Environment - simulationEnvironment: startTime=1.5552e+07 stopTime=1.5984e+07 tolerance=1e-06 numberOfIntervals=120 stepSize=3600 Regular simulation: ./Buildings_12_Buildings.Utilities.Plotters.Examples.SingleZoneVAV -abortSlowSimulation -alarm=400 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | info | Using sparse solver for linear system 10, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | Using sparse solver for linear system 22, | | | | because density of 0.160 remains under threshold of 0.200. LOG_STDOUT | info | The maximum density for using sparse solvers can be specified | | | | using the runtime flag '<-lssMaxDensity=value>'. LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Interfaces/PartialFourPortInterface.mo:23:3-24:84:writable] | | | | The following assertion has been violated at time 15668280.575854 | | | | ((hvac.cooCoi.m1_flow >= 0.0 and hvac.cooCoi.m1_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.m1_flow <= 1e5, has value: -1.26218e-29" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Interfaces/PartialTwoPortTransport.mo:34:3-36:69:writable] | | | | The following assertion has been violated at time 15705840.359068 | | | | ((hvac.ideVal.preMasFlo.m_flow >= 0.0 and hvac.ideVal.preMasFlo.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.ideVal.preMasFlo.m_flow <= 1e5, has value: -2.52435e-29" LOG_STATS | info | gbode (single-rate integration): esdirk4 LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.196117s reading init.xml | | | | | | 0.0129735s reading info.xml | | | | | | 0.00450932s [ 0.0%] pre-initialization | | | | | | 0.0359056s [ 0.2%] initialization | | | | | | 0.0187274s [ 0.1%] steps | | | | | | 0s [ 0.0%] solver (excl. callbacks) | | | | | | 0.0141217s [ 0.1%] creating output-file | | | | | | 0.0489296s [ 0.2%] event-handling | | | | | | 0.00882608s [ 0.0%] overhead | | | | | | 19.8521s [ 99.3%] simulation | | | | | | 19.9831s [100.0%] total | | | | | events | | | | | | 80 state events | | | | | | 561 time events | | | | | solver: gbode | | | | | | 17414 steps taken | | | | | | 665991 calls of functionODE | | | | | | 2842 evaluations of jacobian | | | | | | 801 error test failures | | | | | | 0 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. LOG_STDOUT | info | Wrote plot file "/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelicaLibraryTesting/Buildings_12_Buildings.Utilities.Plotters.Examples.SingleZoneVAV/plots.html".