Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr TransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo", uses=false) Using package TransiEnt with version 2.0.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo) Using package DataFiles with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo) Using package Design with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Using package Modelica_StateGraph2 with version 2.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo) Using package Modelica_LinearSystems2 with version 2.4.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo) Using package ModelicaReference with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo) Using package TILMedia with version 1.8.1 ClaRa (/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo) Using package ClaRa with version 1.8.1 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo) Using package DymolaCommands with version 0.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo) Using package Buildings with version 9.1.2 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo) Running command: translateModel(TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor") translateModel(TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="TransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Buildings 9.1.2/package.mo): time 2.266/2.266, allocations: 389.5 MB / 409.2 MB, free: 12.75 MB / 318.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DymolaCommands master/package.mo): time 0.0006772/0.0006772, allocations: 39.94 kB / 0.4891 GB, free: 4.797 MB / 398.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestReheater, which is expected to be stored in file TestReheater.mo, but seems to be named testReheater.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Control/PredictorModels_3508/Check/testReheater.mo:2:1-117:17:writable] Warning: Expected the package to have name testReheater, but got TestReheater. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/package.mo:2:1-23:10:writable] Warning: PhysicalMills was referenced in the package.order file, but was not found in package.mo, PhysicalMills/package.mo or PhysicalMills.mo. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: Expected the package to have name physicalMills, but got PhysicalMills. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4_advancedInit, which is expected to be stored in file Mill_L4_advancedInit.mo, but seems to be named mill_L4_advancedInit.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/package.mo:2:1-22:18:writable] Warning: The package.order file contains a class Mill_L4, which is expected to be stored in file Mill_L4.mo, but seems to be named mill_L4.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have name mill_L4_advancedInit, but got Mill_L4_advancedInit. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4_advancedInit.mo:2:1-58:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have name mill_L4, but got Mill_L4. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/mill_L4.mo:2:1-315:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_2, which is expected to be stored in file TestMillBox_2.mo, but seems to be named testMillBox_2.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1_measurementInput, which is expected to be stored in file TestMillBox_1_measurementInput.mo, but seems to be named testMillBox_1_measurementInput.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/package.mo:2:1-21:10:writable] Warning: The package.order file contains a class TestMillBox_1, which is expected to be stored in file TestMillBox_1.mo, but seems to be named testMillBox_1.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have name testMillBox_2, but got TestMillBox_2. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_2.mo:2:1-297:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have name testMillBox_1_measurementInput, but got TestMillBox_1_measurementInput. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1_measurementInput.mo:2:1-1342:35:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have name testMillBox_1, but got TestMillBox_1. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Check/testMillBox_1.mo:2:1-465:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Check; but got within ClaRa.Components.Mills.PhysicalMills.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/package.mo:2:1-29:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills; but got within ClaRa.Components.Mills.PhysicalMills; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FlowClassifier.mo:2:1-346:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/CentrifugalClassifier.mo:2:1-380:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/GrinderRingRoller.mo:2:1-294:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/FuelJoin_distributed.mo:2:1-133:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Dryer.mo:2:1-301:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/package.mo:2:1-20:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/package.mo:2:1-20:13:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_complex.mo:2:1-71:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_constant.mo:2:1-49:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Transport_Velocity/Transport_base.mo:2:1-52:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Transport_Velocity; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/package.mo:2:1-20:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Kersting.mo:2:1-80:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_Steinmetz.mo:2:1-104:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_constant.mo:2:1-45:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Selection_Function/Selection_base.mo:2:1-50:19:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Selection_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Selection_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/package.mo:2:1-20:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Austin.mo:2:1-109:20:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_Steinmetz.mo:2:1-106:23:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_constant.mo:2:1-45:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Grinding/Breakage_Function/Breakage_base.mo:2:1-51:18:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Grinding.Breakage_Function; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/package.mo:2:1-20:11:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_ideal.mo:2:1-58:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Drying/Drying_base.mo:2:1-44:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Drying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Drying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/package.mo:2:1-20:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow.mo:2:1-111:21:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal.mo:2:1-153:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_centrifugal_base.mo:2:1-45:33:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Classifying/Classifying_flow_base.mo:2:1-45:26:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Classifying; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Classifying; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/package.mo:2:1-20:12:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Dryer.mo:2:1-57:15:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_FlowClassifier.mo:2:1-67:24:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_CentrifugalClassifier.mo:2:1-69:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/iCom_Grinder.mo:2:1-61:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_21classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/GeometricProgression.mo:2:1-56:25:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_generic.mo:2:1-43:31:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_05classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_example_11classes.mo:2:1-43:41:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Fundamentals/Records/FuelClassification_base.mo:2:1-61:28:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Fundamentals.Records; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Fundamentals.Records; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes; but got within ClaRa.Components.Mills.PhysicalMills.Volumes; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestFuelJoin, which is expected to be stored in file TestFuelJoin.mo, but seems to be named testFuelJoin.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestAerosolVolume, which is expected to be stored in file TestAerosolVolume.mo, but seems to be named testAerosolVolume.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestDryer, which is expected to be stored in file TestDryer.mo, but seems to be named testDryer.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/package.mo:2:1-23:10:writable] Warning: The package.order file contains a class TestGrinder, which is expected to be stored in file TestGrinder.mo, but seems to be named testGrinder.mo. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have name testFuelJoin, but got TestFuelJoin. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testFuelJoin.mo:2:1-93:17:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have name testAerosolVolume, but got TestAerosolVolume. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testAerosolVolume.mo:2:1-176:22:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have name testDryer, but got TestDryer. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testDryer.mo:2:1-93:14:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have name testGrinder, but got TestGrinder. Proceeding since only the case of the names are different. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/Components/Mills/physicalMills/Volumes/Check/testGrinder.mo:2:1-154:16:writable] Warning: Expected the package to have within ClaRa.Components.Mills.physicalMills.Volumes.Check; but got within ClaRa.Components.Mills.PhysicalMills.Volumes.Check; (ignoring the potential error; the class might have been inserted at an unexpected location). Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/package.mo): time 0.7323/0.7323, allocations: 127.2 MB / 0.7029 GB, free: 5.559 MB / 0.4981 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/package.mo): time 0.09438/0.09438, allocations: 22.37 MB / 0.8396 GB, free: 16.44 MB / 0.5294 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaReference 4.0.0+maint.om/package.mo): time 0.01418/0.01418, allocations: 0.8876 MB / 0.9615 GB, free: 3.387 MB / 0.6388 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_LinearSystems2 2.4.0/package.mo): time 0.2751/0.2751, allocations: 45.03 MB / 1.127 GB, free: 97.82 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica_StateGraph2 2.1.0/package.mo): time 0.1061/0.1061, allocations: 13.56 MB / 1.27 GB, free: 93.54 MB / 0.6544 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001811/0.001811, allocations: 115 kB / 1.403 GB, free: 7.164 MB / 0.7013 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001361/0.001361, allocations: 189.9 kB / 1.536 GB, free: 222.8 MB / 0.8263 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.795/1.795, allocations: 222.9 MB / 1.887 GB, free: 91.59 MB / 0.8888 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Design master/package.mo): time 0.0006677/0.0006676, allocations: 39.88 kB / 2.068 GB, free: 15.08 MB / 0.92 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/DataFiles master/package.mo): time 0.0007086/0.0007085, allocations: 27.94 kB / 2.249 GB, free: 5.277 MB / 1.092 GB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/package.mo): time 1.097/1.097, allocations: 220.8 MB / 2.646 GB, free: 132.1 MB / 1.123 GB Warning: Requested package TILMedia of version 1.8.0 ClaRa, but this package was already loaded with version 1.8.1 ClaRa. OpenModelica cannot reason about compatibility between the two packages since they are not semantic versions. Warning: TransiEnt requested package ClaRa of version 1.8.0. ClaRa 1.8.1 is used instead which states that it is only compatible with a conversion script. Use convertPackageToLibrary(TransiEnt, ClaRa, "1.8.1") to run the conversion script or proceed with potential issues as a result. Notification: TransiEnt requested package Buildings of version 9.0.0. Buildings 9.1.2 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.005396/0.005396, allocations: 307.5 kB / 3.119 GB, free: 9.703 MB / 1.233 GB Notification: Performance of FrontEnd - Absyn->SCode: time 2.843/2.849, allocations: 229.5 MB / 3.343 GB, free: 5.996 MB / 1.405 GB Notification: Performance of NFInst.instantiate(TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor): time 0.08789/2.937, allocations: 78.19 MB / 3.419 GB, free: 8.664 MB / 1.467 GB Notification: Performance of NFInst.instExpressions: time 0.09399/3.031, allocations: 36.82 MB / 3.455 GB, free: 10.12 MB / 1.499 GB Notification: Performance of NFInst.updateImplicitVariability: time 0.03139/3.062, allocations: 362 kB / 3.456 GB, free: 10.02 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/ClaRa 1.8.1-ClaRa_1.8.1_Release/SimCenter.mo:69:5-70:35:writable] Warning: Connector cycleSumPort is not balanced: The number of potential variables (0) is not equal to the number of flow variables (4). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:85:3-85:105:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:86:3-86:112:writable] Warning: Connector primBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:87:3-87:102:writable] Warning: Connector primBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:88:3-88:111:writable] Warning: Connector secBalPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:89:3-89:101:writable] Warning: Connector secBalPowerOfferCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:90:3-90:92:writable] Warning: Connector surroundingGridLoad is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:92:3-92:126:writable] Warning: Connector tielinePowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:93:3-93:130:writable] Warning: Connector tielineSetPowerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:95:3-95:95:writable] Warning: Connector kineticEnergyCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:98:3-98:99:writable] Warning: Connector gwpCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:100:3-100:107:writable] Warning: Connector gwpCollectorHeat is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:103:3-103:82:writable] Warning: Connector heatFlowCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:3-105:87:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/CollectElectricPower.mo:67:3-67:137:writable] Warning: Connector powerCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (1). [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/LocalCollectors/PartialCollectCosts.mo:122:3-122:137:writable] Warning: Connector costsCollector is not balanced: The number of potential variables (0) is not equal to the number of flow variables (6). Notification: Performance of NFTyping.typeComponents: time 0.0245/3.087, allocations: 6.984 MB / 3.462 GB, free: 4.992 MB / 1.499 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:142:7-142:36:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:140:7-140:36:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:145:7-145:40:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:151:7-151:37:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:149:7-149:37:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:154:7-154:41:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:165:7-165:33:writable] Warning: Conditional component 'heat' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:166:7-166:23:writable] Warning: Conditional component 'heat' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/fullPathName.mo:2:1-78:17:writable] Warning: Pure function 'TransiEnt.Basics.Functions.fullPathName' contains a call to impure function 'Modelica.Utilities.Streams.print'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:524:13-528:28:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.specificEnthalpy_pTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.specificEnthalpy_pTxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_mflow.mo:186:7-186:33:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_mflow.mo:184:7-184:33:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_mflow.mo:189:7-189:37:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_mflow.mo:195:7-195:36:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_mflow.mo:193:7-193:36:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_mflow.mo:198:7-198:40:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:142:7-142:36:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:140:7-140:36:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:145:7-145:40:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:151:7-151:37:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:149:7-149:37:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:154:7-154:41:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:165:7-165:33:writable] Warning: Conditional component 'heat' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Storage/Gas/UndergroundGasStorageHeatTransfer_L2.mo:166:7-166:23:writable] Warning: Conditional component 'heat' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:159:7-159:33:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:157:7-157:33:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:162:7-162:37:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:168:7-168:36:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:166:7-166:36:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:171:7-171:40:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:182:7-182:42:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:183:7-183:44:writable] Warning: Conditional component 'T' is used in a non-connect context. Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BrownCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.BlackCoal) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOnshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.WindOffshore) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Hydro) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Nuclear) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil as Integer: 9. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrier.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.NaturalGas) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.DistrictHeating) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Oil) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Electricity) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar as Integer: 7. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Solar) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass as Integer: 8. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Biomass) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others as Integer: 10. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfPrimaryEnergyCarrierHeat.Others) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Storage as Integer: 5. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Storage) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Conventional as Integer: 2. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Conventional) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Cogeneration as Integer: 3. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Cogeneration) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Renewable as Integer: 4. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Renewable) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Generic as Integer: 6. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Generic) instead! Warning: Allowing usage of enumeration expression: TransiEnt.Basics.Types.TypeOfResource.Consumer as Integer: 1. This is non-standard Modelica, use Integer(TransiEnt.Basics.Types.TypeOfResource.Consumer) instead! [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:159:7-159:33:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:157:7-157:33:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:162:7-162:37:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:168:7-168:36:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:166:7-166:36:writable] Warning: Conditional component 'x' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:171:7-171:40:writable] Warning: Conditional component 'rho' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:182:7-182:42:writable] Warning: Conditional component 'T' is used in a non-connect context. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Gas/Compressor/ValveAndCompressor_dp.mo:183:7-183:44:writable] Warning: Conditional component 'T' is used in a non-connect context. Notification: Performance of NFTyping.typeBindings: time 0.04696/3.134, allocations: 10.24 MB / 3.472 GB, free: 12.64 MB / 1.514 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/VLEFluidFunctions.mo:11:13-15:20:writable] Warning: Pure function 'TILMedia.Internals.VLEFluidConfigurations.FullyMixtureCompatible.VLEFluidFunctions.pressure_dTxi' contains a call to impure function 'TILMedia.Internals.VLEFluidFunctions.pressure_dTxi'. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Basics/Functions/GasProperties/verboseXi.mo:2:1-93:14:writable] Warning: Pure function 'TransiEnt.Basics.Functions.GasProperties.verboseXi' contains a call to impure function 'Modelica.Utilities.Streams.print'. Warning: Allowing usage of enumeration expression: valveAndCompressor_mflow.compressor.typeOfResource as Integer: CAST(Integer, valveAndCompressor_mflow.compressor.typeOfResource). This is non-standard Modelica, use Integer(valveAndCompressor_mflow.compressor.typeOfResource) instead! Warning: Allowing usage of enumeration expression: valveAndCompressor_dp.compressor.typeOfResource as Integer: CAST(Integer, valveAndCompressor_dp.compressor.typeOfResource). This is non-standard Modelica, use Integer(valveAndCompressor_dp.compressor.typeOfResource) instead! Warning: Allowing usage of enumeration expression: valveAndCompressor_dp1.compressor.typeOfResource as Integer: CAST(Integer, valveAndCompressor_dp1.compressor.typeOfResource). This is non-standard Modelica, use Integer(valveAndCompressor_dp1.compressor.typeOfResource) instead! Notification: Performance of NFTyping.typeClassSections: time 0.03074/3.164, allocations: 10.32 MB / 3.482 GB, free: 4.488 MB / 1.514 GB Notification: Performance of NFFlatten.flatten: time 0.06145/3.226, allocations: 29.78 MB / 3.512 GB, free: 13.05 MB / 1.545 GB Notification: Performance of NFFlatten.resolveConnections: time 0.03688/3.263, allocations: 16.66 MB / 3.528 GB, free: 12.27 MB / 1.561 GB Notification: Performance of NFEvalConstants.evaluate: time 0.03723/3.3, allocations: 13.42 MB / 3.541 GB, free: 14.81 MB / 1.577 GB Notification: Performance of NFSimplifyModel.simplify: time 0.03247/3.333, allocations: 17.15 MB / 3.558 GB, free: 13.6 MB / 1.592 GB Notification: Performance of NFPackage.collectConstants: time 0.01498/3.348, allocations: 4.234 MB / 3.562 GB, free: 9.367 MB / 1.592 GB Notification: Performance of NFFlatten.collectFunctions: time 0.02103/3.369, allocations: 5.466 MB / 3.567 GB, free: 3.906 MB / 1.592 GB Notification: Performance of NFScalarize.scalarize: time 0.02497/3.394, allocations: 15.99 MB / 3.583 GB, free: 3.875 MB / 1.608 GB Notification: Performance of NFVerifyModel.verify: time 0.04541/3.439, allocations: 20.85 MB / 3.603 GB, free: 14.92 MB / 1.639 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:79:53-79:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/GwpEmissionsStatistics.mo:83:53-83:84:writable] Error: Variable simCenter.expertMode not found in scope GwpEmissionsStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Components/Statistics/Collectors/GlobalCollectors/EconomicStatistics.mo:42:70-42:85:writable] Error: Variable True not found in scope EconomicStatistics. [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/ModelStatistics.mo:105:71-105:86:writable] Error: Variable True not found in scope ModelStatistics. Notification: Performance of NFConvertDAE.convert: time 0.139/3.578, allocations: 87.86 MB / 3.689 GB, free: 7.031 MB / 1.717 GB Notification: Performance of FrontEnd - DAE generated: time 1.293e-05/3.578, allocations: 4 kB / 3.689 GB, free: 7.027 MB / 1.717 GB Notification: Performance of FrontEnd: time 2.384e-06/3.578, allocations: 0 / 3.689 GB, free: 7.027 MB / 1.717 GB Notification: Performance of Transformations before backend: time 0.003078/3.581, allocations: 0 / 3.689 GB, free: 7.027 MB / 1.717 GB Notification: Model statistics after passing the front-end and creating the data structures used by the back-end: * Number of equations: 5430 * Number of variables: 5430 Notification: Performance of Generate backend data structure: time 0.1606/3.742, allocations: 41.27 MB / 3.729 GB, free: 13.5 MB / 1.764 GB Notification: Performance of prepare preOptimizeDAE: time 7.684e-05/3.742, allocations: 8.031 kB / 3.729 GB, free: 13.49 MB / 1.764 GB Notification: Performance of preOpt normalInlineFunction (simulation): time 0.02507/3.767, allocations: 4.023 MB / 3.733 GB, free: 9.418 MB / 1.764 GB Notification: Performance of preOpt evaluateParameters (simulation): time 0.1185/3.886, allocations: 44.56 MB / 3.777 GB, free: 12.63 MB / 1.811 GB Notification: Performance of preOpt simplifyIfEquations (simulation): time 0.001974/3.888, allocations: 1.103 MB / 3.778 GB, free: 11.5 MB / 1.811 GB Notification: Performance of preOpt expandDerOperator (simulation): time 0.01014/3.898, allocations: 1.285 MB / 3.779 GB, free: 10.22 MB / 1.811 GB Notification: Performance of preOpt clockPartitioning (simulation): time 0.09984/3.998, allocations: 41.39 MB / 3.819 GB, free: 11.7 MB / 1.858 GB Notification: Performance of preOpt findStateOrder (simulation): time 0.0009481/3.999, allocations: 142.6 kB / 3.82 GB, free: 11.56 MB / 1.858 GB Notification: Performance of preOpt replaceEdgeChange (simulation): time 0.01023/4.009, allocations: 0.7538 MB / 3.82 GB, free: 10.81 MB / 1.858 GB Notification: Performance of preOpt inlineArrayEqn (simulation): time 0.002743/4.012, allocations: 1.678 MB / 3.822 GB, free: 9.129 MB / 1.858 GB Notification: Performance of preOpt removeEqualRHS (simulation): time 0.08655/4.098, allocations: 38.76 MB / 3.86 GB, free: 2.34 MB / 1.889 GB Warning: The model contains alias variables with redundant start and/or conflicting nominal values. It is recommended to resolve the conflicts, because otherwise the system could be hard to solve. To print the conflicting alias sets and the chosen candidates please use -d=aliasConflicts. Notification: Performance of preOpt removeSimpleEquations (simulation): time 0.3244/4.423, allocations: 188.2 MB / 4.044 GB, free: 14.55 MB / 2.092 GB Notification: Performance of preOpt comSubExp (simulation): time 0.03304/4.456, allocations: 18.18 MB / 4.061 GB, free: 12.18 MB / 2.108 GB Notification: Performance of preOpt resolveLoops (simulation): time 1.427/5.883, allocations: 16.17 MB / 4.077 GB, free: 0.5908 GB / 2.108 GB Notification: Performance of preOpt evalFunc (simulation): time 0.07958/5.963, allocations: 36.34 MB / 4.113 GB, free: 0.5708 GB / 2.108 GB Notification: Performance of preOpt encapsulateWhenConditions (simulation): time 0.03133/5.994, allocations: 16.5 MB / 4.129 GB, free: 0.5638 GB / 2.108 GB Notification: Performance of pre-optimization done (n=2301): time 3.96e-05/5.994, allocations: 1.406 kB / 4.129 GB, free: 0.5638 GB / 2.108 GB Notification: Performance of matching and sorting (n=2330): time 0.5083/6.503, allocations: 245.6 MB / 4.369 GB, free: 378.6 MB / 2.108 GB Notification: Performance of inlineWhenForInitialization (initialization): time 0.000397/6.503, allocations: 1.301 MB / 4.37 GB, free: 377 MB / 2.108 GB Notification: Performance of selectInitializationVariablesDAE (initialization): time 0.07016/6.573, allocations: 29.78 MB / 4.399 GB, free: 347.5 MB / 2.108 GB Notification: Performance of collectPreVariables (initialization): time 0.004412/6.578, allocations: 173.7 kB / 4.399 GB, free: 347.3 MB / 2.108 GB Notification: Performance of collectInitialEqns (initialization): time 0.01984/6.598, allocations: 15.32 MB / 4.414 GB, free: 332 MB / 2.108 GB Notification: Performance of collectInitialBindings (initialization): time 0.01085/6.608, allocations: 7.619 MB / 4.421 GB, free: 324.4 MB / 2.108 GB Notification: Performance of simplifyInitialFunctions (initialization): time 0.0231/6.632, allocations: 4.662 MB / 4.426 GB, free: 319.7 MB / 2.108 GB Notification: Performance of setup shared object (initialization): time 5.805e-05/6.632, allocations: 305.1 kB / 4.426 GB, free: 319.4 MB / 2.108 GB Notification: Performance of preBalanceInitialSystem (initialization): time 0.02545/6.657, allocations: 15.7 MB / 4.442 GB, free: 303.7 MB / 2.108 GB Notification: Performance of partitionIndependentBlocks (initialization): time 0.03238/6.69, allocations: 24.45 MB / 4.466 GB, free: 275.6 MB / 2.108 GB Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.other_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.other_demand (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.other_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.other_revenue (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.H_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.H_demand (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.H_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.H_revenue (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.Q_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.Q_demand (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.Q_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.Q_revenue (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.W_el_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.W_el_demand (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.W_el_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.W_el_revenue (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.other_demand = $START.valveAndCompressor_dp.compressor.collectCosts.other_demand (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.other_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.other_revenue (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.H_demand = $START.valveAndCompressor_dp.compressor.collectCosts.H_demand (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.H_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.H_revenue (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.Q_demand = $START.valveAndCompressor_dp.compressor.collectCosts.Q_demand (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.Q_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.Q_revenue (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.W_el_demand = $START.valveAndCompressor_dp.compressor.collectCosts.W_el_demand (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.W_el_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.W_el_revenue (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.other_demand = $START.storage1.storage.collectCosts_Storage.other_demand (0.0 = $START.storage1.storage.collectCosts_Storage.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.other_revenue = $START.storage1.storage.collectCosts_Storage.other_revenue (0.0 = $START.storage1.storage.collectCosts_Storage.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.H_demand = $START.storage1.storage.collectCosts_Storage.H_demand (0.0 = $START.storage1.storage.collectCosts_Storage.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.H_revenue = $START.storage1.storage.collectCosts_Storage.H_revenue (0.0 = $START.storage1.storage.collectCosts_Storage.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.Q_demand = $START.storage1.storage.collectCosts_Storage.Q_demand (0.0 = $START.storage1.storage.collectCosts_Storage.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.Q_revenue = $START.storage1.storage.collectCosts_Storage.Q_revenue (0.0 = $START.storage1.storage.collectCosts_Storage.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.W_el_demand = $START.storage1.storage.collectCosts_Storage.W_el_demand (0.0 = $START.storage1.storage.collectCosts_Storage.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.W_el_revenue = $START.storage1.storage.collectCosts_Storage.W_el_revenue (0.0 = $START.storage1.storage.collectCosts_Storage.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.other_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.other_demand (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.other_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.other_revenue (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.H_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.H_demand (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.H_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.H_revenue (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.Q_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.Q_demand (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.Q_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.Q_revenue (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.W_el_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.W_el_demand (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.W_el_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.W_el_revenue (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.other_demand = $START.storage.storage.collectCosts_Storage.other_demand (0.0 = $START.storage.storage.collectCosts_Storage.other_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.other_revenue = $START.storage.storage.collectCosts_Storage.other_revenue (0.0 = $START.storage.storage.collectCosts_Storage.other_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.H_demand = $START.storage.storage.collectCosts_Storage.H_demand (0.0 = $START.storage.storage.collectCosts_Storage.H_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.H_revenue = $START.storage.storage.collectCosts_Storage.H_revenue (0.0 = $START.storage.storage.collectCosts_Storage.H_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.Q_demand = $START.storage.storage.collectCosts_Storage.Q_demand (0.0 = $START.storage.storage.collectCosts_Storage.Q_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.Q_revenue = $START.storage.storage.collectCosts_Storage.Q_revenue (0.0 = $START.storage.storage.collectCosts_Storage.Q_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.W_el_demand = $START.storage.storage.collectCosts_Storage.W_el_demand (0.0 = $START.storage.storage.collectCosts_Storage.W_el_demand) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.W_el_revenue = $START.storage.storage.collectCosts_Storage.W_el_revenue (0.0 = $START.storage.storage.collectCosts_Storage.W_el_revenue) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectElectricPower.E = $START.valveAndCompressor_dp1.compressor.collectElectricPower.E (0.0 = $START.valveAndCompressor_dp1.compressor.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] (0.0 = $START.modelStatistics.heatingPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] (0.0 = $START.modelStatistics.heatingPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] (0.0 = $START.modelStatistics.heatingPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] (0.0 = $START.modelStatistics.heatingPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] (0.0 = $START.modelStatistics.heatingPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] (0.0 = $START.modelStatistics.heatingPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] (0.0 = $START.modelStatistics.electricPower.negPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] (0.0 = $START.modelStatistics.electricPower.negPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] (0.0 = $START.modelStatistics.electricPower.negPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] (0.0 = $START.modelStatistics.electricPower.negPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] (0.0 = $START.modelStatistics.electricPower.negPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] (0.0 = $START.modelStatistics.electricPower.negPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] (0.0 = $START.modelStatistics.electricPower.posPBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] (0.0 = $START.modelStatistics.electricPower.posPBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] (0.0 = $START.modelStatistics.electricPower.posPBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] (0.0 = $START.modelStatistics.electricPower.posPBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] (0.0 = $START.modelStatistics.electricPower.posPBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] (0.0 = $START.modelStatistics.electricPower.posPBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] (0.0 = $START.modelStatistics.electricPower.E[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] (0.0 = $START.modelStatistics.electricPower.E[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] (0.0 = $START.modelStatistics.electricPower.E[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] (0.0 = $START.modelStatistics.electricPower.E[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] (0.0 = $START.modelStatistics.electricPower.E[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] (0.0 = $START.modelStatistics.electricPower.E[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[8]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[7]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[9]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE_heat[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[14]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[13]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[12]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[11]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] (0.0 = $START.modelStatistics.gwpEmissions.m_CDE[10]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectElectricPower.E = $START.valveAndCompressor_dp.compressor.collectElectricPower.E (0.0 = $START.valveAndCompressor_dp.compressor.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectElectricPower.E = $START.valveAndCompressor_mflow.compressor.collectElectricPower.E (0.0 = $START.valveAndCompressor_mflow.compressor.collectElectricPower.E) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.m_CDE_consumed = $START.valveAndCompressor_dp1.compressor.collectCosts.m_CDE_consumed (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp1.compressor.collectCosts.m_CDE_produced = $START.valveAndCompressor_dp1.compressor.collectCosts.m_CDE_produced (0.0 = $START.valveAndCompressor_dp1.compressor.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] (0.0 = $START.modelStatistics.electricPower.negSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] (0.0 = $START.modelStatistics.electricPower.negSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] (0.0 = $START.modelStatistics.electricPower.negSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] (0.0 = $START.modelStatistics.electricPower.negSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] (0.0 = $START.modelStatistics.electricPower.negSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] (0.0 = $START.modelStatistics.electricPower.negSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] (0.0 = $START.modelStatistics.electricPower.posSBE[6]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] (0.0 = $START.modelStatistics.electricPower.posSBE[5]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] (0.0 = $START.modelStatistics.electricPower.posSBE[4]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] (0.0 = $START.modelStatistics.electricPower.posSBE[3]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] (0.0 = $START.modelStatistics.electricPower.posSBE[2]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] (0.0 = $START.modelStatistics.electricPower.posSBE[1]) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos (0.0 = $START.modelStatistics.electricPower.E_residual_pos) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg (0.0 = $START.modelStatistics.electricPower.E_residual_neg) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.m_CDE_consumed = $START.valveAndCompressor_dp.compressor.collectCosts.m_CDE_consumed (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_dp.compressor.collectCosts.m_CDE_produced = $START.valveAndCompressor_dp.compressor.collectCosts.m_CDE_produced (0.0 = $START.valveAndCompressor_dp.compressor.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.m_CDE_consumed = $START.storage1.storage.collectCosts_Storage.m_CDE_consumed (0.0 = $START.storage1.storage.collectCosts_Storage.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage1.storage.collectCosts_Storage.m_CDE_produced = $START.storage1.storage.collectCosts_Storage.m_CDE_produced (0.0 = $START.storage1.storage.collectCosts_Storage.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.m_CDE_consumed = $START.valveAndCompressor_mflow.compressor.collectCosts.m_CDE_consumed (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: valveAndCompressor_mflow.compressor.collectCosts.m_CDE_produced = $START.valveAndCompressor_mflow.compressor.collectCosts.m_CDE_produced (0.0 = $START.valveAndCompressor_mflow.compressor.collectCosts.m_CDE_produced) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.m_CDE_consumed = $START.storage.storage.collectCosts_Storage.m_CDE_consumed (0.0 = $START.storage.storage.collectCosts_Storage.m_CDE_consumed) Warning: It was not possible to determine if the initialization problem is consistent, because of not evaluable parameters/start values during compile time: storage.storage.collectCosts_Storage.m_CDE_produced = $START.storage.storage.collectCosts_Storage.m_CDE_produced (0.0 = $START.storage.storage.collectCosts_Storage.m_CDE_produced) Notification: Performance of analyzeInitialSystem (initialization): time 0.3498/7.039, allocations: 158.5 MB / 4.62 GB, free: 112.2 MB / 2.108 GB Notification: Performance of solveInitialSystemEqSystem (initialization): time 0.0004101/7.04, allocations: 80 kB / 4.62 GB, free: 112.1 MB / 2.108 GB Notification: Performance of matching and sorting (n=3661) (initialization): time 0.09308/7.133, allocations: 44.95 MB / 4.664 GB, free: 67.06 MB / 2.108 GB Notification: Performance of prepare postOptimizeDAE: time 0.0006156/7.134, allocations: 132.2 kB / 4.664 GB, free: 66.93 MB / 2.108 GB Notification: Performance of postOpt simplifyComplexFunction (initialization): time 0.002321/7.136, allocations: 0.7418 MB / 4.665 GB, free: 66.19 MB / 2.108 GB Notification: Performance of postOpt tearingSystem (initialization): time 0.01174/7.148, allocations: 3.702 MB / 4.669 GB, free: 62.48 MB / 2.108 GB Notification: Performance of postOpt solveSimpleEquations (initialization): time 0.02826/7.176, allocations: 4.312 MB / 4.673 GB, free: 58.16 MB / 2.108 GB Notification: Performance of postOpt calculateStrongComponentJacobians (initialization): time 0.03008/7.206, allocations: 28.74 MB / 4.701 GB, free: 28.47 MB / 2.108 GB Notification: Performance of postOpt simplifyAllExpressions (initialization): time 0.02553/7.232, allocations: 0.8809 MB / 4.702 GB, free: 27.59 MB / 2.108 GB Notification: Performance of postOpt collapseArrayExpressions (initialization): time 0.006772/7.239, allocations: 1.129 MB / 4.703 GB, free: 26.46 MB / 2.108 GB Warning: Assuming fixed start value for the following 5 variables: valveAndCompressor_mflow.junction.h:VARIABLE(start = valveAndCompressor_mflow.junction.h_start unit = "J/kg" fixed = true protected = true ) "Specific enthalpy" type: Real valveAndCompressor_dp.junction.h:VARIABLE(start = valveAndCompressor_dp.junction.h_start unit = "J/kg" fixed = true protected = true ) "Specific enthalpy" type: Real valveAndCompressor_dp.split.h:VARIABLE(start = valveAndCompressor_dp.split.h_start unit = "J/kg" fixed = true protected = true ) "Specific enthalpy" type: Real valveAndCompressor_dp1.junction.h:VARIABLE(start = valveAndCompressor_dp1.junction.h_start unit = "J/kg" fixed = true protected = true ) "Specific enthalpy" type: Real valveAndCompressor_dp1.split.h:VARIABLE(start = valveAndCompressor_dp1.split.h_start unit = "J/kg" fixed = true protected = true ) "Specific enthalpy" type: Real Warning: The initial conditions are over specified. The following 115 initial equations are redundant, so they are removed from the initialization system: valveAndCompressor_dp1.compressor.collectCosts.other_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.other_demand valveAndCompressor_dp1.compressor.collectCosts.other_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.other_revenue valveAndCompressor_dp1.compressor.collectCosts.H_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.H_demand valveAndCompressor_dp1.compressor.collectCosts.H_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.H_revenue valveAndCompressor_dp1.compressor.collectCosts.Q_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.Q_demand valveAndCompressor_dp1.compressor.collectCosts.Q_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.Q_revenue valveAndCompressor_dp1.compressor.collectCosts.W_el_demand = $START.valveAndCompressor_dp1.compressor.collectCosts.W_el_demand valveAndCompressor_dp1.compressor.collectCosts.W_el_revenue = $START.valveAndCompressor_dp1.compressor.collectCosts.W_el_revenue valveAndCompressor_dp.compressor.collectCosts.other_demand = $START.valveAndCompressor_dp.compressor.collectCosts.other_demand valveAndCompressor_dp.compressor.collectCosts.other_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.other_revenue valveAndCompressor_dp.compressor.collectCosts.H_demand = $START.valveAndCompressor_dp.compressor.collectCosts.H_demand valveAndCompressor_dp.compressor.collectCosts.H_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.H_revenue valveAndCompressor_dp.compressor.collectCosts.Q_demand = $START.valveAndCompressor_dp.compressor.collectCosts.Q_demand valveAndCompressor_dp.compressor.collectCosts.Q_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.Q_revenue valveAndCompressor_dp.compressor.collectCosts.W_el_demand = $START.valveAndCompressor_dp.compressor.collectCosts.W_el_demand valveAndCompressor_dp.compressor.collectCosts.W_el_revenue = $START.valveAndCompressor_dp.compressor.collectCosts.W_el_revenue storage1.storage.collectCosts_Storage.other_demand = $START.storage1.storage.collectCosts_Storage.other_demand storage1.storage.collectCosts_Storage.other_revenue = $START.storage1.storage.collectCosts_Storage.other_revenue storage1.storage.collectCosts_Storage.H_demand = $START.storage1.storage.collectCosts_Storage.H_demand storage1.storage.collectCosts_Storage.H_revenue = $START.storage1.storage.collectCosts_Storage.H_revenue storage1.storage.collectCosts_Storage.Q_demand = $START.storage1.storage.collectCosts_Storage.Q_demand storage1.storage.collectCosts_Storage.Q_revenue = $START.storage1.storage.collectCosts_Storage.Q_revenue storage1.storage.collectCosts_Storage.W_el_demand = $START.storage1.storage.collectCosts_Storage.W_el_demand storage1.storage.collectCosts_Storage.W_el_revenue = $START.storage1.storage.collectCosts_Storage.W_el_revenue valveAndCompressor_mflow.compressor.collectCosts.other_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.other_demand valveAndCompressor_mflow.compressor.collectCosts.other_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.other_revenue valveAndCompressor_mflow.compressor.collectCosts.H_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.H_demand valveAndCompressor_mflow.compressor.collectCosts.H_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.H_revenue valveAndCompressor_mflow.compressor.collectCosts.Q_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.Q_demand valveAndCompressor_mflow.compressor.collectCosts.Q_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.Q_revenue valveAndCompressor_mflow.compressor.collectCosts.W_el_demand = $START.valveAndCompressor_mflow.compressor.collectCosts.W_el_demand valveAndCompressor_mflow.compressor.collectCosts.W_el_revenue = $START.valveAndCompressor_mflow.compressor.collectCosts.W_el_revenue storage.storage.collectCosts_Storage.other_demand = $START.storage.storage.collectCosts_Storage.other_demand storage.storage.collectCosts_Storage.other_revenue = $START.storage.storage.collectCosts_Storage.other_revenue storage.storage.collectCosts_Storage.H_demand = $START.storage.storage.collectCosts_Storage.H_demand storage.storage.collectCosts_Storage.H_revenue = $START.storage.storage.collectCosts_Storage.H_revenue storage.storage.collectCosts_Storage.Q_demand = $START.storage.storage.collectCosts_Storage.Q_demand storage.storage.collectCosts_Storage.Q_revenue = $START.storage.storage.collectCosts_Storage.Q_revenue storage.storage.collectCosts_Storage.W_el_demand = $START.storage.storage.collectCosts_Storage.W_el_demand storage.storage.collectCosts_Storage.W_el_revenue = $START.storage.storage.collectCosts_Storage.W_el_revenue valveAndCompressor_dp1.compressor.collectElectricPower.E = $START.valveAndCompressor_dp1.compressor.collectElectricPower.E modelStatistics.heatingPower.E[6] = $START.modelStatistics.heatingPower.E[6] modelStatistics.heatingPower.E[4] = $START.modelStatistics.heatingPower.E[4] modelStatistics.heatingPower.E[3] = $START.modelStatistics.heatingPower.E[3] modelStatistics.heatingPower.E[2] = $START.modelStatistics.heatingPower.E[2] modelStatistics.heatingPower.E[1] = $START.modelStatistics.heatingPower.E[1] modelStatistics.heatingPower.E[5] = $START.modelStatistics.heatingPower.E[5] modelStatistics.electricPower.negPBE[6] = $START.modelStatistics.electricPower.negPBE[6] modelStatistics.electricPower.negPBE[5] = $START.modelStatistics.electricPower.negPBE[5] modelStatistics.electricPower.negPBE[4] = $START.modelStatistics.electricPower.negPBE[4] modelStatistics.electricPower.negPBE[3] = $START.modelStatistics.electricPower.negPBE[3] modelStatistics.electricPower.negPBE[2] = $START.modelStatistics.electricPower.negPBE[2] modelStatistics.electricPower.negPBE[1] = $START.modelStatistics.electricPower.negPBE[1] modelStatistics.electricPower.posPBE[6] = $START.modelStatistics.electricPower.posPBE[6] modelStatistics.electricPower.posPBE[5] = $START.modelStatistics.electricPower.posPBE[5] modelStatistics.electricPower.posPBE[4] = $START.modelStatistics.electricPower.posPBE[4] modelStatistics.electricPower.posPBE[3] = $START.modelStatistics.electricPower.posPBE[3] modelStatistics.electricPower.posPBE[2] = $START.modelStatistics.electricPower.posPBE[2] modelStatistics.electricPower.posPBE[1] = $START.modelStatistics.electricPower.posPBE[1] modelStatistics.electricPower.E[4] = $START.modelStatistics.electricPower.E[4] modelStatistics.electricPower.E[3] = $START.modelStatistics.electricPower.E[3] modelStatistics.electricPower.E[2] = $START.modelStatistics.electricPower.E[2] modelStatistics.electricPower.E[1] = $START.modelStatistics.electricPower.E[1] modelStatistics.electricPower.E[6] = $START.modelStatistics.electricPower.E[6] modelStatistics.electricPower.E[5] = $START.modelStatistics.electricPower.E[5] modelStatistics.gwpEmissions.m_CDE_heat[10] = $START.modelStatistics.gwpEmissions.m_CDE_heat[10] modelStatistics.gwpEmissions.m_CDE_heat[8] = $START.modelStatistics.gwpEmissions.m_CDE_heat[8] modelStatistics.gwpEmissions.m_CDE_heat[7] = $START.modelStatistics.gwpEmissions.m_CDE_heat[7] modelStatistics.gwpEmissions.m_CDE_heat[6] = $START.modelStatistics.gwpEmissions.m_CDE_heat[6] modelStatistics.gwpEmissions.m_CDE_heat[5] = $START.modelStatistics.gwpEmissions.m_CDE_heat[5] modelStatistics.gwpEmissions.m_CDE_heat[4] = $START.modelStatistics.gwpEmissions.m_CDE_heat[4] modelStatistics.gwpEmissions.m_CDE_heat[3] = $START.modelStatistics.gwpEmissions.m_CDE_heat[3] modelStatistics.gwpEmissions.m_CDE[9] = $START.modelStatistics.gwpEmissions.m_CDE[9] modelStatistics.gwpEmissions.m_CDE[8] = $START.modelStatistics.gwpEmissions.m_CDE[8] modelStatistics.gwpEmissions.m_CDE[7] = $START.modelStatistics.gwpEmissions.m_CDE[7] modelStatistics.gwpEmissions.m_CDE[6] = $START.modelStatistics.gwpEmissions.m_CDE[6] modelStatistics.gwpEmissions.m_CDE[5] = $START.modelStatistics.gwpEmissions.m_CDE[5] modelStatistics.gwpEmissions.m_CDE[4] = $START.modelStatistics.gwpEmissions.m_CDE[4] modelStatistics.gwpEmissions.m_CDE[3] = $START.modelStatistics.gwpEmissions.m_CDE[3] modelStatistics.gwpEmissions.m_CDE[2] = $START.modelStatistics.gwpEmissions.m_CDE[2] modelStatistics.gwpEmissions.m_CDE[1] = $START.modelStatistics.gwpEmissions.m_CDE[1] modelStatistics.gwpEmissions.m_CDE_heat[9] = $START.modelStatistics.gwpEmissions.m_CDE_heat[9] modelStatistics.gwpEmissions.m_CDE_heat[2] = $START.modelStatistics.gwpEmissions.m_CDE_heat[2] modelStatistics.gwpEmissions.m_CDE_heat[1] = $START.modelStatistics.gwpEmissions.m_CDE_heat[1] modelStatistics.gwpEmissions.m_CDE[14] = $START.modelStatistics.gwpEmissions.m_CDE[14] modelStatistics.gwpEmissions.m_CDE[13] = $START.modelStatistics.gwpEmissions.m_CDE[13] modelStatistics.gwpEmissions.m_CDE[12] = $START.modelStatistics.gwpEmissions.m_CDE[12] modelStatistics.gwpEmissions.m_CDE[11] = $START.modelStatistics.gwpEmissions.m_CDE[11] modelStatistics.gwpEmissions.m_CDE[10] = $START.modelStatistics.gwpEmissions.m_CDE[10] valveAndCompressor_dp.compressor.collectElectricPower.E = $START.valveAndCompressor_dp.compressor.collectElectricPower.E valveAndCompressor_mflow.compressor.collectElectricPower.E = $START.valveAndCompressor_mflow.compressor.collectElectricPower.E valveAndCompressor_dp1.compressor.collectCosts.m_CDE_consumed = $START.valveAndCompressor_dp1.compressor.collectCosts.m_CDE_consumed valveAndCompressor_dp1.compressor.collectCosts.m_CDE_produced = $START.valveAndCompressor_dp1.compressor.collectCosts.m_CDE_produced modelStatistics.electricPower.negSBE[6] = $START.modelStatistics.electricPower.negSBE[6] modelStatistics.electricPower.negSBE[5] = $START.modelStatistics.electricPower.negSBE[5] modelStatistics.electricPower.negSBE[4] = $START.modelStatistics.electricPower.negSBE[4] modelStatistics.electricPower.negSBE[3] = $START.modelStatistics.electricPower.negSBE[3] modelStatistics.electricPower.negSBE[2] = $START.modelStatistics.electricPower.negSBE[2] modelStatistics.electricPower.negSBE[1] = $START.modelStatistics.electricPower.negSBE[1] modelStatistics.electricPower.posSBE[6] = $START.modelStatistics.electricPower.posSBE[6] modelStatistics.electricPower.posSBE[5] = $START.modelStatistics.electricPower.posSBE[5] modelStatistics.electricPower.posSBE[4] = $START.modelStatistics.electricPower.posSBE[4] modelStatistics.electricPower.posSBE[3] = $START.modelStatistics.electricPower.posSBE[3] modelStatistics.electricPower.posSBE[2] = $START.modelStatistics.electricPower.posSBE[2] modelStatistics.electricPower.posSBE[1] = $START.modelStatistics.electricPower.posSBE[1] modelStatistics.electricPower.E_residual_pos = $START.modelStatistics.electricPower.E_residual_pos modelStatistics.electricPower.E_residual_neg = $START.modelStatistics.electricPower.E_residual_neg valveAndCompressor_dp.compressor.collectCosts.m_CDE_consumed = $START.valveAndCompressor_dp.compressor.collectCosts.m_CDE_consumed valveAndCompressor_dp.compressor.collectCosts.m_CDE_produced = $START.valveAndCompressor_dp.compressor.collectCosts.m_CDE_produced storage1.storage.collectCosts_Storage.m_CDE_consumed = $START.storage1.storage.collectCosts_Storage.m_CDE_consumed storage1.storage.collectCosts_Storage.m_CDE_produced = $START.storage1.storage.collectCosts_Storage.m_CDE_produced valveAndCompressor_mflow.compressor.collectCosts.m_CDE_consumed = $START.valveAndCompressor_mflow.compressor.collectCosts.m_CDE_consumed valveAndCompressor_mflow.compressor.collectCosts.m_CDE_produced = $START.valveAndCompressor_mflow.compressor.collectCosts.m_CDE_produced storage.storage.collectCosts_Storage.m_CDE_consumed = $START.storage.storage.collectCosts_Storage.m_CDE_consumed storage.storage.collectCosts_Storage.m_CDE_produced = $START.storage.storage.collectCosts_Storage.m_CDE_produced. Notification: Model statistics after passing the back-end for initialization: * Number of independent subsystems: 1276 * Number of states: 0 () * Number of discrete variables: 18 ($PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$PRE.simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,$PRE.valveAndCompressor_dp1.valve.hysteresis.y,$PRE.valveAndCompressor_dp.valve.hysteresis.y,$PRE.valveAndCompressor_mflow.valve.hysteresis.y,$PRE.valveAndCompressor_mflow.controllerValveOrCompressor.hysteresis.y,valveAndCompressor_dp1.valve.hysteresis.y,valveAndCompressor_dp.valve.hysteresis.y,valveAndCompressor_mflow.valve.hysteresis.y,valveAndCompressor_mflow.controllerValveOrCompressor.hysteresis.y) * Number of discrete states: 0 () * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for initialization (2017): * Single equations (assignments): 1864 * Array equations: 4 * Algorithm blocks: 0 * Record equations: 133 * When equations: 0 * If-equations: 0 * Equation systems (not torn): 10 * Torn equation systems: 6 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 10 systems {1, 1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(1,4,100.0%), (1,4,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 4 systems {(1,21), (2,21), (4,61), (1,3)} Notification: Performance of prepare postOptimizeDAE: time 0.02899/7.268, allocations: 10.81 MB / 4.714 GB, free: 15.5 MB / 2.108 GB Notification: Performance of postOpt lateInlineFunction (simulation): time 0.01044/7.278, allocations: 3.025 MB / 4.717 GB, free: 12.43 MB / 2.108 GB Notification: Performance of postOpt wrapFunctionCalls (simulation): time 0.08882/7.367, allocations: 36.46 MB / 4.752 GB, free: 7.922 MB / 2.139 GB Notification: Performance of postOpt inlineArrayEqn (simulation): time 0.0004162/7.367, allocations: 132 kB / 4.752 GB, free: 7.793 MB / 2.139 GB Notification: Performance of postOpt constantLinearSystem (simulation): time 6.973e-05/7.367, allocations: 12 kB / 4.752 GB, free: 7.781 MB / 2.139 GB Notification: Performance of postOpt simplifysemiLinear (simulation): time 0.0002519/7.368, allocations: 51.84 kB / 4.752 GB, free: 7.73 MB / 2.139 GB Notification: Performance of postOpt removeSimpleEquations (simulation): time 0.1737/7.541, allocations: 70.13 MB / 4.821 GB, free: 1.602 MB / 2.202 GB Notification: Performance of postOpt simplifyComplexFunction (simulation): time 0.001864/7.543, allocations: 491.6 kB / 4.821 GB, free: 1.121 MB / 2.202 GB Notification: Performance of postOpt solveSimpleEquations (simulation): time 0.02175/7.565, allocations: 1.919 MB / 4.823 GB, free: 15.2 MB / 2.217 GB Notification: Performance of postOpt tearingSystem (simulation): time 0.01261/7.578, allocations: 3.259 MB / 4.826 GB, free: 11.93 MB / 2.217 GB Notification: Performance of postOpt inputDerivativesUsed (simulation): time 0.00474/7.583, allocations: 347.8 kB / 4.827 GB, free: 11.59 MB / 2.217 GB Notification: Performance of postOpt calculateStrongComponentJacobians (simulation): time 0.04423/7.627, allocations: 30.47 MB / 4.856 GB, free: 12.11 MB / 2.249 GB Notification: Performance of postOpt calculateStateSetsJacobians (simulation): time 2.985e-05/7.627, allocations: 24 kB / 4.856 GB, free: 12.08 MB / 2.249 GB Notification: Performance of postOpt symbolicJacobian (simulation): time 0.1434/7.77, allocations: 54.4 MB / 4.91 GB, free: 5.277 MB / 2.295 GB Notification: Performance of postOpt removeConstants (simulation): time 0.02332/7.794, allocations: 6.893 MB / 4.916 GB, free: 14.32 MB / 2.311 GB Notification: Performance of postOpt simplifyTimeIndepFuncCalls (simulation): time 0.01072/7.805, allocations: 215.8 kB / 4.917 GB, free: 14.11 MB / 2.311 GB Notification: Performance of postOpt simplifyAllExpressions (simulation): time 0.01716/7.822, allocations: 363.7 kB / 4.917 GB, free: 13.76 MB / 2.311 GB Notification: Performance of postOpt findZeroCrossings (simulation): time 0.005367/7.827, allocations: 0.6725 MB / 4.918 GB, free: 13.08 MB / 2.311 GB Notification: Performance of postOpt collapseArrayExpressions (simulation): time 0.004387/7.832, allocations: 475.8 kB / 4.918 GB, free: 12.62 MB / 2.311 GB Notification: Performance of sorting global known variables: time 1.414/9.245, allocations: 20.5 MB / 4.938 GB, free: 0.7633 GB / 2.327 GB Notification: Performance of sort global known variables: time 1.042e-06/9.245, allocations: 2.906 kB / 4.938 GB, free: 0.7633 GB / 2.327 GB Notification: Performance of remove unused functions: time 0.04241/9.288, allocations: 5.674 MB / 4.944 GB, free: 0.7633 GB / 2.327 GB Notification: Model statistics after passing the back-end for simulation: * Number of independent subsystems: 64 * Number of states: 38 (storage.storage.h_gas,storage.cylindricalWall.U[1],storage.topBottomWall.U[1],valveAndCompressor_mflow.junction.gasBulk.xi[1],valveAndCompressor_mflow.junction.gasBulk.xi[2],valveAndCompressor_mflow.junction.gasBulk.xi[3],valveAndCompressor_mflow.junction.gasBulk.xi[4],valveAndCompressor_mflow.junction.gasBulk.xi[5],valveAndCompressor_mflow.junction.gasBulk.xi[6],valveAndCompressor_mflow.junction.h,valveAndCompressor_mflow.split.gasBulk.xi[1],valveAndCompressor_mflow.split.gasBulk.xi[2],valveAndCompressor_mflow.split.gasBulk.xi[3],valveAndCompressor_mflow.split.gasBulk.xi[4],valveAndCompressor_mflow.split.gasBulk.xi[5],valveAndCompressor_mflow.split.gasBulk.xi[6],valveAndCompressor_mflow.split.h,valveAndCompressor_mflow.split.p,storage1.storage.h_gas,storage1.cylindricalWall.U[1],storage1.topBottomWall.U[1],valveAndCompressor_dp.junction.gasBulk.xi[1],valveAndCompressor_dp.junction.gasBulk.xi[2],valveAndCompressor_dp.junction.gasBulk.xi[3],valveAndCompressor_dp.junction.gasBulk.xi[4],valveAndCompressor_dp.junction.gasBulk.xi[5],valveAndCompressor_dp.junction.gasBulk.xi[6],valveAndCompressor_dp.junction.h,valveAndCompressor_dp.split.gasBulk.xi[1],valveAndCompressor_dp.split.gasBulk.xi[2],valveAndCompressor_dp.split.gasBulk.xi[3],valveAndCompressor_dp.split.gasBulk.xi[4],valveAndCompressor_dp.split.gasBulk.xi[5],valveAndCompressor_dp.split.gasBulk.xi[6],valveAndCompressor_dp.split.h,valveAndCompressor_dp.split.p,valveAndCompressor_dp1.junction.h,valveAndCompressor_dp1.split.h) * Number of discrete variables: 10 ($whenCondition1,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,$whenCondition2,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,valveAndCompressor_mflow.controllerValveOrCompressor.hysteresis.y,valveAndCompressor_mflow.valve.hysteresis.y,valveAndCompressor_dp.valve.hysteresis.y,valveAndCompressor_dp1.valve.hysteresis.y) * Number of discrete states: 8 (valveAndCompressor_dp1.valve.hysteresis.y,valveAndCompressor_dp.valve.hysteresis.y,valveAndCompressor_mflow.valve.hysteresis.y,valveAndCompressor_mflow.controllerValveOrCompressor.hysteresis.y,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEventScaled,simCenter.electricityPrice.MSL_combiTimeTable.nextTimeEvent,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEventScaled,simCenter.Variable_Ground_Temperature.MSL_combiTimeTable.nextTimeEvent) * Number of clocked states: 0 () * Top-level inputs: 0 Notification: Strong component statistics for simulation (707): * Single equations (assignments): 554 * Array equations: 0 * Algorithm blocks: 0 * Record equations: 134 * When equations: 4 * If-equations: 0 * Equation systems (not torn): 9 * Torn equation systems: 6 * Mixed (continuous/discrete) equation systems: 0 Notification: Equation system details (not torn): * Constant Jacobian (size): 0 systems * Linear Jacobian (size,density): 0 systems * Non-linear Jacobian (size): 9 systems {1, 1, 1, 1, 1, 1, 1, 1, 1} * Without analytic Jacobian (size): 0 systems Notification: Torn system details for strict tearing set: * Linear torn systems (#iteration vars, #inner vars, density): 2 systems {(1,4,100.0%), (1,4,100.0%)} * Non-linear torn systems (#iteration vars, #inner vars): 4 systems {(1,21), (2,24), (3,62), (1,3)} [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:119:25-120:61:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so [/home/hudson/saved_omc/libraries/.openmodelica/libraries/TILMedia 1.8.1-main/Internals/VLEFluidConfigurations/FullyMixtureCompatible/VLEFluid.mo:121:25-122:60:writable] Warning: Could not find library TILMedia181ClaRa in either of: /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /lib/x86_64-linux-gnu/libTILMedia181ClaRa.a /usr/lib//libTILMedia181ClaRa.a /lib//libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.a /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.a /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /usr/lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /lib/x86_64-linux-gnu/libTILMedia181ClaRa.so /usr/lib//libTILMedia181ClaRa.so /lib//libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib/x86_64-linux-gnu/omc/libTILMedia181ClaRa.so /var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../lib//libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/binaries/TransiEnt/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/x86_64-linux/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/linux64/libTILMedia181ClaRa.so /home/hudson/saved_omc/libraries/.openmodelica/libraries/TransiEnt 2.0.2-master/Resources/Library/libTILMedia181ClaRa.so Notification: Performance of Backend phase and start with SimCode phase: time 0.008825/9.297, allocations: 1.709 MB / 4.945 GB, free: 0.7631 GB / 2.327 GB Notification: Performance of simCode: created initialization part: time 0.08784/9.385, allocations: 42.65 MB / 4.987 GB, free: 0.7452 GB / 2.327 GB Notification: Performance of simCode: created event and clocks part: time 3.46e-05/9.385, allocations: 3.031 kB / 4.987 GB, free: 0.7452 GB / 2.327 GB Notification: Performance of simCode: created simulation system equations: time 0.04285/9.427, allocations: 23.54 MB / 5.01 GB, free: 0.7319 GB / 2.327 GB Notification: Performance of simCode: created of all other equations (e.g. parameter, nominal, assert, etc): time 0.05987/9.487, allocations: 6.72 MB / 5.016 GB, free: 0.7298 GB / 2.327 GB Warning: The hideResult annotation could not be evaluated, probably due to missing annotation(Evaluate=true). It is removed. Notification: Performance of simCode: created linear, non-linear and system jacobian parts: time 0.1637/9.651, allocations: 70.33 MB / 5.085 GB, free: 0.6978 GB / 2.327 GB Notification: Performance of simCode: some other stuff during SimCode phase: time 0.04251/9.694, allocations: 15.82 MB / 5.101 GB, free: 0.6901 GB / 2.327 GB Notification: Performance of simCode: all other stuff during SimCode phase: time 0.01422/9.708, allocations: 2.061 MB / 5.103 GB, free: 0.6887 GB / 2.327 GB Notification: Performance of SimCode: time 1.102e-06/9.708, allocations: 0 / 5.103 GB, free: 0.6887 GB / 2.327 GB Notification: Performance of Templates: time 6.899/16.61, allocations: 2.532 GB / 7.634 GB, free: 0.7887 GB / 2.389 GB make -j1 -f TransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor.makefile make -j1 -f TransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressor.makefile clang++ -std=c++17 -fopenmp=libomp -Winvalid-pch -O2 -g -DNDEBUG -fPIC -std=c++11 -DBOOST_ALL_DYN_LINK -DUSE_DGESV -DUSE_LOGGER -DOMC_BUILD -DUSE_THREAD -DSUNDIALS_MAJOR_VERSION=5 -DSUNDIALS_MINOR_VERSION=4 -DPMC_USE_SUNDIALS -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/bin/../include/omc/cpp/" -I. "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -I"." -I"." -I"/var/lib/jenkins1/ws/OpenModelicaLibraryTestingWork/OpenModelica/OMCompiler/build/include/omc/sundials" "-I/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/Resources/C-Sources" -DMEASURETIME_PROFILEBLOCKS -DUSE_LOGGER -c -o OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorCalcHelperMain.o OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorCalcHelperMain.cpp In file included from OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorCalcHelperMain.cpp:28: ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1226:25: error: no matching function for call to 'TILMedia_createExternalObject' externalObject__ext = TILMedia_createExternalObject(objectType_.c_str(), mediumName_.c_str(), flags__ext, ConstArray(xi_).getData(), nc__ext, condensingIndex__ext, instanceName_.c_str()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:44:7: note: candidate function not viable: 4th argument ('const double *') would lose const qualifier void* TILMedia_createExternalObject(const char* objectType, const char* mixtureName, int flags, double* xi, int _nc, int condensingIndex, const char* instanceName) { ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1271:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_density_pTxi' d__ext = TILMedia_VLEFluidObjectFunctions_density_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:18:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_density_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1297:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_density_phxi' d__ext = TILMedia_VLEFluid_Cached_density_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:17:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_density_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1323:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:16:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1349:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:15:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1375:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi' s__ext = TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:14:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_specificEntropy_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1401:12: error: no matching function for call to 'TILMedia_VLEFluidObjectFunctions_temperature_phxi' T__ext = TILMedia_VLEFluidObjectFunctions_temperature_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:13:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidObjectFunctions_temperature_phxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1427:12: error: no matching function for call to 'TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidName_.c_str(), nc__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:12:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluidFunctions_specificEnthalpy_pTxi(double, double, double*,const char*, int); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1502:3: error: no matching function for call to 'TILMedia_VLEFluid_VLEProperties_phxi' TILMedia_VLEFluid_VLEProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &d_l__ext, &h_l__ext, &p_l__ext, &s_l__ext, &T_l__ext, xi_l_.getData(), &d_v__ext, &h_v__ext, &p_v__ext, &s_v__ext, &T_v__ext, xi_v_.getData()); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:10:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_VLEProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1599:3: error: no matching function for call to 'TILMedia_VLEFluid_additionalProperties_phxi' TILMedia_VLEFluid_additionalProperties_phxi(p__ext, h__ext, ConstArray(xi_).getData(), vleFluidPointer__ext, &x__ext, &cp__ext, &cv__ext, &beta__ext, &kappa__ext, &drhodp__ext, &drhodh__ext, drhodxi_.getData(), &a__ext, &gamma__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:9:6: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_additionalProperties_phxi(double, double, double*, void*, double*, double*, double*, double*, double*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1666:3: error: no matching function for call to 'TILMedia_VLEFluid_cricondenbar_xi' TILMedia_VLEFluid_cricondenbar_xi(ConstArray(xi_).getData(), vleFluidPointer__ext, &d__ext, &h__ext, &p__ext, &s__ext, &T__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:8:6: note: candidate function not viable: 1st argument ('const double *') would lose const qualifier void TILMedia_VLEFluid_cricondenbar_xi(double*, void*, double*, double*, double*, double*, double*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:1982:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:2008:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:2034:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:2060:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:2086:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi' h__ext = TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:6:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEnthalpy_pTxi(double, double, double*, void*); ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:2112:12: error: no matching function for call to 'TILMedia_VLEFluid_Cached_specificEntropy_pTxi' s__ext = TILMedia_VLEFluid_Cached_specificEntropy_pTxi(p__ext, T__ext, ConstArray(xi_).getData(), vleFluidPointer__ext); ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorFunctions.cpp:5:8: note: candidate function not viable: 3rd argument ('const double *') would lose const qualifier double TILMedia_VLEFluid_Cached_specificEntropy_pTxi(double, double, double*, void*); ^ In file included from OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorCalcHelperMain.cpp:29: ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorInitialize.cpp:10448:29: error: use of undeclared identifier '_storage_P_storage_P_medium_P_fixedMixingRatio_' tmp99.fixedMixingRatio_ = _storage_P_storage_P_medium_P_fixedMixingRatio_; ^ ./OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorInitialize.cpp:10449:35: error: use of undeclared identifier '_storage_P_storage_P_medium_P_nc_propertyCalculation_' tmp99.nc_propertyCalculation_ = _storage_P_storage_P_medium_P_nc_propertyCalculation_; ^ fatal error: too many errors emitted, stopping now [-ferror-limit=] 20 errors generated. make: *** [: OMCppTransiEnt_TransiEnt.Components.Gas.Compressor.Check.TestValveAndCompressorCalcHelperMain.o] Error 1