.Fluid.Examples.SimpleExamples.TestCheckValve (sim) 0.908.941.052.200.810.020.375.5415.69
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiaphragm (sim) 0.127.800.922.190.490.010.164.959.67
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicOnePhaseFlowPipe (sim) 0.1214.741.002.291.520.080.4410.4216.71
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicPlateHeatExchanger (sim) 3.7012.250.922.241.350.100.268.3024.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_DynamicTwoPhaseFlowPipe (sim) 0.1526.660.942.322.610.430.8320.4728.64
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDiffusion_VolumeA (sim) 0.208.020.922.170.560.010.165.1210.17
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicCheckValve (sim) 2.177.480.902.180.290.010.304.6921.56
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicCondenser (sim) 0.8916.490.942.392.450.070.4511.1320.75
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicDrum (sim) 1.8518.070.912.281.860.280.7812.8825.12
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicDrum_CC (sim) 35.3019.070.912.312.130.170.5313.93692.15
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicFlueGasesMultiFluidHeatExchanger (sim) 1.1713.400.942.241.370.080.489.2421.06
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicMultiFluidHeatExchanger (sim) 2.3210.970.942.251.360.040.227.0919.58
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicMultiFluidHeatExchangerShell (sim) 1.5911.040.922.271.390.040.237.1117.22
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicOnePhaseFlowPipe (sim) 3.5011.460.922.241.380.040.237.5632.36
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicPlateHeatExchanger (sim) 4.0313.560.932.301.610.110.449.1027.31
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicReliefValve (sim) 1.558.770.932.240.750.020.215.5524.37
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicTwoPhaseFlowPipe (sim) 0.1427.020.932.353.150.300.8520.3828.98
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicTwoPhaseFlowRiser (sim) 0.3017.500.922.291.500.160.5113.0520.12
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeating (sim) 106.3631.200.922.675.590.270.9421.72296.21
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterHeatingOnePipe (sim) 23.2521.800.942.613.640.350.5914.60100.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestDynamicWaterSteamMultiFluidHeatExchanger (sim) 1.3614.170.942.301.840.090.439.5119.80
ThermoSysPro.Fluid.Examples.SimpleExamples.TestFixedPowerHeatExchanger (sim) 0.087.900.922.190.210.010.335.169.67
ThermoSysPro.Fluid.Examples.SimpleExamples.TestFresnelField (sim) 44.5344.920.922.805.940.501.3934.30164.77
ThermoSysPro.Fluid.Examples.SimpleExamples.TestGasTurbine (sim) 1.208.030.922.220.410.020.175.2113.12
ThermoSysPro.Fluid.Examples.SimpleExamples.TestIdealCheckValve (sim) 1.059.180.922.250.840.020.365.7114.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestIdealSwitchValve (sim) 0.318.400.922.270.650.010.175.2910.89
ThermoSysPro.Fluid.Examples.SimpleExamples.TestInvSingularPressureLoss (sim) 0.098.210.932.430.800.010.164.8110.00
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions1 (sim) 0.628.880.942.260.970.020.355.2812.28
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions2 (sim) 0.798.790.942.260.760.020.195.5712.73
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions3 (sim) 5.969.380.922.270.970.020.335.7930.90
ThermoSysPro.Fluid.Examples.SimpleExamples.TestJunctions4 (sim) 0.308.060.922.210.650.010.175.0210.50
ThermoSysPro.Fluid.Examples.SimpleExamples.TestLoopBreaker (sim) 0.237.810.942.210.650.010.174.7610.01
ThermoSysPro.Fluid.Examples.SimpleExamples.TestMassFlowMultiplier (sim) 0.387.750.922.200.700.010.174.6710.07
ThermoSysPro.Fluid.Examples.SimpleExamples.TestNTUWaterHeater0 (sim) 0.579.111.012.231.070.020.325.4712.44
ThermoSysPro.Fluid.Examples.SimpleExamples.TestPressurizer (sim) 0.038.700.922.250.870.020.195.3910.32
ThermoSysPro.Fluid.Examples.SimpleExamples.TestRefP (sim) 0.208.400.942.250.770.010.185.1910.57
ThermoSysPro.Fluid.Examples.SimpleExamples.TestRefP1 (sim) 0.238.200.932.230.780.010.175.0110.39
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSensors (sim) 0.238.250.972.230.640.010.175.2010.60
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser (sim) 0.359.290.982.280.930.020.355.7111.93
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleDynamicCondenser1 (sim) 0.7111.270.932.290.930.030.367.6614.88
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleEvaporatorWaterSteamFlueGases (sim) 0.208.560.952.220.860.010.185.2910.75
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSimpleStaticCondenser (sim) 0.247.970.932.290.160.020.335.1710.21
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSingularPressureLoss (sim) 0.097.520.932.220.200.010.324.789.32
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticAerocondenser (sim) 0.408.850.932.230.930.010.345.3411.59
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCentrifugalPump1 (sim) 0.077.510.952.200.220.010.334.759.26
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCondenser (sim) 0.629.070.932.250.860.020.365.5812.46
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticCondenserHEI (sim) 0.709.320.922.250.900.020.355.8012.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticDrum1 (sim) 0.037.780.992.270.530.010.174.819.46
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticDrum2 (sim) 0.387.900.952.220.590.010.174.9110.66
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticExchangerDTorWorEff (sim) 0.337.780.942.220.570.010.174.8110.30
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticExchangerKS (sim) 0.617.750.932.200.520.010.174.8511.10
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticFan 0.003.160.922.250.910.000.000.004.71
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticPlateHeatExchanger (sim) 0.128.120.932.230.190.020.345.3410.02
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStaticWallFlueGasesExchanger (sim) 0.368.970.922.250.480.020.206.0111.56
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamDryer1 (sim) 0.358.460.942.250.870.010.175.1511.08
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamDryer2 (sim) 0.418.340.932.240.910.020.284.8911.05
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamEngine (sim) 0.159.350.942.260.250.020.336.5011.36
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSteamExtractionSplitter (sim) 0.428.190.942.210.650.010.175.1410.99
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStodolaTurbine1 (sim) 0.039.920.952.240.640.020.196.8311.58
ThermoSysPro.Fluid.Examples.SimpleExamples.TestStodolaTurbine2 (sim) 0.199.480.942.320.270.020.336.5311.65
ThermoSysPro.Fluid.Examples.SimpleExamples.TestSwitchValve (sim) 0.368.580.942.240.680.010.195.4511.37
ThermoSysPro.Fluid.Examples.SimpleExamples.TestTank (sim) 0.958.870.962.290.830.020.185.5414.27
ThermoSysPro.Fluid.Examples.SimpleExamples.TestTankHorizontal (sim) 2.1610.100.932.310.940.020.386.4519.97
ThermoSysPro.Fluid.Examples.SimpleExamples.TestThreeWayValve (sim) 0.717.951.002.280.590.010.184.9011.73
ThermoSysPro.Fluid.Examples.SimpleExamples.TestVolumeA (sim) 11.619.110.932.260.860.020.365.6044.49
ThermoSysPro.Fluid.Examples.SimpleExamples.TestVolumeI (sim) 9.408.790.922.260.800.020.195.5449.60
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_IF97 (sim) 21.378.710.932.330.570.020.195.61191.36
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test1_polynomial (sim) 0.038.720.932.250.580.020.185.6810.31
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_IF97 (sim) 1.088.420.932.420.530.010.175.2913.46
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test2_polynomial (sim) 0.038.210.932.240.540.010.175.249.79
ThermoSysPro.Properties.WaterSteamSimple.Validation.Bench.Test3_IF97 (sim) 3.238.990.942.250.660.020.195.8720.21
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_T (sim) 0.034.390.951.740.010.000.322.326.00
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_d (sim) 0.034.480.961.750.010.000.322.406.14
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_h (sim) 0.076.630.941.820.250.010.184.388.39
ThermoSysPro.Properties.WaterSteamSimple.Validation.calculette_p (sim) 0.076.680.941.850.260.010.194.388.42