Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo) Running command: translateModel(TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer") translateModel(TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo): time 2.265/2.265, allocations: 389.5 MB / 409.2 MB, free: 12.7 MB / 318.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0006346/0.0006346, allocations: 39.88 kB / 0.4892 GB, free: 4.797 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 0.7188/0.7189, allocations: 127.2 MB / 0.7029 GB, free: 5.559 MB / 0.4981 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.09376/0.09376, allocations: 22.37 MB / 0.8396 GB, free: 16.48 MB / 0.5294 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01264/0.01264, allocations: 0.8871 MB / 0.9615 GB, free: 3.434 MB / 0.6388 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.2618/0.2618, allocations: 45.04 MB / 1.127 GB, free: 97.87 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.1016/0.1016, allocations: 13.56 MB / 1.27 GB, free: 93.58 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00124/0.00124, allocations: 111.4 kB / 1.403 GB, free: 7.207 MB / 0.7013 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001432/0.001432, allocations: 192.1 kB / 1.536 GB, free: 222.8 MB / 0.8263 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.735/1.735, allocations: 222.9 MB / 1.887 GB, free: 91.93 MB / 0.8888 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0005879/0.0005879, allocations: 31.94 kB / 2.068 GB, free: 15.18 MB / 0.92 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0005847/0.0005847, allocations: 23.97 kB / 2.249 GB, free: 5.387 MB / 1.092 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.098/1.098, allocations: 220.8 MB / 2.646 GB, free: 132.2 MB / 1.123 GB Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.1 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, "1.8.1") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.2 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.005493/0.005493, allocations: 311.5 kB / 3.119 GB, free: 9.75 MB / 1.233 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.641/2.646, allocations: 229.5 MB / 3.343 GB, free: 6.008 MB / 1.405 GB Notification: Performance of NFInst.instantiate(TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer): time 0.01568/2.662, allocations: 11.06 MB / 3.354 GB, free: 14.1 MB / 1.42 GB Notification: Performance of NFInst.instExpressions: time 0.01503/2.677, allocations: 7.185 MB / 3.361 GB, free: 8.66 MB / 1.42 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.00288/2.68, allocations: 29.69 kB / 3.361 GB, free: 8.652 MB / 1.42 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.004641/2.685, allocations: 1.18 MB / 3.362 GB, free: 7.906 MB / 1.42 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeBindings: time 0.006523/2.691, allocations: 1.215 MB / 3.363 GB, free: 6.996 MB / 1.42 GB Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Notification: Performance of NFTyping.typeClassSections: time 0.002092/2.693, allocations: 0.4927 MB / 3.364 GB, free: 6.609 MB / 1.42 GB Notification: Performance of NFFlatten.flatten: time 0.005112/2.698, allocations: 2.527 MB / 3.366 GB, free: 5.078 MB / 1.42 GB Notification: Performance of NFFlatten.resolveConnections: time 0.001208/2.7, allocations: 0.5534 MB / 3.367 GB, free: 4.789 MB / 1.42 GB Notification: Performance of NFEvalConstants.evaluate: time 0.003244/2.703, allocations: 1.328 MB / 3.368 GB, free: 4.121 MB / 1.42 GB Notification: Performance of NFSimplifyModel.simplify: time 0.002591/2.705, allocations: 1.369 MB / 3.369 GB, free: 3.258 MB / 1.42 GB Notification: Performance of NFPackage.collectConstants: time 0.0006287/2.706, allocations: 234.3 kB / 3.369 GB, free: 3.258 MB / 1.42 GB Notification: Performance of NFFlatten.collectFunctions: time 0.001508/2.708, allocations: 0.5128 MB / 3.37 GB, free: 3.098 MB / 1.42 GB Notification: Performance of NFScalarize.scalarize: time 0.00114/2.709, allocations: 1.095 MB / 3.371 GB, free: 2.371 MB / 1.42 GB Notification: Performance of NFVerifyModel.verify: time 0.001862/2.711, allocations: 1.658 MB / 3.373 GB, free: 1.117 MB / 1.42 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:79:53-79:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:83:53-83:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:42:70-42:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:71-105:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.05159/2.762, allocations: 24.06 MB / 3.396 GB, free: 7.488 MB / 1.436 GB Notification: Performance of FrontEnd - DAE generated: time 1.025e-05/2.762, allocations: 5.094 kB / 3.396 GB, free: 7.484 MB / 1.436 GB Notification: Performance of FrontEnd: time 2.425e-06/2.762, allocations: 3.938 kB / 3.396 GB, free: 7.48 MB / 1.436 GB Notification: Performance of Transformations before backend: time 0.0001497/2.762, allocations: 3.938 kB / 3.396 GB, free: 7.477 MB / 1.436 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 388 * Number of variables: 388 Notification: Performance of Generate backend data structure: time 0.01119/2.774, allocations: 4.334 MB / 3.4 GB, free: 4.352 MB / 1.436 GB Notification: Performance of prepare preOptimizeDAE: time 5.334e-05/2.774, allocations: 10.12 kB / 3.4 GB, free: 4.352 MB / 1.436 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.001599/2.775, allocations: 438.9 kB / 3.401 GB, free: 4.121 MB / 1.436 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.00917/2.784, allocations: 3.561 MB / 3.404 GB, free: 1.684 MB / 1.436 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.0002085/2.785, allocations: 151 kB / 3.404 GB, free: 1.59 MB / 1.436 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.0002299/2.785, allocations: 147 kB / 3.405 GB, free: 1.543 MB / 1.436 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.0035/2.789, allocations: 1.931 MB / 3.406 GB, free: 168 kB / 1.436 GB Notification: Performance of preOpt findStateOrder (simulation): time 4.039e-05/2.789, allocations: 7.875 kB / 3.406 GB, free: 164 kB / 1.436 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.0001467/2.789, allocations: 64.56 kB / 3.407 GB, free: 116 kB / 1.436 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 4.55e-05/2.789, allocations: 40.78 kB / 3.407 GB, free: 116 kB / 1.436 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.002996/2.792, allocations: 1.593 MB / 3.408 GB, free: 15.29 MB / 1.452 GB Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.01494/2.807, allocations: 8.235 MB / 3.416 GB, free: 8.23 MB / 1.452 GB Notification: Performance of preOpt comSubExp (simulation): time 0.00105/2.808, allocations: 410.6 kB / 3.417 GB, free: 7.895 MB / 1.452 GB Notification: Performance of preOpt resolveLoops (simulation): time 0.0003268/2.808, allocations: 143.4 kB / 3.417 GB, free: 7.797 MB / 1.452 GB Notification: Performance of preOpt evalFunc (simulation): time 0.0001936/2.808, allocations: 96.59 kB / 3.417 GB, free: 7.695 MB / 1.452 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.0005409/2.809, allocations: 264 kB / 3.417 GB, free: 7.469 MB / 1.452 GB Notification: Performance of pre-optimization done (n=30): time 2.615e-06/2.809, allocations: 3.938 kB / 3.417 GB, free: 7.465 MB / 1.452 GB Notification: Performance of matching and sorting (n=30): time 0.002326/2.811, allocations: 0.7753 MB / 3.418 GB, free: 7.047 MB / 1.452 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.0001741/2.811, allocations: 301.1 kB / 3.418 GB, free: 6.691 MB / 1.452 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.006858/2.818, allocations: 3.995 MB / 3.422 GB, free: 4.648 MB / 1.452 GB Notification: Performance of collectPreVariables (initialization): time 7.781e-05/2.818, allocations: 32.23 kB / 3.422 GB, free: 4.613 MB / 1.452 GB Notification: Performance of collectInitialEqns (initialization): time 0.00185/2.82, allocations: 1.916 MB / 3.424 GB, free: 2.922 MB / 1.452 GB Notification: Performance of collectInitialBindings (initialization): time 0.0001736/2.82, allocations: 131.4 kB / 3.424 GB, free: 2.816 MB / 1.452 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.000682/2.821, allocations: 489.9 kB / 3.424 GB, free: 2.523 MB / 1.452 GB Notification: Performance of setup shared object (initialization): time 0.0001238/2.821, allocations: 302.4 kB / 3.425 GB, free: 2.227 MB / 1.452 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.001089/2.822, allocations: 0.5778 MB / 3.425 GB, free: 1.941 MB / 1.452 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.00216/2.825, allocations: 1.887 MB / 3.427 GB, free: 15.8 MB / 1.467 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: load.collectElectricPower.E = $START.load.collectElectricPower.E (0.0 = $START.load.collectElectricPower.E) Notification: Performance of analyzeInitialSystem (initialization): time 0.008131/2.833, allocations: 8.364 MB / 3.435 GB, free: 6.742 MB / 1.467 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 5.231e-05/2.833, allocations: 13 kB / 3.435 GB, free: 6.742 MB / 1.467 GB Notification: Performance of matching and sorting (n=244) (initialization): time 0.004956/2.838, allocations: 2.156 MB / 3.437 GB, free: 5.637 MB / 1.467 GB Notification: Performance of prepare postOptimizeDAE: time 5.348e-05/2.838, allocations: 25.97 kB / 3.437 GB, free: 5.637 MB / 1.467 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 6.496e-05/2.838, allocations: 46.12 kB / 3.438 GB, free: 5.637 MB / 1.467 GB Notification: Performance of postOpt tearingSystem (initialization): time 9.161e-05/2.838, allocations: 61.72 kB / 3.438 GB, free: 5.637 MB / 1.467 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.001274/2.839, allocations: 469.4 kB / 3.438 GB, free: 5.52 MB / 1.467 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.0001018/2.839, allocations: 94.11 kB / 3.438 GB, free: 5.449 MB / 1.467 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.002719/2.842, allocations: 273.2 kB / 3.438 GB, free: 5.18 MB / 1.467 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.0001702/2.842, allocations: 120 kB / 3.438 GB, free: 5.062 MB / 1.467 GB Warning: The initial conditions are over specified. The following 63 initial equations are redundant, so they are removed from the initialization system: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg load.collectElectricPower.E = $START.load.collectElectricPower.E. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 212 * Number of states: 0 () * Number of discrete variables: 10 ($PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (244): * Single equations (assignments): 244 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 Notification: Performance of prepare postOptimizeDAE: time 0.002516/2.845, allocations: 1.496 MB / 3.44 GB, free: 3.484 MB / 1.467 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.001033/2.846, allocations: 371.1 kB / 3.44 GB, free: 3.117 MB / 1.467 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.001647/2.847, allocations: 498.4 kB / 3.441 GB, free: 2.621 MB / 1.467 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 1.374e-05/2.848, allocations: 7.938 kB / 3.441 GB, free: 2.613 MB / 1.467 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 1.159e-05/2.848, allocations: 8 kB / 3.441 GB, free: 2.605 MB / 1.467 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 8.486e-06/2.848, allocations: 0 / 3.441 GB, free: 2.605 MB / 1.467 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.006027/2.854, allocations: 2.008 MB / 3.443 GB, free: 0.5352 MB / 1.467 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 1.077e-05/2.854, allocations: 4 kB / 3.443 GB, free: 0.5312 MB / 1.467 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.000265/2.854, allocations: 63.83 kB / 3.443 GB, free: 480 kB / 1.467 GB Notification: Performance of postOpt tearingSystem (simulation): time 1.103e-05/2.854, allocations: 8.047 kB / 3.443 GB, free: 472 kB / 1.467 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 3.589e-05/2.854, allocations: 11.98 kB / 3.443 GB, free: 460 kB / 1.467 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 1.126e-05/2.854, allocations: 11.94 kB / 3.443 GB, free: 448 kB / 1.467 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 5.861e-06/2.854, allocations: 4 kB / 3.443 GB, free: 444 kB / 1.467 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.001737/2.856, allocations: 0.8209 MB / 3.444 GB, free: 15.56 MB / 1.483 GB Notification: Performance of postOpt removeConstants (simulation): time 0.001719/2.857, allocations: 0.6014 MB / 3.444 GB, free: 14.94 MB / 1.483 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.0007811/2.858, allocations: 12 kB / 3.444 GB, free: 14.93 MB / 1.483 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.00112/2.859, allocations: 19.97 kB / 3.444 GB, free: 14.91 MB / 1.483 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 9.645e-05/2.859, allocations: 27.97 kB / 3.444 GB, free: 14.88 MB / 1.483 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 4.599e-05/2.86, allocations: 12 kB / 3.444 GB, free: 14.87 MB / 1.483 GB Notification: Performance of sorting global known variables: time 0.005471/2.865, allocations: 2.651 MB / 3.447 GB, free: 12.22 MB / 1.483 GB Notification: Performance of sort global known variables: time 1.4e-07/2.865, allocations: 0 / 3.447 GB, free: 12.22 MB / 1.483 GB Notification: Performance of remove unused functions: time 0.003043/2.868, allocations: 0.5344 MB / 3.447 GB, free: 11.69 MB / 1.483 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 10 * Number of states: 0 () * Number of discrete variables: 6 ($whenCondition1,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition2,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled) * Number of discrete states: 4 (simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (30): * Single equations (assignments): 26 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 0 * When equations: 4 * If-equations: 0 * Equation systems (not torn): 0 * Torn equation systems: 0 * Mixed (continuous/discrete) equation systems: 0 [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.002233/2.87, allocations: 0.88 MB / 3.448 GB, free: 11.1 MB / 1.483 GB Notification: Performance of simCode: created initialization part: time 0.002816/2.873, allocations: 1.147 MB / 3.449 GB, free: 9.965 MB / 1.483 GB Notification: Performance of simCode: created event and clocks part: time 4.017e-06/2.873, allocations: 4 kB / 3.449 GB, free: 9.961 MB / 1.483 GB Notification: Performance of simCode: created simulation system equations: time 0.0004185/2.874, allocations: 151.7 kB / 3.45 GB, free: 9.812 MB / 1.483 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.002993/2.877, allocations: 368.9 kB / 3.45 GB, free: 9.457 MB / 1.483 GB Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.01213/2.889, allocations: 5.464 MB / 3.455 GB, free: 3.93 MB / 1.483 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.003273/2.892, allocations: 2.091 MB / 3.457 GB, free: 1.805 MB / 1.483 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.000746/2.893, allocations: 219.3 kB / 3.457 GB, free: 1.59 MB / 1.483 GB Notification: Performance of SimCode: time 8.41e-07/2.893, allocations: 0 / 3.457 GB, free: 1.59 MB / 1.483 GB Notification: Performance of Templates: time 0.0576/2.95, allocations: 32.94 MB / 3.49 GB, free: 0.7578 MB / 1.514 GB make -j1 -f TransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer.makefile make -j1 -f TransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumer.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerCalcHelperMain.o OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerCalcHelperMain.cpp In file included from OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerCalcHelperMain.cpp:28: ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:544:25: error: no matching function for call to 'TILMedia_createExternalObject' externalObject__ext = TILMedia_createExternalObject(objectType_.c_str(), mediumName_.c_str(), flags__ext, ConstArray(xi_).getData(), nc__ext, condensingIndex__ext, instanceName_.c_str()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:32:7: note: candidate function not viable: 4th argument ('const double *') would lose const qualifier void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:613:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:639:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:665:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:691:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:717:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:743:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ 7 errors generated. make: *** [: OMCppTransiEnt_TransiEnt.Consumer.Electrical.Check.CheckAverageLoadConsumerCalcHelperMain.o] Error 1