Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo", uses=false) Using package IndustrialControlSystems with version 1.1.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo) Using package Modelica with version 3.2.3 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode") translateModel(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode,tolerance=1e-06,outputFormat="empty",numberOfIntervals=5000,variableFilter="",fileNamePrefix="IndustrialControlSystems_IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.001163/0.001163, allocations: 107.7 kB / 16.41 MB, free: 6.473 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.00108/0.00108, allocations: 185.6 kB / 17.34 MB, free: 5.75 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 3.2.3+maint.om/package.mo): time 1.418/1.418, allocations: 205.1 MB / 223.2 MB, free: 12.24 MB / 190.1 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/package.mo): time 0.05835/0.05835, allocations: 10.73 MB / 281.3 MB, free: 1.305 MB / 222.1 MB Notification: Modelica requested package Complex of version 3.2.3. Complex 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Modelica requested package ModelicaServices of version 3.2.3. ModelicaServices 4.0.0 is used instead which states that it is fully compatible without conversion script needed. Notification: Performance of FrontEnd - loaded program: time 0.001477/0.001477, allocations: 76.06 kB / 391.5 MB, free: 46.02 MB / 318.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.0947/0.09619, allocations: 49.03 MB / 440.5 MB, free: 3.824 MB / 318.1 MB Notification: Performance of NFInst.instantiate(IndustrialControlSystems.Controllers.AutoTuning.Examples.Test_ATPIrelayNCmixedMode): time 0.003694/0.09994, allocations: 3.191 MB / 443.7 MB, free: 0.6055 MB / 318.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/IndustrialControlSystems 1.1.0-master/Controllers/AutoTuning/ATPIrelayNCmixedMode.mo:91:8-91:29:writable] Error: Operator reinit may not be used in an algorithm section (use translation flag --allowNonStandardModelica=reinitInAlgorithms to ignore). Notification: Performance of FrontEnd: time 0.0002991/0.1003, allocations: 171.8 kB / 443.9 MB, free: 448 kB / 318.1 MB