Environment - simulationEnvironment: startTime=0 stopTime=172800 tolerance=1e-06 numberOfIntervals=2500 stepSize=69.12 Regular simulation: ./Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Validation.Schedule.EquipmentScheduleOutputVariable -abortSlowSimulation -alarm=400 -s gbode -emit_protected -lv LOG_STATS LOG_STDOUT | warning | Numerical Jacobians without coloring are currently not supported by GBODE. Colored numerical Jacobian will be used. EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2025.12.03 13:43 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Starting Simulation at 01/01/2006 for SPAWN-RUNPERIOD LOG_STDOUT | info | Output EquipmentScheduleOutputVariable.equEle.y has in Modelica the unit 1. LOG_ASSERT | warning | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Interfaces/PartialTwoPortInterface.mo:20:3-21:81:writable] | | | | The following assertion has been violated at time 0.000000 | | | | ((duc.m_flow >= 0.0 and duc.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= duc.m_flow <= 1e5, has value: -6.59347e-15" LOG_SUCCESS | info | The initialization finished successfully without homotopy method. LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Utilities/Diagnostics/AssertEquality.mo:6:5-11:47:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true)) --> "EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Utilities/Diagnostics/AssertEquality.mo:6:5-11:47:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true)) --> "EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06" LOG_ASSERT | info | Found event, previous asserts are ignored. LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Utilities/Diagnostics/AssertEquality.mo:6:5-11:47:writable] | | | | The following assertion has been violated at time 25200.000003 | | | | ((if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true)) --> "EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06" LOG_ASSERT | error | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Utilities/Diagnostics/AssertEquality.mo:6:5-11:47:writable] | | | | The following assertion has been violated at time 25200.000000 | | | | ((if noEvent(time > assEqu.t0) then noEvent(abs(equEle.y - assEqu.u2) < assEqu.threShold) else true)) --> "EnergyPlus did not synchronize the output variable correctly | | | | time = 25200 | | | | u1 = 0 | | | | u2 = 500 | | | | abs(u1-u2) = 500 | | | | threShold = 1e-06" Writing tabular output file results using HTML format. EnergyPlus Run Time=00hr 00min 0.32sec EnergyPlus Completed Successfully.