Environment - simulationEnvironment: startTime=1.6848e+07 stopTime=1.728e+07 tolerance=1e-07 numberOfIntervals=10133 stepSize=42.633 Regular simulation: ./Buildings_12_Buildings.ThermalZones.EnergyPlus_24_2_0.Examples.SmallOffice.Guideline36Summer -abortSlowSimulation -alarm=400 -s cvode -emit_protected -lv LOG_STATS EnergyPlus Starting EnergyPlus, Version 24.2.0-9f1b36b00b, YMD=2025.12.03 06:21 Adjusting Air System Sizing Adjusting Standard 62.1 Ventilation Sizing Initializing Simulation Reporting Surfaces Beginning Primary Simulation Initializing New Environment Parameters Warming up {1} Warming up {2} Warming up {3} Warming up {4} Warming up {5} Warming up {6} Warming up {7} Warming up {8} Warming up {9} Warming up {10} Warming up {11} Starting Simulation at 07/15/2006 for SPAWN-RUNPERIOD LOG_SUCCESS | info | The initialization finished successfully with 3 homotopy steps. LOG_ASSERT | debug | ##CVODE## Desired step to small! LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16848042.632981 | | | | ((hvac.fanSup.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.heaDis.etaHyd, has value: -0.000271564" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16848042.632981 | | | | ((hvac.fanSup.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.etaHyd, has value: -1.1016e-08" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Sensors/VolumeFlowRate.mo:19:3-25:24:writable] | | | | The following assertion has been violated at time 16848120.000000 | | | | ((hvac.VOut1.V_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VOut1.V_flow, has value: -1.31349e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16848120.000169 | | | | ((hvac.fanSup.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.fanSup.eff.yMot, has value: -2.42634e-88" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16850302.180993 | | | | ((hvac.pumCooCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.eff.yMot, has value: -3.26802e-87" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/FlowMachineInterface.mo:311:3-315:28:writable] | | | | The following assertion has been violated at time 16851709.069377 | | | | ((hvac.pumHeaCoi.eff.yMot >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumHeaCoi.eff.yMot, has value: -5.04756e-115" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16870540.284829 | | | | ((hvac.conVAV[2].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16870540.284829 | | | | ((hvac.conVAV[2].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16901895.765026 | | | | ((hvac.conVAV[1].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PowerInterface.mo:46:3-47:27:writable] | | | | The following assertion has been violated at time 16916468.568045 | | | | ((hvac.pumCooCoi.heaDis.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.heaDis.etaHyd, has value: -9.52371e-22" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:117:3-118:81:writable] | | | | The following assertion has been violated at time 16916468.568045 | | | | ((hvac.pumCooCoi.m_flow >= 0.0 and hvac.pumCooCoi.m_flow <= 1e5)) --> "Variable violating min/max constraint: 0.0 <= hvac.pumCooCoi.m_flow <= 1e5, has value: -9.65891e-12" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/Movers/BaseClasses/PartialFlowMachine.mo:101:3-101:89:writable] | | | | The following assertion has been violated at time 16916468.568045 | | | | ((hvac.pumCooCoi.etaHyd >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.pumCooCoi.etaHyd, has value: -6.591e-24" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Fluid/HeatExchangers/WetCoilEffectivenessNTU.mo:68:3-73:35:writable] | | | | The following assertion has been violated at time 16916468.568045 | | | | ((hvac.cooCoi.SHR >= 0.0 and hvac.cooCoi.SHR <= 1.0)) --> "Variable violating min/max constraint: 0.0 <= hvac.cooCoi.SHR <= 1.0, has value: -1.74243e-25" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16941579.394059 | | | | ((hvac.VAVBox[5].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[5].VSup_flow, has value: -1.18246e-15" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16941579.394059 | | | | ((hvac.VAVBox[4].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[4].VSup_flow, has value: -7.97617e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16941579.394059 | | | | ((hvac.VAVBox[3].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[3].VSup_flow, has value: -8.9638e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16941579.394059 | | | | ((hvac.VAVBox[2].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[2].VSup_flow, has value: -7.97617e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Examples/VAVReheat/BaseClasses/VAVReheatBox.mo:70:3-74:57:writable] | | | | The following assertion has been violated at time 16941579.394059 | | | | ((hvac.VAVBox[1].VSup_flow >= 0.0)) --> "Variable violating min constraint: 0.0 <= hvac.VAVBox[1].VSup_flow, has value: -8.9638e-16" LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956114.422495 | | | | ((hvac.conVAV[4].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956132.061258 | | | | ((hvac.conVAV[3].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000339 | | | | ((hvac.conVAV[1].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000339 | | | | ((hvac.conVAV[4].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000339 | | | | ((hvac.conVAV[5].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 16956300.000339 | | | | ((hvac.conVAV[5].ala.not2.y)) --> "Warning: airflow is less than 70% of the setpoint." LOG_ASSERT | info | [/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 12.1.1-maint.12.x/Controls/OBC/CDL/Utilities/Assert.mo:11:3-11:45:writable] | | | | The following assertion has been violated at time 17047387.113783 | | | | ((hvac.conVAV[3].ala.not1.y)) --> "Warning: airflow is less than 50% of the setpoint." LOG_STATS | info | ### STATISTICS ### | | | | | timer | | | | | | 0.327213s reading init.xml | | | | | | 0.0235472s reading info.xml | | | | | | 0.00768326s [ 0.0%] pre-initialization | | | | | | 7.31435s [ 9.1%] initialization | | | | | | 0.00106782s [ 0.0%] steps | | | | | | 2.63007s [ 3.3%] solver (excl. callbacks) | | | | | | 0.547569s [ 0.7%] creating output-file | | | | | | 3.59057s [ 4.5%] event-handling | | | | | | 0.287111s [ 0.4%] overhead | | | | | | 66.1641s [ 82.1%] simulation | | | | | | 80.5425s [100.0%] total | | | | | events | | | | | | 1980 state events | | | | | | 3601 time events | | | | | solver: cvode | | | | | | 71355 steps taken | | | | | | 113450 calls of functionODE | | | | | | 6085 evaluations of jacobian | | | | | | 2782 error test failures | | | | | | 142 convergence test failures | | | | | | 0s time of jacobian evaluation LOG_SUCCESS | info | The simulation finished successfully. Writing final SQL reports EnergyPlus Run Time=00hr 01min 13.71sec EnergyPlus Completed Successfully.