Running: ./testmodel.py --libraries=/home/hudson/saved_omc/libraries/.openmodelica/libraries --ompython_omhome=/usr BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler.conf.json loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo", uses=false) loadFile("/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo", uses=false) Using package BuildSysPro with version 3.5.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo) Using package Modelica with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo) Using package Complex with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo) Using package ModelicaServices with version 4.0.0 (/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo) Running command: translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") translateModel(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler,tolerance=1e-06,outputFormat="empty",numberOfIntervals=16,variableFilter="",fileNamePrefix="BuildSysPro_BuildSysPro.Systems.HVAC.Production.Boiler.Boiler") Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/ModelicaServices 4.0.0+maint.om/package.mo): time 0.00122/0.00122, allocations: 111.9 kB / 16.41 MB, free: 6.469 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Complex 4.0.0+maint.om/package.mo): time 0.001198/0.001198, allocations: 189.7 kB / 17.34 MB, free: 5.715 MB / 14.72 MB Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/Modelica 4.0.0+maint.om/package.mo): time 1.241/1.241, allocations: 222.9 MB / 241 MB, free: 15.14 MB / 206.1 MB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/Building/BuildingEnvelope/HeatTransfer/package.mo:2:1-40:17:writable] Warning: Soil_case_nappe was referenced in the package.order file, but was not found in package.mo, Soil_case_nappe/package.mo or Soil_case_nappe.mo. Notification: Performance of loadFile(/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/package.mo): time 0.8021/0.8021, allocations: 143.1 MB / 434.3 MB, free: 11.96 MB / 350.1 MB Notification: Performance of FrontEnd - loaded program: time 0.001112/0.001112, allocations: 69.27 kB / 0.5961 GB, free: 12.49 MB / 446.1 MB Notification: Performance of FrontEnd - Absyn->SCode: time 0.1435/0.1446, allocations: 82.02 MB / 0.6762 GB, free: 10.56 MB / 0.5137 GB Notification: Performance of NFInst.instantiate(BuildSysPro.Systems.HVAC.Production.Boiler.Boiler): time 0.003297/0.1479, allocations: 2.323 MB / 0.6785 GB, free: 8.227 MB / 0.5137 GB [/home/hudson/saved_omc/libraries/.openmodelica/libraries/BuildSysPro 3.6.0/BaseClasses/Media/OLD_THERMHYGAERO/AirFunctions/Psat.mo:3:3-3:24:writable] Error: Invalid public variable AH, function variables that are not input/output must be protected. Notification: Performance of FrontEnd: time 0.0008523/0.1488, allocations: 0.4944 MB / 0.679 GB, free: 7.73 MB / 0.5137 GB